A multiple-layer finite-element model of the surface EMG signal
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The effect of skin, muscle, fat, and bone tissue on simulated surface electromyographic (EMG) signals was examined using a finite-element model. The amplitude and frequency content of the surface potential were observed to increase when the outer layer of a homogeneous muscle model was replaced with highly resistive skin or fat tissue. The rate at which the surface potential decreased as the fiber was moved deeper within the muscle also increased. Similarly, the rate at which the surface potential decayed around the surface of the model, for a constant fiber depth, increased. When layers of subcutaneous fat of increasing thickness were then added to the model, EMG amplitude, frequency content, and the rate of decay of the surface EMG signal around the limb decreased, due to the increased distance between the electrodes and the active fiber. The influence of bone on the surface potential was observed to vary considerably, depending on its location. When located close to the surface of the volume conductor, the surface EMG signal between the bone and the source and directly over the bone increased, accompanied by a slight decrease on the side of the bone distal to the active fiber. The results emphasize the importance of distinguishing between the effects of material properties and the distance between source and electrode when considering the influence of subcutaneous tissue, and suggest possible distortions in the surface EMG signal in regions where a bone is located close to the skin surface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175
Cited by
Kuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
Self-citationA Comparison of Surface and Intramuscular Myoelectric Signal Classification
Hargrove, L. J., Englehart, K., & Hudgins, B. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889192 · Cited by 518
Tutorial. Surface EMG detection in space and time: Best practices
Merletti, R., & Muceli, S. (2019) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2019.102363 · Cited by 290
Targeted Muscle Reinnervation and Advanced Prosthetic Arms
Cheesborough, J., Smith, L., Kuiken, T., & Dumanian, G. (2015) · Seminars in Plastic Surgery · doi:10.1055/s-0035-1544166 · Cited by 206
Self-citationFeature extraction of forearm EMG signals for prosthetics
Rafiee, J., Rafiee, M. A., Yavari, F., & Schoen, M. P. (2011) · Expert Systems with Applications · doi:10.1016/j.eswa.2010.09.068 · Cited by 165
Targeted Muscle Reinnervation for the Upper and Lower Extremity
Kuiken, T. A., Barlow, A. K., Hargrove, L. J., & Dumanian, G. A. (2017) · Techniques in Orthopaedics · doi:10.1097/bto.0000000000000194 · Cited by 143
Self-citationOptimizing NV magnetometry for magnetoneurography and magnetomyography applications
Zhang, C., Zhang, J., Widmann, M., Benke, M., Kübler, M., Dasari, D., Klotz, T., Gizzi, L., Röhrle, O., Brenner, P., et al. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.1034391 · Cited by 34
Metadata
- Authors
- Lowery, M. M., Stoykov, N. S., Taflove, A., & Kuiken, T. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2002-05
- Volume
- 49
- Issue
- 5
- Pages
- 446-454
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2100383826
- Cited by
- 152
- References
- 1
- FWCI
- 7.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.