The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition Systems
Open accessAbstract
There is a growing demand for low-power, small-size and ambulatory biopotential acquisition systems. A crucial and important block of this acquisition system is the analog readout front-end. We have implemented a low-power and low-noise readout front-end with configurable characteristics for Electroencephalogram (EEG), Electrocardiogram (ECG), and Electromyogram (EMG) signals. Key to its performance is the new AC-coupled chopped instrumentation amplifier (ACCIA), which uses a low power current feedback instrumentation amplifier (IA). Thus, while chopping filters the 1/f noise of CMOS transistors and increases the CMRR, AC coupling is capable of rejecting differential electrode offset (DEO) up to${\pm}$50 mV from conventional Ag/AgCl electrodes. The ACCIA achieves 120 dB CMRR and 57 nV/$\surd$Hz input-referred voltage noise density, while consuming 11.1$\mu$A from a 3 V supply. The chopping spike filter (CSF) stage filters the chopping spikes generated by the input chopper of ACCIA and the digitally controllable variable gain stage is used to set the gain and the bandwidth of the front-end. The front-end is implemented in a 0.5$\mu$m CMOS process. Total current consumption is 20$\mu$A from 3V.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
A Multiparameter Wearable Physiologic Monitoring System for Space and Terrestrial Applications
Mundt, C. W., Montgomery, K. N., Udoh, U. E., Barker, V. N., Thonier, G. C., Tellier, A. M., Ricks, R. D., Darling, R. B., Cagle, Y. D., Cabrol, N. A., et al. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.854509 · Cited by 226
Cited by
A 1-V 450-nW fully integrated programmable biomedical sensor interface chip.
Zou, X., Xu, X., Yao, L., & Lian, Y. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2014707 · Cited by 414
Implementation of wireless body area networks for healthcare systems
Yuce, M. R. (2010) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2010.06.004 · Cited by 331
Body Area Networks for Ubiquitous Healthcare Applications: Opportunities and Challenges
Jovanov, E., & Milenkovic, A. (2011) · Journal of Medical Systems · doi:10.1007/s10916-011-9661-x · Cited by 183
A 1-V 0.25- $\mu \text{W}$ Inverter Stacking Amplifier With 1.07 Noise Efficiency Factor
Shen, L., Lu, N., & Sun, N. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2786724 · Cited by 101
Multi-Channel Neural Recording Implants: A Review
Hashemi Noshahr, F., Nabavi, M., & Sawan, M. (2020) · Sensors · doi:10.3390/s20030904 · Cited by 66
Metadata
- Authors
- Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2007-05
- Volume
- 42
- Issue
- 5
- Pages
- 1100-1110
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2147498826
- Cited by
- 382
- References
- 2
- FWCI
- 20.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition Systems. https://app.cochat.ai/papers/10.1109/jssc.2007.894804
- The paper
- Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C. (2007). A 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition Systems. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2007.894804
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.