The DOI matches its Crossref record.
Investigation of fault modes of voltage-fed inverter system for induction motor drive
Abstract
The reliability of power electronics systems is of paramount importance in industrial, commercial, aerospace, and military applications. The knowledge about the fault mode behavior of a converter system is extremely important from the standpoint of improved system design, protection, and fault tolerant control. This paper describes a systematic investigation into the various fault modes of a voltage-fed PWM inverter system for induction motor drives. After identifying all the fault modes, a preliminary mathematical analysis has been made for the key fault types, namely, input supply single line to ground fault, rectifier diode short circuit, inverter transistor base drive open, and inverter transistor short-circuit conditions. The predicted fault performances are then substantiated by simulation study. The study has been used to determine stresses in power circuit components and to evaluate satisfactory post-fault steady-state operating regions. The results are equally useful for better protection system design and easy fault diagnosis. They will be used to improve system reliability by using fault tolerant control.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Survey of fault-tolerance techniques for three-phase voltage source inverters
Mirafzal, B. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301712 · Cited by 440
Experimental fault-tolerant control of a PMSM drive
Bolognani, S., Zordan, M., & Zigliotto, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873223 · Cited by 382
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629048 · Cited by 304
Fault Diagnosis and Reconfiguration for Multilevel Inverter Drive Using AI-Based Techniques
Khomfoi, S., & Tolbert, L. M. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.906994 · Cited by 284
Metadata
- Authors
- Kastha, D., & Bose, B. K.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 1994
- Volume
- 30
- Issue
- 4
- Pages
- 1028-1038
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W4240840756
- Cited by
- 386
- References
- 0
- FWCI
- 1.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Investigation of fault modes of voltage-fed inverter system for induction motor drive. https://app.cochat.ai/papers/10.1109/28.297920
- The paper
- Kastha, D., & Bose, B. K. (1994). Investigation of fault modes of voltage-fed inverter system for induction motor drive. IEEE Transactions on Industry Applications. https://doi.org/10.1109/28.297920
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.