The DOI matches its Crossref record.
A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities
Abstract
A technique for producing geometrically accurate magnetic resonance images (MRIs) with undistorted intensity in the face of high levels of static field inhomogeneity arising from either source is presented. The technique requires the acquisition of two images of the same object with altered gradients. On the basis of a knowledge of these gradients it employs an automatic postprocessing step that exploits some invariant characteristics of the distortions to produce a rectified image from the two acquired images. No phantom imaging is involved and no operator interaction is required. The technique is theoretically justified and compared to other techniques, and experimental results that show that the technique works are presented. The improved accuracy in geometry and intensity may improve reliability of stereotactic surgery, may enhance the feasibility of both clinical and industrial imaging via external fields, and may increase the resolution of microscopic imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Andersson, J. L. R., Skare, S., & Ashburner, J. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00336-7 · Cited by 3,469
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Twenty‐five pitfalls in the analysis of diffusion MRI data
Jones, D. K., & Cercignani, M. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1543 · Cited by 827
Statistical approach to segmentation of single-channel cerebral MR images
Rajapakse, J. C., Giedd, J. N., & Rapoport, J. L. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563663 · Cited by 678
Registration of head volume images using implantable fiducial markers
Maurer, C. R., Fitzpatrick, J. M., Wang, M. Y., Galloway, R. L., Maciunas, R. J., & Allen, G. S. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.611354 · Cited by 561
Self-citation
Metadata
- Authors
- Chang, H., & Fitzpatrick, J. M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1992
- Volume
- 11
- Issue
- 3
- Pages
- 319-329
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2139609601
- Cited by
- 425
- References
- 0
- FWCI
- 6.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities. https://app.cochat.ai/papers/10.1109/42.158935
- The paper
- Chang, H., & Fitzpatrick, J. M. (1992). A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.158935
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.