Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 425

The DOI matches its Crossref record.

A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities

Chang, H., Fitzpatrick, J.M.·1992·IEEE Transactions on Medical Imaging

Abstract

A technique for producing geometrically accurate magnetic resonance images (MRIs) with undistorted intensity in the face of high levels of static field inhomogeneity arising from either source is presented. The technique requires the acquisition of two images of the same object with altered gradients. On the basis of a knowledge of these gradients it employs an automatic postprocessing step that exploits some invariant characteristics of the distortions to produce a rectified image from the two acquired images. No phantom imaging is involved and no operator interaction is required. The technique is theoretically justified and compared to other techniques, and experimental results that show that the technique works are presented. The improved accuracy in geometry and intensity may improve reliability of stereotactic surgery, may enhance the feasibility of both clinical and industrial imaging via external fields, and may increase the resolution of microscopic imaging.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/42.158935

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 425

Metadata

Authors
Chang, H., & Fitzpatrick, J. M.
Venue
IEEE Transactions on Medical Imaging
Published
1992
Volume
11
Issue
3
Pages
319-329
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2139609601
Cited by
425
References
0
FWCI
6.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities. https://app.cochat.ai/papers/10.1109/42.158935
The paper
Chang, H., & Fitzpatrick, J. M. (1992). A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.158935

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.