The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Time-frequency analysis of myoelectric signals during dynamic contractions: a comparative study
Abstract
In this paper, we introduce the nonstationary signal analysis methods to analyze the myoelectric (ME) signals during dynamic contractions by estimating the time-dependent spectral moments. The time-frequency analysis methods including the short-time Fourier transform, the Wigner-Ville distribution, the Choi-Williams distribution, and the continuous wavelet transform were compared for estimation accuracy and precision on synthesized and real ME signals. It is found that the estimates provided by the continuous wavelet transform have better accuracy and precision than those obtained with the other time-frequency analysis methods on simulated data sets. In addition, ME signals from four subjects during three different tests (maximum static voluntary contraction, ramp contraction, and repeated isokinetic contractions) were also examined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Габор, Д. (1946) · Journal of the IEE · Cited by 5,036
Time-frequency distributions-a review
Cohen, L. (1989) · Proceedings of the IEEE · doi:10.1109/5.30749 · Cited by 3,571
(2009) · Encyclopedia of Neuroscience · doi:10.1007/978-3-540-29678-2_6014 · Cited by 2,850
Wavelets and signal processing
Rioul, O., & Vetterli, M. (1991) · IEEE Signal Processing Magazine · doi:10.1109/79.91217 · Cited by 2,786
(1996) · Adapted Wavelet Analysis · doi:10.1201/9781439863619-15 · Cited by 2,703
Linear and quadratic time-frequency signal representations
Hlawatsch, F., & Boudreaux-Bartels, G. F. (1992) · IEEE Signal Processing Magazine · doi:10.1109/79.127284 · Cited by 1,632 · cited 1×
“Here, we will briefly review the different analysis methods used in the paper (see [1] and [ 19 ] for the details).”
MethodImproved time-frequency representation of multicomponent signals using exponential kernels
Choi, H.-I., & Williams, W. J. (1989) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/assp.1989.28057 · Cited by 1,299
Muscles Alive. Their Functions Revealed by Electromyography
(1962) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1962.tb19834.x · Cited by 854
Physiology and Mathematics of Myoelectric Signals
De Luca, C. J. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326534 · Cited by 684 · cited 2×
“[26], De Luca [13] and Basmajian and De Luca [4] for details.”
BackgroundInterpretation of myoelectric power spectra: A model and its applications
Lindstrom, L. H., & Magnusson, R. I. (1977) · Proceedings of the IEEE · doi:10.1109/proc.1977.10544 · Cited by 419
Cited by
The extraction of neural strategies from the surface EMG
Farina, D., Merletti, R., & Enoka, R. M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01070.2003 · Cited by 1,573
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Surface EMG based muscle fatigue evaluation in biomechanics
Cifrek, M., Medved, V., Tonković, S., & Ostojić, S. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2009.01.010 · Cited by 954
Deep Learning for Electromyographic Hand Gesture Signal Classification Using Transfer Learning
Cote-Allard, U., Fall, C. L., Drouin, A., Campeau-Lecours, A., Gosselin, C., Glette, K., Laviolette, F., & Gosselin, B. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2896269 · Cited by 738
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
Can Ethograms Be Automatically Generated Using Body Acceleration Data from Free-Ranging Birds?
Sakamoto, K. Q., Sato, K., Ishizuka, M., Watanuki, Y., Takahashi, A., Daunt, F., & Wanless, S. (2009) · PLoS ONE · doi:10.1371/journal.pone.0005379 · Cited by 436
Comparison of algorithms for estimation of EMG variables during voluntary isometric contractions
Farina, D., & Merletti, R. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00025-0 · Cited by 367
Electromyographic analysis of pedaling: A review
Hug, F., & Dorel, S. (2009) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2007.10.010 · Cited by 358
Electromyographic models to assess muscle fatigue
González-Izal, M., Malanda, A., Gorostiaga, E., & Izquierdo, M. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2012.02.019 · Cited by 310
A Review of Non-Invasive Techniques to Detect and Predict Localised Muscle Fatigue
Al-Mulla, M. R., Sepulveda, F., & Colley, M. (2011) · Sensors · doi:10.3390/s110403545 · Cited by 310
The Usefulness of Mean and Median Frequencies in Electromyography Analysis
Phinyomark, A., Thongpanja, S., Hu, H., Phukpattaranont, P., & Limsakul, C. (2012) · Computational Intelligence in Electromyography Analysis - A Perspective on Current Applications and Future Challenges · doi:10.5772/50639 · Cited by 294
Young, A. J., Hargrove, L. J., & Kuiken, T. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2159216 · Cited by 287
Forced, not voluntary, exercise improves motor function in Parkinson's disease patients
Ridgel, A. L., Vitek, J. L., & Alberts, J. L. (2009) · Neurorehabilitation and neural repair · doi:10.1177/1545968308328726 · Cited by 284
Bonato, P., Roy, S. H., Knaflitz, M., & de Luca, C. J. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930899 · Cited by 284
Motor unit recruitment for dynamic tasks: current understanding and future directions
Hodson-Tole, E. F., & Wakeling, J. M. (2009) · Journal of Comparative Physiology B · doi:10.1007/s00360-008-0289-1 · Cited by 145
Control of prosthetic hands via the peripheral nervous system
Ciancio, A. L., Cordella, F., Barone, R., Romeo, R. A., Bellingegni, A. D., Sacchetti, R., Davalli, A., Di Pino, G., Ranieri, F., Di Lazzaro, V., et al. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00116 · Cited by 131
Metadata
- Authors
- Karlsson, S., Yu, J., & Akay, M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2000
- Volume
- 47
- Issue
- 2
- Pages
- 228-238
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2161490686
- Cited by
- 358
- References
- 26
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.