The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
EEG complexity as a measure of depth of anesthesia for patients
Abstract
A new approach for quantifying the relationship between brain activity patterns and depth of anesthesia (DOA) is presented by analyzing the spatio-temporal patterns in the electroencephalogram (EEG) using Lempel-Ziv complexity analysis. Twenty-seven patients undergoing vascular surgery were studied under general anesthesia with sevoflurane, isoflurane, propofol, or desflurane. The EEG was recorded continuously during the procedure and patients' anesthesia states were assessed according to the responsiveness component of the observer's assessment of alertness/sedation (OAA/S) score. An OAA/S score of zero or one was considered asleep and two or greater was considered awake. Complexity of the EEG was quantitatively estimated by the measure C(n), whose performance in discriminating awake and asleep states was analyzed by statistics for different anesthetic techniques and different patient populations. Compared with other measures, such as approximate entropy, spectral entropy, and median frequency, C(n) not only demonstrates better performance (93% accuracy) across all of the patients, but also is an easier algorithm to implement for real-time use. The study shows that C(n) is a very useful and promising EEG-derived parameter for characterizing the (DOA) under clinical situations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Approximate entropy as a measure of system complexity.
Pincus, S. M. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.6.2297 · Cited by 5,811
Characterization of Strange Attractors
Grassberger, P., & Procaccia, I. (1983) · Physical Review Letters · doi:10.1103/physrevlett.50.346 · Cited by 4,857
On the Complexity of Finite Sequences
Lempel, A., & Ziv, J. (1976) · IEEE Transactions on Information Theory · doi:10.1109/tit.1976.1055501 · Cited by 2,717
Tononi, G. (1998) · Science · doi:10.1126/science.282.5395.1846 · Cited by 1,561
A Primer for EEG Signal Processing in Anesthesia
Rampil, I. J. (1998) · Anesthesiology · doi:10.1097/00000542-199810000-00023 · Cited by 1,503
Validity and Reliability of the Observer??s: Assessment of Alertness/Sedation Scale
CHERNIK, D. A., GILLINGS, D., LAINE, H., HENDLER, J., SILVER, J. M., DAVIDSON, A. B., SCHWAM, E. M., & SIEGEL, J. L. (1990) · Journal of Clinical Psychopharmacology · doi:10.1097/00004714-199008000-00003 · Cited by 1,246
Approximate entropy (ApEn) as a complexity measure
Pincus, S. (1995) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.166092 · Cited by 1,213
Characterization of Strange Attractor
秦, 浩., 堀田, 武., 冨田, 浩., 小林, 達., & Morita, T. (1987) · Kyoto University Research Information Repository (Kyoto University) · Cited by 817
NONLINEAR TIME SEQUENCE ANALYSIS
GRASSBERGER, P., SCHREIBER, T., & SCHAFFRATH, C. (1991) · International Journal of Bifurcation and Chaos · doi:10.1142/s0218127491000403 · Cited by 526
Easily calculable measure for the complexity of spatiotemporal patterns
Kaspar, F., & Schuster, H. G. (1987) · Physical Review A · doi:10.1103/physreva.36.842 · Cited by 505
Use of the fractal dimension for the analysis of electroencephalographic time series
Affinito, M., Carrozzi, M., Accardo, A., & Bouquet, F. (1997) · Biological Cybernetics · doi:10.1007/s004220050394 · Cited by 426
Bruhn, J., Röpcke, H., & Hoeft, A. (2000) · Anesthesiology · doi:10.1097/00000542-200003000-00016 · Cited by 368
Drummond, J. C., & Weiskopf, R. B. (2000) · Anesthesiology · doi:10.1097/00000542-200009000-00039 · Cited by 366
Stochastic complexity measures for physiological signal analysis
Rezek, I. A., & Roberts, S. J. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.709563 · Cited by 288
Estimating regularity in epileptic seizure time-series data
Radhakrishnan, N., & Gangadhar, B. N. (1998) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.677174 · Cited by 196
A complexity measure for selective matching of signals by the brain.
