A novel approach for precise simulation of the EMG signal detected by surface electrodes
Abstract
We propose a new electromyogram generation and detection model. The volume conductor is described as a nonhomogeneous (layered) and anisotropic medium constituted by muscle, fat and skin tissues. The surface potential detected in space domain is obtained from the application of a two-dimensional spatial filter to the input current density source. The effects of electrode configuration, electrode size and inclination of the fibers with respect to the detection system are included in the transfer function of the filter. Computation of the signal in space domain is performed by applying the Radon transform; this permits to draw considerations about spectral dips and clear misunderstandings in previous theoretical derivations. The effects of generation and extinction of the action potentials at the fiber end plate and at the tendons are included by modeling the source current, without any approximation of its shape, as a function of space and time and by using again the Radon transform. The approach, based on the separation of the temporal and spatial properties of the muscle fiber action potential and of the volume conductor, includes the capacitive tissue properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Mathematics of Computerized Tomography
Natterer, F., & Wang, G. (2002) · Medical Physics · doi:10.1118/1.1429631 · Cited by 2,524
The Mathematics of Computerized Tomography
Natterer, F. (1986) · Vieweg+Teubner eBooks · doi:10.1007/978-3-663-01409-6 · Cited by 1,768
Models of recruitment and rate coding organization in motor-unit pools.
Fuglevand, A. J., Winter, D. A., & Patla, A. E. (1993) · Journal of Neurophysiology · doi:10.1152/jn.1993.70.6.2470 · Cited by 988 · cited 1×
“8 and 9 show examples of simulated surface EMG signals detected during electrically elicited and voluntary contractions [13], [29], [41].”
Lindström, L., Magnusson, R., & Petersén, I. (1970) · PubMed · Cited by 553
Interpretation of myoelectric power spectra: A model and its applications
Lindstrom, L. H., & Magnusson, R. I. (1977) · Proceedings of the IEEE · doi:10.1109/proc.1977.10544 · Cited by 419
Rosenfalck, P. (1969) · PubMed · Cited by 373
Comparison of algorithms for estimation of EMG variables during voluntary isometric contractions
Farina, D., & Merletti, R. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00025-0 · Cited by 367
Self-citationFuglevand, A. J., Winter, D. A., Patla, A. E., & Stashuk, D. (1992) · Biological Cybernetics · doi:10.1007/bf00201021 · Cited by 311
The active fiber in a volume conductor
Plonsey, R. (1974) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1974.324406 · Cited by 209
Surface EMG models: properties and applications
Stegeman, D. F., Blok, J. H., Hermens, H. J., & Roeleveld, K. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00023-7 · Cited by 209
Modeling of surface myoelectric signals. I. Model implementation
Merletti, R., Lo Conte, L., Avignone, E., & Guglielminotti, P. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.771190 · Cited by 208
Self-citationDisselhorst-Klug, C., Silny, J., & Rau, G. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.594897 · Cited by 172
Reucher, H., Rau, G., & Silny, J. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326034 · Cited by 166
Noninvasive estimation of motor unit conduction velocity distribution using linear electrode arrays
Farina, D., Fortunato, E., & Merletti, R. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.827303 · Cited by 156
Self-citationInfluence of electrode geometry on bipolar recordings of the surface electromyogram
Lynn, P. A., Bettles, N. D., Hughes, A., & Johnson, S. (1978) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442444 · Cited by 153
Volume conduction models for surface EMG; confrontation with measurements
Roeleveld, K., Blok, J. H., Stegeman, D. F., & van Oosterom, A. (1997) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(97)00009-6 · Cited by 141
Modeling of surface myoelectric signals. II. Model-based signal interpretation
Merletti, R., Roy, S. H., Kupa, E. J., Roatta, S., & Granata, A. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.771191 · Cited by 135
Self-citationReucher, H., Silny, J., & Rau, G. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326035 · Cited by 129
Gootzen, T. H. J. M., Stegeman, D. F., & van Oosterom, A. (1991) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(91)90008-l · Cited by 127
Non-invasive assessment of motor unit properties with linear electrode arrays.
Merletti, R., Farina, D., & Granata, A. (1999) · PubMed · Cited by 118
Self-citationRau, G., & Dißelhorst-Klug, C. (1997) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(97)00007-2 · Cited by 109
Model of the extracellular potential field of a single striated muscle fibre.
Dimitrova, N. A. (1975) · PubMed · Cited by 63
Schneider, J., Silny, J., & Rau, G. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83605 · Cited by 61
Rau, G., Dißelhorst-Klug, C., & Silny, J. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)00169-8 · Cited by 57
Influence of the muscle fibre end geometry on the extracellular potentials
Gydikov, A., Gerilovsky, L., Radicheva, N., et al. (1986) · Biological Cybernetics · doi:10.1007/bf00337110 · Cited by 56
Effect of electrode parameters on the bandwidth of the surface e.m.g. power-density spectrum
Zipp, P. (1978) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457805 · Cited by 56
Simulation of electromyographic signals
Stashuk, D. W. (1993) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(05)80003-3 · Cited by 55
Some observations on the EEG in hepatic coma
Silverman, D. H. S. (1962) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(62)90006-8 · Cited by 51
Dißelhorst-Klug, C., Silny, J., & Rau, G. (1998) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(98)00015-7 · Cited by 44
The spatial integration effect of surface electrode detecting myoelectric signal
Helal, J.-N., & Bouissou, P. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.168695 · Cited by 42
Cited by
The extraction of neural strategies from the surface EMG
Farina, D., Merletti, R., & Enoka, R. M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01070.2003 · Cited by 1,573
Self-citationMultichannel Blind Source Separation Using Convolution Kernel Compensation
Holobar, A., & Zazula, D. (2007) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2007.896108 · Cited by 648
Influence of amplitude cancellation on the simulated surface electromyogram
Keenan, K. G., Farina, D., Maluf, K. S., Merletti, R., & Enoka, R. M. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00894.2004 · Cited by 389
Self-citationDecoding the neural drive to muscles from the surface electromyogram
Farina, D., Holobar, A., Merletti, R., & Enoka, R. M. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.10.040 · Cited by 383
Self-citationInfluence of anatomical, physical, and detection-system parameters on surface EMG
Farina, D., Cescon, C., & Merletti, R. (2002) · Biological Cybernetics · doi:10.1007/s00422-002-0309-2 · Cited by 373
Self-citation
Metadata
- Authors
- Farina, D., & Merletti, R.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2001-06
- Volume
- 48
- Issue
- 6
- Pages
- 637-646
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2107142258
- Cited by
- 282
- References
- 30
- FWCI
- 12.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.