A new actigraph for long-term registration of the duration and intensity of tremor and movement
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Actigraphy, the long-term measurement of human movement with a small solid state recorder, is gaining acceptance as a useful method in many research fields. Currently available actigraphs assess or estimate the movement duration per time interval. However, the output gives no information on movement type or intensity, and cannot be used in subjects suffering from tremor. The present paper describes a new type of actigraph, that has been developed primarily for the long-term evaluation of motor symptoms in Parkinson patients. The device is the first to discriminate tremor from other movements and to assess both duration and intensity of the two types of movement. It is based on a Motorola 68HC805B6 microcontroller and contains: an accelerometer, programmable gain stages, programmable low- and highpass filters, a programmable level comparator, a peak detector, interface circuits, a real time clock, data storage, and control circuitry. The micro-controller performs a period amplitude sequence analysis (PASA) on the conditioned accelerometer signal, and stores four output variables (tremor duration, tremor amplitude, movement duration, and movement amplitude) at the end of programmable time intervals. The analysis of fluctuations in the motor symptoms of, e.g., Parkinson patients using this actigraph can be of great help in the pharmacological management of symptoms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
van Someren, E. J. W., van Gool, W. A., Vonk, B. F. M., Mirmiran, M., Speelman, J. D., Bosch, D. A., & Swaab, D. F. (1993) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(93)90148-r · Cited by 56 · cited 4×
“The variability of these symptoms over the day is considerable [3] and long-term assessment of tremor would be of great help in establishing the right dose and timing of medication.”
BackgroundMethodInfluentialSelf-citation
Cited by
Brain mechanisms of insomnia: new perspectives on causes and consequences
Van Someren, E. J. W. (2021) · Physiological Reviews · doi:10.1152/physrev.00046.2019 · Cited by 543
Self-citationDetection of posture and motion by accelerometry: a validation study in ambulatory monitoring
Foerster, F., Smeja, M., & Fahrenberg, J. (1999) · Computers in Human Behavior · doi:10.1016/s0747-5632(99)00037-0 · Cited by 480
Salarian, A., Russmann, H., Wider, C., Burkhard, P. R., Vingerhoets, F. J. G., & Aminian, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886670 · Cited by 416
Continuous Monitoring of Turning in Patients with Movement Disability
El-Gohary, M., Pearson, S., McNames, J., Mancini, M., Horak, F., Mellone, S., & Chiari, L. (2013) · Sensors · doi:10.3390/s140100356 · Cited by 258
Assessment of Tremor Activity in the Parkinson’s Disease Using a Set of Wearable Sensors
Rigas, G., Tzallas, A. T., Tsipouras, M. G., Bougia, P., Tripoliti, E. E., Baga, D., Fotiadis, D. I., Tsouli, S. G., & Konitsiotis, S. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2182616 · Cited by 241
Metadata
- Authors
- Van Someren, E. J. W., Vonk, B. F. M., Thijssen, W. A., Speelman, J. D., Schuurman, P. R., Mirmiran, M., & Swaab, D. F.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1998-03
- Volume
- 45
- Issue
- 3
- Pages
- 386-395
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2167946814
- Cited by
- 91
- References
- 1
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.