The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A new control strategy for voltage-type PWM rectifiers to realize zero steady-state control error in input current
Abstract
In this paper, a new simple control strategy for AC input current of voltage-type pulsewidth modulation (PWM) rectifiers which can eliminate the steady-state control error completely is proposed. This control method requires neither the instantaneous value of the supply voltage nor any accurate circuit parameters on the AC side of the rectifier. Thus, a robust operation against the variation of the circuit parameters can be achieved. In the proposed control system, a digital resonant element implemented by a digital signal processor (DSP) is introduced as a feedback controller. The digital resonant element exhibits a function similar to an integrator for the fundamental frequency components. Thus, it can eliminate the steady-state control error of the input current completely, The principle of the proposed control method is discussed, and its effectiveness is shown theoretically. The detailed method of the implementation of the lossless digital resonant element is explained. The effects of the harmonics in the supply voltage on the AC input current waveform are clarified. To confirm the effectiveness of the proposed control method, some experimental results from two laboratory test systems are shown.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hysteresis current-forced three-phase voltage-sourced reversible rectifier
Green, A. W., & Boys, J. T. (1989) · IEE Proceedings B Electric Power Applications · doi:10.1049/ip-b.1989.0016 · Cited by 77
A new state feedback based transient control of PWM AC to DC voltage type converters
Draou, A., Sato, Y., & Kataoka, T. (1995) · IEEE Transactions on Power Electronics · doi:10.1109/63.471291 · Cited by 73
Self-citationA multiple PWM GTO line-side converter for unity power factor and reduced harmonics
Sukegawa, T., Kamiyama, K., Takahashi, J., Ikimi, T., & Matsutake, M. (2002) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.1991.178167 · Cited by 20
Cited by
A Review of Three-Phase Improved Power Quality AC–DC Converters
Singh, B., Singh, B. N., Chandra, A., Al-Haddad, K., Pandey, A., & Kothari, D. P. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825341 · Cited by 1,728
Stationary frame current regulation of PWM inverters with zero steady-state error
Zmood, D. N., & Holmes, D. G. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810852 · Cited by 1,518
Evaluation of Current Controllers for Distributed Power Generation Systems
Timbus, A., Liserre, M., Teodorescu, R., Rodriguez, P., & Blaabjerg, F. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2012527 · Cited by 934
Yuan, X., Allmeling, J., Merk, W., & Stemmler, H. (2002) · Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129) · doi:10.1109/ias.2000.883122 · Cited by 663
Kadri, R., Gaubert, J.-P., & Champenois, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2044733 · Cited by 536
Leon, J. I., Vazquez, S., & Franquelo, L. G. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2726583 · Cited by 481
Metadata
- Authors
- Sato, Y., Ishizuka, T., Nezu, K., & Kataoka, T.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 1998
- Volume
- 34
- Issue
- 3
- Pages
- 480-486
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W4235248977
- Cited by
- 265
- References
- 3
- FWCI
- 0.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.