Tononi, G., Sporns, O., & Edelman, G. M. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.8.3422 · Cited by 191
Awareness with Recall During General Anesthesia: Incidence and Risk Factors
Ranta, S. O.-V., Laurila, R., Saario, J., Ali-Melkkila, T., & Hynynen, M. (1998) · Anesthesia & Analgesia · doi:10.1097/00000539-199805000-00035 · Cited by 182
EEG complexity and performance measures of creative thinking
Mölle, M., Marshall, L., Wolf, B., Fehm, H. L., & Born, J. (1999) · Psychophysiology · doi:10.1017/s0048577299961619 · Cited by 161
SLEIGH, J. W., & Donovan, J. K. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/82.5.666 · Cited by 152
Bispectrum Analysis of Electroencephalogram Signals during Waking and Sleeping
Barnett, T. P., Johnson, L. C., Naitoh, P., et al. (1971) · Science · doi:10.1126/science.172.3981.401 · Cited by 140
The Design and Analysis of Pattern Recognition Experiments
Highleyman, W. H. (1962) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1962.tb02426.x · Cited by 134
The evolution of complexity in human brain development: an EEG study
Meyer-Lindenberg, A. (1996) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95699-0 · Cited by 125
Information transmission in human cerebral cortex
Xu, J., Liu, Z., Liu, R., & Yang, Q.-F. (1997) · Physica D Nonlinear Phenomena · doi:10.1016/s0167-2789(97)00042-0 · Cited by 112
Non-linear dynamic complexity of the human EEG during evoked emotions
Aftanas, L. I., Lotova, N. V., Koshkarov, V. I., Makhnev, V. P., Mordvintsev, Y. N., & Popov, S. A. (1998) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(97)00067-6 · Cited by 89
Quantification of depth of anesthesia by nonlinear time series analysis of brain electrical activity
Widman, G., Schreiber, T., Rehberg, B., Hoeft, A., & Elger, C. E. (2000) · Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics · doi:10.1103/physreve.62.4898 · Cited by 83
Complexity of electrocortical dynamics in children: Developmental aspects
Anokhin, A. P., Lutzenberger, W., Nikolaev, A. R., & Birbaumer, N. (2000) · Developmental Psychobiology · doi:10.1002/(sici)1098-2302(200001)36:1<9::aid-dev2>3.0.co;2-5 · Cited by 68
Awareness with Recall During General Anesthesia
Ranta, S. O.-V., & Hynynen, M. J. (1998) · Anesthesia & Analgesia · doi:10.1097/00000539-199812000-00066 · Cited by 66
Fractal dimensions of short EEG time series in humans
Preissl, H. T., Lutzenberger, W., Friedemann Pulvermüller, A., & Birbaumer, N. (1997) · Neuroscience Letters · doi:10.1016/s0304-3940(97)00192-4 · Cited by 62
Detection of seizures from small samples using nonlinear dynamic system theory
Yaylali, I., Koçak, H., & Jayakar, P. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.503182 · Cited by 57
Zhang, X. S., Zhu, Y. S., & Zhang, X. J. (1997) · Medical & Biological Engineering & Computing · doi:10.1007/bf02525525 · Cited by 43
Self-citationDesign of a recognition system to predict movement during anesthesia
Sharma, A., & Roy, R. J. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.581946 · Cited by 39
Self-citationQuantitative measure of complexity of EEG signal dynamics
Włodzimierz, Jernajczyk, W., Niedzielska, K., Rydz, A., & Stepien, R. (1999) · Acta Neurobiologiae Experimentalis · doi:10.55782/ane-1999-1316 · Cited by 36
Estimating complexity from EEG background activity of epileptic patients
Hornero, R., Espino, P., Alonso, A., & López, M. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.805149 · Cited by 34
Tirsch, W. S., Keidel, M., Perz, S. G., et al. (2000) · Biological Cybernetics · doi:10.1007/pl00007957 · Cited by 24
Cited by
The entropic brain - revisited
Carhart-Harris, R. L. (2018) · Neuropharmacology · doi:10.1016/j.neuropharm.2018.03.010 · Cited by 522
Joint Classification and Prediction CNN Framework for Automatic Sleep Stage Classification
Phan, H., Andreotti, F., Cooray, N., Chen, O. Y., & De Vos, M. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2872652 · Cited by 464
Approximate Entropy as a diagnostic tool for machine health monitoring
Yan, R., & Gao, R. X. (2007) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2006.02.009 · Cited by 454
Depression biomarkers using non-invasive EEG: A review
de Aguiar Neto, F. S., & Rosa, J. L. G. (2019) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2019.07.021 · Cited by 451
Increased spontaneous MEG signal diversity for psychoactive doses of ketamine, LSD and psilocybin
Schartner, M. M., Carhart-Harris, R. L., Barrett, A. B., Seth, A. K., & Muthukumaraswamy, S. D. (2017) · Scientific Reports · doi:10.1038/srep46421 · Cited by 410
Metadata
- Authors
- Zhang, X.-S., Roy, R. J., & Jensen, E. W.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2001
- Volume
- 48
- Issue
- 12
- Pages
- 1424-1433
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2137478377
- Cited by
- 495
- References
- 34
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.