Noninvasive estimation of motor unit conduction velocity distribution using linear electrode arrays
The DOI matches its Crossref record.
Abstract
Determining the conduction velocity of motor unit action potentials is one of the most important problems in surface electromyography. The estimate of one average conduction velocity value depends on a variety of uncontrollable factors. More meaningful information is obtained from the estimation of the distribution of the different delays in the myoelectric signals. A solution to the problem is the separation and characterization of the individual components propagating at different velocities. A technique, based on surface electrode array recording, is proposed to estimate motor unit conduction velocity distribution. The method consists in the identification of the single action potentials in the time scale domain (with the continuous wavelet transform) and in the estimation of their conduction velocities based on the beamforming algorithm. The performances of the technique have been evaluated using simulated and real myoelectric signals. The results demonstrate that the technique is accurate and reliable. The method may be useful for the diagnosis of neuromuscular disorders, for the monitoring of muscle fatigue and for noninvasive investigation of individual motor units.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Development of recommendations for SEMG sensors and sensor placement procedures
Hermens, H. J., Freriks, B., Disselhorst-Klug, C., & Rau, G. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00027-4 · Cited by 7,213
Analysis of motor units with high-density surface electromyography
Merletti, R., Holobar, A., & Farina, D. (2008) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.09.002 · Cited by 350
Self-citationMerletti, R., Botter, A., Troiano, A., Merlo, E., & Minetto, M. A. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.08.006 · Cited by 345
Self-citationSurface Electromyography for Noninvasive Characterization of Muscle
Merletti, R., Rainoldi, A., & Farina, D. (2001) · Exercise and Sport Sciences Reviews · doi:10.1097/00003677-200101000-00005 · Cited by 325
Self-citationEstimating motor unit discharge patterns from high-density surface electromyogram.
Holobar, A., Farina, D., Gazzoni, M., Merletti, R., & Zazula, D. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.10.160 · Cited by 318
“3 m/s (Farina et al., 2000) and with the smallest MUs assigned the slowest conduction velocities (Andreassen and Arendt-Nielsen, 1987).”
BackgroundMethodInfluentialSelf-citationMotor unit recruitment strategies investigated by surface EMG variables
Farina, D., Fosci, M., & Merletti, R. (2002) · Journal of Applied Physiology · doi:10.1152/jappl.2002.92.1.235 · Cited by 318
Self-citationClinical applications of high-density surface EMG: A systematic review
Drost, G., Stegeman, D. F., van Engelen, B. G. M., & Zwarts, M. J. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.09.005 · Cited by 311
Multichannel surface EMG: Basic aspects and clinical utility
Zwarts, M. J., & Stegeman, D. F. (2003) · Muscle & Nerve · doi:10.1002/mus.10358 · Cited by 302
The linear electrode array: a useful tool with many applications
Merletti, R., Farina, D., & Gazzoni, M. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00082-2 · Cited by 285
Self-citationA fast and reliable technique for muscle activity detection from surface EMG signals
Merlo, A., Farina, D., & Merletti, R. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.808829 · Cited by 284
Self-citationA novel approach for precise simulation of the EMG signal detected by surface electrodes
Farina, D., & Merletti, R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.923782 · Cited by 282
Self-citationEffect of joint angle on EMG variables in leg and thigh muscles
Farina, D., Merletti, R., Nazzaro, M., & Caruso, I. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.982277 · Cited by 197
Self-citationGazzoni, M., Farina, D., & Merletti, R. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.01.002 · Cited by 179
Self-citationA thin, flexible multielectrode grid for high-density surface EMG
Lapatki, B. G., van Dijk, J. P., Jonas, I. E., Zwarts, M. J., & Stegeman, D. F. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00521.2003 · Cited by 172
Gallina, A., Disselhorst-Klug, C., Farina, D., Merletti, R., Besomi, M., Holobar, A., Enoka, R. M., Hug, F., Falla, D., Søgaard, K., et al. (2022) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2022.102656 · Cited by 77
Self-citationAvila, E. R., Williams, S. E., & Disselhorst-Klug, C. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111687 · Cited by 44
Metadata
- Authors
- Farina, D., Fortunato, E., & Merletti, R.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2000-03
- Volume
- 47
- Issue
- 3
- Pages
- 380-388
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2159501664
- Cited by
- 155
- References
- 0
- FWCI
- 8.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.