Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 164

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A micropower dry-electrode ECG preamplifier

Burke, M.J., Gleeson, D.T. · 2000 · IEEE Transactions on Biomedical Engineering

Abstract

This paper describes the development of a very low-power preamplifier intended for use in pasteless-electrode recording of the human electrocardiogram. The expected input signal range is 100 microV-10 mV from a lead-II electrode configuration. The amplifier provides a gain of 43 dB in a 3-dB bandwidth of 0.05 Hz-2 kHz with a defined high input impedance of 75 M omega. It uses a driven common electrode to enhance rejection of common-mode interfering signals, including low-frequency motion artifact, achieving a common-mode rejection ratio (CMRR) of better than 80 dB over its entire bandwidth. The gain and phase characteristics meet the recommendations of the American Heart Association, ensuring low distortion of the output ECG signal and making it suitable for clinical monitoring. The amplifier has a power consumption of 30 microW operating from a 3.3-V battery and is intended for use in small, lightweight, portable electrocardiographic equipment and heart-rate monitoring instrumentation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.821734

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Burke, M. J., & Gleeson, D. T.
Venue
IEEE Transactions on Biomedical Engineering
Published
2000
Volume
47
Issue
2
Pages
155-162
ISSN
0018-9294 (ISSN-L)
OpenAlex
W1978437602
Cited by
164
References
1
FWCI
1.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.