A high-yield microassembly structure for three-dimensional microelectrode arrays
Abstract
This paper presents a practical microassembly process for three-dimensional (3-D) microelectrode arrays for recording and stimulation in the central nervous system (CNS). Orthogonal lead transfers between the micromachined two-dimensional probes and a cortical surface platform are formed by attaching gold beams on the probes to pads on the platform using wire-free ultrasonic bonding. The low-profile (150 microns) outrigger design of the probes allows the bonding of fully assembled high-density arrays. Micromachined assembly tools allow the formation of a full 3-D probe array within 30 min. Arrays having up to 8 x 16 shanks on 200-micron centers have been realized and used to record cortical single units successfully. Active 3-D probe arrays containing on-chip CMOS signal processing circuitry have also been created using the microassembly approach. In addition, a dynamic insertion technique has been explored to allow the implantation of high-density probe arrays into feline cortex at high-speed and with minimal traumatic injury.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Because these approaches require special equipment or platforms, microneedle structures that are fabricated either by assembling 2D probe combs or etching bulk materials are expensive and time consuming.”
From A flexible three-dimensional electrode mesh: An enabling technology for wireless brain–computer interface prostheses (2016) · cites this paper as [8]
In the citing paper
“Some neural interface devices have been fabricated with high electrode densities; however, their designs have limited the use of these arrays to specific central nervous system structures, such as cortical grey matter (6.25 electrodes/mm 2 [12,13]; >150 electrodes/mm 2 [17,18]) or hippocampal slices (<11 electrodes/mm 2 [19]).”
From A new high-density (25 electrodes/mm2) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures (2013) · cites this paper as [12]
Citations
Cites
A method for the study of undecalcified bones and teeth with attached soft tissues*
Donath, K., & Breuner, G. (1982) · Journal of Oral Pathology and Medicine · doi:10.1111/j.1600-0714.1982.tb00172.x · Cited by 1,640
Gamma (40-100 Hz) oscillation in the hippocampus of the behaving rat
Bragin, A., Jando, G., Nadasdy, Z., Hetke, J., Wise, K., & Buzsaki, G. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-01-00047.1995 · Cited by 1,527
Self-citationCampbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 481
A three-dimensional microelectrode array for chronic neural recording
Hoogerwerf, A. C., & Wise, K. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.335862 · Cited by 372
Self-citationA method for pneumatically inserting an array of penetrating electrodes into cortical tissue
Rousche, P. J., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368133 · Cited by 305
A high-yield IC-compatible multichannel recording array
Najafi, K., Wise, K. D., & Mochizuki, T. (1985) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1985.22102 · Cited by 303
Self-citationSingle-unit neural recording with active microelectrode arrays
Bai, Q., & Wise, K. D. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.936367 · Cited by 214
Self-citationSilicon ribbon cables for chronically implantable microelectrode arrays
Hetke, J. F., Lund, J. L., Najafi, K., Wise, K. D., & Anderson, D. J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284959 · Cited by 174
Self-citationAn implantable CMOS circuit interface for multiplexed microelectrode recording arrays
Ji, J., & Wise, K. D. (1992) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.121568 · Cited by 172
Self-citationLepselter, M. P. (1966) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1966.tb00018.x · Cited by 163
Multiple single-unit recordings from the CNS using thin-film electrode arrays
Carter, R. R., & Houk, J. C. (1993) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.279266 · Cited by 34
A 64-site Multiplexed Low-profile Neural Probe With On-chip Cmos Circuitry
Kim, C., & Wise, K. D. (2005) · doi:10.1109/vlsic.1994.586234 · Cited by 10
Self-citationA High-Yield Process for Three-Dimensional Microelectrode Arrays
Bai, Q., & Kuo, A. D. (1996) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh1996.59 · Cited by 10
Self-citationBielen, J. A., Schmidt, A., Weiel, R., & Rutten, W. L. C. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1996.656947 · Cited by 9
Frieswijk, T. A., & Rutten, W. L. C. (2002) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1994.415155 · Cited by 7
A technique for electrically inserting electrode arrays into peripheral nerves
Smit, J. P. A., & Rutten, W. L. C. (2002) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1994.415150 · Cited by 4
Edwards, C., Finger, P. A., Anderson, D., Wiler, J. A., Hetke, J. F., & Altschuler, R. A. (1997) · Microscopy and Microanalysis · doi:10.1017/s1431927600008643 · Cited by 2
Self-citation
Research works printed but not linked: 1
- lund, 1994, chip-level encapsulation of implantable cmos microelectrode arrays, Tech Dig IEEE Solid-State Sensors and Actuators Workshop, 29
Cited by
Sorted by citations
Microneedles for drug and vaccine delivery
Kim, Y., Park, J., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,776
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Self-citationMaterials for flexible bioelectronic systems as chronic neural interfaces
Song, E., Li, J., Won, S. M., Bai, W., & Rogers, J. A. (2020) · Nature Materials · doi:10.1038/s41563-020-0679-7 · Cited by 498
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 484
Kipke, D. R., Vetter, R. J., Williams, J. C., & Hetke, J. F. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814443 · Cited by 364
Metadata
- Authors
- Bai, Q., Wise, K. D., & Anderson, D. J.
- Affiliations
- University of Michigan (US)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2000-03
- Volume
- 47
- Issue
- 3
- Pages
- 281-289
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2161272185
- Cited by
- 245
- References
- 20
- Citations by year
- 2025: 5 · 2023: 4 · 2022: 8 · 2021: 6 · 2020: 7 · 2019: 5 · 2018: 6 · 2017: 7 · 2016: 14 · 2015: 8 · 2014: 7 · 2013: 11 · 2012: 7
- FWCI
- 2.84
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- microassembly, ultrasonic bonding, cortical recording, single-unit recording, neurostimulation
- MeSH terms
- Animals, Auditory Cortex, Brain, Cats, Electrodes, Implanted, Electroencephalography, Equipment Design, Gold, Guinea Pigs, Microelectrodes, Signal Processing, Computer-Assisted, Silicon, Microscopy, Confocal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review