The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Time-frequency analysis of myoelectric signals during dynamic contractions: a comparative study
Abstract
In this paper, we introduce the nonstationary signal analysis methods to analyze the myoelectric (ME) signals during dynamic contractions by estimating the time-dependent spectral moments. The time-frequency analysis methods including the short-time Fourier transform, the Wigner-Ville distribution, the Choi-Williams distribution, and the continuous wavelet transform were compared for estimation accuracy and precision on synthesized and real ME signals. It is found that the estimates provided by the continuous wavelet transform have better accuracy and precision than those obtained with the other time-frequency analysis methods on simulated data sets. In addition, ME signals from four subjects during three different tests (maximum static voluntary contraction, ramp contraction, and repeated isokinetic contractions) were also examined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Габор, Д. (1946) · Journal of the IEE · Cited by 5,036
Time-frequency distributions-a review
Cohen, L. (1989) · Proceedings of the IEEE · doi:10.1109/5.30749 · Cited by 3,571
(2009) · Encyclopedia of Neuroscience · doi:10.1007/978-3-540-29678-2_6014 · Cited by 2,850
Wavelets and signal processing
Rioul, O., & Vetterli, M. (1991) · IEEE Signal Processing Magazine · doi:10.1109/79.91217 · Cited by 2,786
(1996) · Adapted Wavelet Analysis · doi:10.1201/9781439863619-15 · Cited by 2,703
Linear and quadratic time-frequency signal representations
Hlawatsch, F., & Boudreaux-Bartels, G. F. (1992) · IEEE Signal Processing Magazine · doi:10.1109/79.127284 · Cited by 1,632
Improved time-frequency representation of multicomponent signals using exponential kernels
Choi, H.-I., & Williams, W. J. (1989) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/assp.1989.28057 · Cited by 1,299
Muscles Alive. Their Functions Revealed by Electromyography
(1962) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1962.tb19834.x · Cited by 854
Physiology and Mathematics of Myoelectric Signals
De Luca, C. J. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326534 · Cited by 684
Interpretation of myoelectric power spectra: A model and its applications
Lindstrom, L. H., & Magnusson, R. I. (1977) · Proceedings of the IEEE · doi:10.1109/proc.1977.10544 · Cited by 419
Time Frequency and Wavelets in Biomedical Signal Processing
Akay, M. (1997) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470546697 · Cited by 386
Self-citationComputational Signal Processing with Wavelets
Teolis, A. (1998) · Birkhäuser Boston eBooks · doi:10.1007/978-1-4612-4142-3 · Cited by 386
Auditory representations of acoustic signals
Yang, X., Wang, K., & Shamma, S. A. (1992) · IEEE Transactions on Information Theory · doi:10.1109/18.119739 · Cited by 382
Reading and Understanding Continuous Wavelet Transforms
Grossmann, A., Kronland-Martinet, R., & Morlet, J. (1990) · inverse problems and theoretical imaging · doi:10.1007/978-3-642-75988-8_1 · Cited by 312
Isokinetic Dynamometry: Applications and Limitations
Baltzopoulos, V., & Brodie, D. A. (1989) · Sports Medicine · doi:10.2165/00007256-198908020-00003 · Cited by 283
Signal processing and compression with wavelet packets
Coifman, R. R., Meyer, Y., Quake, S., & Wickerhauser, M. V. (1994) · Wavelets and Their Applications · doi:10.1007/978-94-011-1028-0_18 · Cited by 276
Electrically evoked myoelectric signals.
Merletti, R., Knaflitz, M., & DeLuca, C. J. (1992) · PubMed · Cited by 239
Surface EMG signal processing during isometric contractions
Merletti, R., & Lo Conte, L. R. (1997) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(97)00010-2 · Cited by 227
Wavelet applications in medicine
Akay, M. (1997) · IEEE Spectrum · doi:10.1109/6.590747 · Cited by 196
Self-citationReading and Understanding Continuous Wavelet Transforms
Grossmann, A., Kronland-Martinet, R., & Morlet, J. (1989) · Inverse Problems and Theoretical Imaging · doi:10.1007/978-3-642-97177-8_1 · Cited by 178
Advances in processing of surface myoelectric signals: Part 1
Merletti, R., & Conte, L. L. (1995) · Medical & Biological Engineering & Computing · doi:10.1007/bf02510518 · Cited by 158
Karlsson, S., Yu, J., & Akay, M. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.764944 · Cited by 122
Self-citationTwo applications of wavelet transforms in magnetic resonance imaging
Healy, D. M., & Weaver, J. B. (1992) · IEEE Transactions on Information Theory · doi:10.1109/18.119740 · Cited by 113
EMG assessment of back muscle function during cyclical lifting
Roy, S. H., Bonato, P., & Knaflitz, M. (1998) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(98)00010-8 · Cited by 105
Short Time Fourier Analysis of the Electromyogram: Fast Movements and Constant Contraction
Hannaford, B., & Lehman, S. L. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325697 · Cited by 88
Advances in processing of surface myoelectric signals: Part 2
Conte, L. L., & Merletti, R. (1995) · Medical & Biological Engineering & Computing · doi:10.1007/bf02510519 · Cited by 59
Cited by
The extraction of neural strategies from the surface EMG
Farina, D., Merletti, R., & Enoka, R. M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01070.2003 · Cited by 1,573
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Surface EMG based muscle fatigue evaluation in biomechanics
Cifrek, M., Medved, V., Tonković, S., & Ostojić, S. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2009.01.010 · Cited by 954
Deep Learning for Electromyographic Hand Gesture Signal Classification Using Transfer Learning
Cote-Allard, U., Fall, C. L., Drouin, A., Campeau-Lecours, A., Gosselin, C., Glette, K., Laviolette, F., & Gosselin, B. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2896269 · Cited by 738
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
Metadata
- Authors
- Karlsson, S., Yu, J., & Akay, M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2000
- Volume
- 47
- Issue
- 2
- Pages
- 228-238
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2161490686
- Cited by
- 358
- References
- 26
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.