The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Force controlled and teleoperated endoscopic grasper for minimally invasive surgery-experimental performance evaluation
Abstract
Minimally invasive surgery generates new user interfaces which create visual and haptic distortion when compared to traditional surgery. In order to regain the tactile and kinesthetic information that is lost, a computerized force feedback endoscopic surgical grasper (FREG) was developed with computer control and a haptic user interface. The system uses standard unmodified grasper shafts and tips. The FREG can control grasping forces either by surgeon teleoperation control, or under software control. The FREG performance was evaluated using an automated palpation function (programmed series of compressions) in which the grasper measures mechanical properties of the grasped materials. The material parameters obtained from measurements showed the ability of the FREG to discriminate between different types of normal soft tissues (small bowel, lung, spleen, liver, colon, and stomach) and different kinds of artificial soft tissue replication materials (latex/silicone) for simulation purposes. In addition, subjective tests of ranking stiffness of silicone materials using the FREG teleoperation mode showed significant improvement in the performance compared to the standard endoscopic grasper. Moreover, the FREG performance was closer to the performance of the human hand than the standard endoscopic grasper. The FREG as a tool incorporating the force feedback teleoperation technology may provide the basis for application in telesurgery, clinical endoscopic surgery, surgical training, and research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
A design framework for teleoperators with kinesthetic feedback
Hannaford, B. (1989) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.88057 · Cited by 926
Self-citationTactual discrimination of softness
Srinivasan, M. A., & LaMotte, R. H. (1995) · Journal of Neurophysiology · doi:10.1152/jn.1995.73.1.88 · Cited by 509
Medicine Meets Virtual Reality 14
(2005) · Computers & Graphics · doi:10.1016/j.cag.2005.09.016 · Cited by 460
Computer-integrated surgery: Technology and clinical applications
(1996) · Computers & Mathematics with Applications · doi:10.1016/s0898-1221(96)90465-4 · Cited by 230
Computer-integrated surgery. Technology and clinical applications. 1996.
Taylor, R. H., Lavelleé, S., Burdea, G., & Mösges, R. (1998) · PubMed · Cited by 218
Localization and Surgical Treatment of Occult Insulinomas
NORTON, J. A., SHAWKER, T. H., DOPPMAN, J. L., MILLER, D. L., FRAKER, D. L., CROMACK, D. T., GORDEN, P., & JENSEN, R. T. (1990) · Annals of Surgery · doi:10.1097/00000658-199011000-00009 · Cited by 172
Bicchi, A., Canepa, G., De Rossi, D., Iacconi, P., & Scillingo, E. P. (2002) · Proceedings of IEEE International Conference on Robotics and Automation · doi:10.1109/robot.1996.503884 · Cited by 169
Force Sensor for Laparoscopic Babcock
Morimoto, A. K., Foral, R. D., Kuhlman, J. L., Zucker, K. A., Curet, M. J., Bocklage, T. J., MacFarlane, T. I., & Kory, L. (1997) · Studies in health technology and informatics · doi:10.3233/978-1-60750-883-0-354 · Cited by 39
Cited by
Medical robotics in computer-integrated surgery
Taylor, R. H., & Stoianovici, D. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817058 · Cited by 997
Force Modeling for Needle Insertion Into Soft Tissue
Okamura, A. M., Simone, C., & O'Leary, M. D. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.831542 · Cited by 830
State-of-the-Art in Force and Tactile Sensing for Minimally Invasive Surgery
Puangmali, P., Althoefer, K., Seneviratne, L. D., Murphy, D., & Dasgupta, P. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2008.917481 · Cited by 588
van der Meijden, O. A. J., & Schijven, M. P. (2009) · Surgical Endoscopy · doi:10.1007/s00464-008-0298-x · Cited by 541
The role of force feedback in surgery: analysis of blunt dissection
Wagner, C. R., Stylopoulos, N., & Howe, R. D. (2005) · Proceedings 10th Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems. HAPTICS 2002 · doi:10.1109/haptic.2002.998943 · Cited by 379
Metadata
- Authors
- Rosen, J., Hannaford, B., MacFarlane, M. P., & Sinanan, M. N.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1999
- Volume
- 46
- Issue
- 10
- Pages
- 1212-1221
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2159349609
- Cited by
- 326
- References
- 9
- FWCI
- 28.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.