Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 183

The DOI matches its Crossref record.

Design studies for a PET detector module using a PIN photodiode to measure depth of interaction

Open access
Moses, W.W., Derenzo, S.E. · 1994 · IEEE Transactions on Nuclear Science

Abstract

We present design studies of a multi-layer PET detector module that uses an 8/spl times/8 array of 3 mm square PIN photodiodes to both identify the crystal of interaction and measure the depth of interaction. Each photodiode is coupled to one end of a 3/spl times/3/spl times/30 mm BGO crystal, with the opposite ends of 64 such crystals attached to a single 1" square photomultiplier tube that provides a timing signal and energy discrimination. Each BGO crystal is coated with a lossy reflector, so the ratio of light detected in the photodiode and photomultiplier tube depends on the interaction depth in the crystal, and is used to determine this depth of interaction on an event by event basis, A test module with one 3/spl times/3/spl times/30 mm BGO crystal, one 3 mm square PIN photodiode, and one photomultiplier tube is operated at -20/spl deg/C with an amplifier peaking time of 4 /spl mu/s, and a depth of interaction resolution of 5 to 8 mm fwhm measured. Simulations predict that this virtually eliminates radial elongation in a 60 cm diameter BGO tomograph. The photodiode signal corresponding to 511 keV energy deposit varies linearly with excitation position, ranging from 1250 electrons (e/sup -/) at the end closest to the photodiode to 520 e/sup -/ at the opposite end. The electronic noise is a position independent 330 e/sup -/ fwhm, so the signal to noise ratio is sufficient to reliably identify the crystal of interaction in a 64 element module.>

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/23.322929

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Moses, W. W., & Derenzo, S. E.
Venue
IEEE Transactions on Nuclear Science
Published
1994-08
Volume
41
Issue
4
Pages
1441-1445
ISSN
  • 0018-9499 (ISSN-L)
  • 1558-1578
OpenAlex
W2107675308
Cited by
183
References
0
FWCI
9.00
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Design studies for a PET detector module using a PIN photodiode to measure depth of interaction. https://app.cochat.ai/papers/10.1109/23.322929
The paper
Moses, W. W., & Derenzo, S. E. (1994). Design studies for a PET detector module using a PIN photodiode to measure depth of interaction. IEEE Transactions on Nuclear Science. https://doi.org/10.1109/23.322929

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.