The use of the spatial covariance in computing pericardial potentials
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper investigates the incorporation of the spatial covariance of the pericardial potentials, assumed known a priori as a regularization function, when computing the pericardial potential distribution from observed body surface potentials. The resulting inverse solutions are compared with those using as a regularization function: 1) the norm of the solution, 2) the norm of the surface Laplacian of the solution, as well as with those based on using the truncated singular value decomposition. The study uses a realistic source model to simulate potentials throughout the QRS-interval. This source is placed in an anatomically accurate inhomogeneous volume conductor model of the torso. The use of a single value of the regularization parameter is shown to be feasible: for data incorporating 2% noise, the use of the spatial covariance is demonstrated to result in a relative error over the entire QRS interval as low as 10%. Major errors are demonstrated to result if the effect of the inhomogeneity of the lungs is ignored. The spatial covariance based inverse is shown to be more robust with respect to the perturbations (noise; inhomogeneity) than the other estimators included in this study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solving Least Squares Problems
Lawson, C. L., & Hanson, R. J. (1995) · doi:10.1137/1.9781611971217 · Cited by 7,103
Dale, A. M., & Sereno, M. I. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.2.162 · Cited by 2,003
Cited by
Dynamic Statistical Parametric Mapping
Dale, A. M., Liu, A. K., Fischl, B. R., Buckner, R. L., Belliveau, J. W., Lewine, J. D., & Halgren, E. (2000) · Neuron · doi:10.1016/s0896-6273(00)81138-1 · Cited by 1,787
Geometrical aspects of the interindividual variability of multilead ECG recordings
Hoekema, R., Uijen, G. J. H., & van Oosterom, A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.918594 · Cited by 252
“The method to obtain from the timing of a UDL source is documented in some greater detail in [16].”
BackgroundMethodInfluentialSelf-citationInvestigations of sensitivity and resolution of ECG and MCG in a realistically shaped thorax model
Mäntynen, V., Konttila, T., & Stenroos, M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/23/7141 · Cited by 45
Nenonen, J., Pesola, K., H[auml ]nninen, H., Lauerma, K., Takala, P., M[auml ]kel[auml ], T., M[auml ]kij[auml ]rvi, M., Knuuti, J., Toivonen, L., & Katila, T. (2001) · Journal of Electrocardiology · doi:10.1054/jelc.2001.28824 · Cited by 27
“Different regularization schemes applicable in the cardiac inverse problem have been investigated especially with the epicardial potential equivalent-source model (eg, [3–8]).”
BackgroundCurrent density imaging of focal cardiac sources
Nenonen, J., Pesola, K., Feneici, R., Lauerma, K., Mäkijärvi, M., & Katila, T. (2001) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.2001.46.s2.50 · Cited by 7
Metadata
- Authors
- van Oosterom, A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1999-07
- Volume
- 46
- Issue
- 7
- Pages
- 778-787
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2144278019
- Cited by
- 78
- References
- 2
- FWCI
- 6.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.