The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Single-unit neural recording with active microelectrode arrays
Abstract
This paper discusses the single-unit recording characteristics of microelectrode arrays containing on-chip signal processing circuitry. Probes buffered using on-chip unity-gain operational amplifiers provide an output resistance of 200 ohm with an input-referred noise of 11-muV root-mean-square (rms) (100 Hz-10 kHz). Simultaneous in vivo recordings from single neurons using buffered and unbuffered (passive) iridium recording sites separated by less than 20 microm have shown that the use of on-chip circuitry does not significantly degrade system noise. Single-unit neural activity has also been studied using probes containing closed-loop preamplifiers having a voltage gain of 40 dB and a bandwidth of 13 kHz, and several input dc-baseline stabilization techniques have been evaluated. Low-noise in vivo recordings with a multiplexed probe have been demonstrated for the first time using an external asymmetrical clock running at 200 kHz. The multiplexed system adds less than 8-muV rms of noise to the recorded signals, suppressing the 5-V clock transitions to less than 2 ppm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gamma (40-100 Hz) oscillation in the hippocampus of the behaving rat
Bragin, A., Jando, G., Nadasdy, Z., Hetke, J., Wise, K., & Buzsaki, G. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-01-00047.1995 · Cited by 1,527
Self-citationCampbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
A high-yield microassembly structure for three-dimensional microelectrode arrays
Bai, Q., Wise, K. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.827288 · Cited by 245
Self-citation
Cited by
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Connecting cortex to machines: recent advances in brain interfaces
Donoghue, J. P. (2002) · Nature Neuroscience · doi:10.1038/nn947 · Cited by 721
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Self-citationMassively Parallel Recording of Unit and Local Field Potentials With Silicon-Based Electrodes
Csicsvari, J., Henze, D. A., Jamieson, B., Harris, K. D., Sirota, A., Barthó, P., Wise, K. D., & Buzsáki, G. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00116.2003 · Cited by 402
Self-citation
Metadata
- Authors
- Bai, Q., & Wise, K. D.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2001
- Volume
- 48
- Issue
- 8
- Pages
- 911-920
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2150634592
- Cited by
- 215
- References
- 3
- FWCI
- 3.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single-unit neural recording with active microelectrode arrays. https://app.cochat.ai/papers/10.1109/10.936367
- The paper
- Bai, Q., & Wise, K. D. (2001). Single-unit neural recording with active microelectrode arrays. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.936367
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.