The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Aligned microcontact printing of micrometer-scale poly-L-Lysine structures for controlled growth of cultured neurons on planar microelectrode arrays
Abstract
We describe a method for producing high-resolution chemical patterns on surfaces to control the attachment and growth of cultured neurons. Microcontact printing has been extended to allow the printing of micron-scale protein lines aligned to an underlying pattern of planar microelectrodes. Poly-L-lysine (PL) lines have been printed on the electrode array for electrical studies on cultured neural networks. Rat hippocampal neurons showed a high degree of attachment selectivity to the PL and produced neurites that faithfully grew onto the electrode recording sites.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jimbo, Y., Robinson, H. P. C., & Kawana, A. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.238465 · Cited by 192 · cited 1×
“Extracellular substrate electrodes have been used for a variety of neuroscience applications: the correlation of intracellular calcium transients with electrical activity in neural networks [21], stimulation/recording from spinal cord slices and cell networks [22]–[24], detailed evaluations of…”
BackgroundElectrical stimulation and recording from cultured neurons using a planar electrode array
Jimbo, Y., & Kawana, A. (1992) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(92)80067-q · Cited by 126
Cited by
Patolsky, F., Timko, B. P., Yu, G., Fang, Y., Greytak, A. B., Zheng, G., & Lieber, C. M. (2006) · Science · doi:10.1126/science.1128640 · Cited by 832
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Printing meets lithography: Soft approaches to high-resolution patterning
Michel, B., Bernard, A., Bietsch, A., Delamarche, E., Geissler, M., Juncker, D., Kind, H., Renault, J.-P., Rothuizen, H., Schmid, H., et al. (2001) · IBM Journal of Research and Development · doi:10.1147/rd.455.0697 · Cited by 471
Bottom-up strategy of materials fabrication: a new trend in nanotechnology of soft materials
Shimomura, M., & Sawadaishi, T. (2001) · Current Opinion in Colloid & Interface Science · doi:10.1016/s1359-0294(00)00081-9 · Cited by 331
Conformal contact and pattern stability of stamps used for soft lithography
Bietsch, A., & Michel, B. (2000) · Journal of Applied Physics · doi:10.1063/1.1289816 · Cited by 269
Metadata
- Authors
- James, C. D., Davis, R., Meyer, M., Turner, A., Turner, S., Withers, G., Kam, L., Banker, G., Craighead, H., Issacson, M., Turner, J., & Shain, W.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2000
- Volume
- 47
- Issue
- 1
- Pages
- 17-21
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2110014101
- Cited by
- 199
- References
- 2
- FWCI
- 5.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Aligned microcontact printing of micrometer-scale poly-L-Lysine structures for controlled growth of cultured neurons on planar microelectrode arrays. https://app.cochat.ai/papers/10.1109/10.817614
- The paper
- James, C. D., Davis, R., Meyer, M., Turner, A., Turner, S., Withers, G., Kam, L., Banker, G., Craighead, H., Issacson, M., Turner, J., & Shain, W. (2000). Aligned microcontact printing of micrometer-scale poly-L-Lysine structures for controlled growth of cultured neurons on planar microelectrode arrays. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.817614
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.