The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Fault detection and isolation on a PWM inverter by knowledge-based model
Abstract
This paper presents an approach based on knowledge models to detect and localize faults in a PWM inverter supplying a synchronous machine. These faults don't affect the system protection. A diagnostic system which uses only the input variables of the drive is presented. It is based on the analysis of the current vector trajectory and of the instantaneous frequency in faulty mode. These two methods have been successfully applied to an experimental system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fault diagnosis in dynamic systems using analytical and knowledge-based redundancy
Frank, P. M. (1990) · Automatica · doi:10.1016/0005-1098(90)90018-d · Cited by 3,545
Fault Tree Analysis, Methods, and Applications ߝ A Review
Lee, W. S., Grosh, D. L., Tillman, F. A., & Lie, C. H. (1985) · IEEE Transactions on Reliability · doi:10.1109/tr.1985.5222114 · Cited by 678
Fault diagnosis of machines via parameter estimation and knowledge processing—Tutorial paper
Isermann, R. (1993) · Automatica · doi:10.1016/0005-1098(93)90088-b · Cited by 598
Investigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (1994) · IEEE Transactions on Industry Applications · doi:10.1109/28.297920 · Cited by 386
Investigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (2003) · Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1992.244307 · Cited by 370
FAULT DIAGNOSIS OF MACHINES VIA PARAMETER ESTIMATION AND KNOWLEDGE PROCESSING
Isermann, R. (1992) · Elsevier eBooks · doi:10.1016/b978-0-08-041275-7.50010-7 · Cited by 168
Cited by
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377
Fault-Tolerant Voltage Source Inverter for Permanent Magnet Drives
Errabelli, R. R., & Mutschler, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2135866 · Cited by 278
Fuchs, F. W. (2004) · IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468) · doi:10.1109/iecon.2003.1280259 · Cited by 270
Fault-tolerant control in variable speed drives: a survey
Campos-Delgado, D. U., Espinoza-Trejo, D. R., & Palacios, E. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070203 · Cited by 228
Metadata
- Authors
- Peuget, R., Courtine, S., & Rognon, J. P.
- Venue
- IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting
- Publisher
- IEEE
- Published
- 2002-11-22
- Volume
- 2
- Pages
- 1471-1478
- ISSN
- 0197-2618 (ISSN-L)
- OpenAlex
- W2145830182
- Cited by
- 304
- References
- 6
- FWCI
- 12.22
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fault detection and isolation on a PWM inverter by knowledge-based model. https://app.cochat.ai/papers/10.1109/ias.1997.629048
- The paper
- Peuget, R., Courtine, S., & Rognon, J. P. (2002). Fault detection and isolation on a PWM inverter by knowledge-based model. IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting. https://doi.org/10.1109/ias.1997.629048
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.