The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Automatic detection of brain contours in MRI data sets
Abstract
A software procedure is presented for fully automated detection of brain contours from single-echo 3-D MRI data, developed initially for scans with coronal orientation. The procedure detects structures in a head data volume in a hierarchical fashion. Automatic detection starts with a histogram-based thresholding step, whenever necessary preceded by an image intensity correction procedure. This step is followed by a morphological procedure which refines the binary threshold mask images. Anatomical knowledge, essential for the discrimination between desired and undesired structures, is implemented in this step through a sequence of conventional and novel morphological operations, using 2-D and 3-D operations. A final step of the procedure performs overlap tests on candidate brain regions of interest in neighboring slice images to propagate coherent 2-D brain masks through the third dimension. Results are presented for test runs of the procedure on 23 coronal whole-brain data sets, and one sagittal whole-brain data set. Finally, the potential of the technique for generalization to other problems is discussed, as well as limitations of the technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
Probability, Random Variables, and Stochastic Processes.
Abrahams, J., & Papoulis, A. (1984) · Journal of the American Statistical Association · doi:10.2307/2288754 · Cited by 16,226
Image analysis and mathematical morphology
(1982) · Computer Graphics and Image Processing · doi:10.1016/0146-664x(82)90078-8 · Cited by 8,151
(1982) · Elsevier eBooks · doi:10.1016/c2009-0-21955-6 · Cited by 4,596
Image Analysis Using Mathematical Morphology
Haralick, R. M., Sternberg, S. R., & Zhuang, X. (1987) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1987.4767941 · Cited by 2,710
A survey of thresholding techniques
Sahoo, P. K., Soltani, S., & Wong, A. K. C. (1988) · Computer Vision, Graphics, and Image Processing · doi:10.1016/0734-189x(88)90022-9 · Cited by 2,662
Distance transformations in digital images
Borgefors, G. (1986) · Computer Vision, Graphics, and Image Processing · doi:10.1016/s0734-189x(86)80047-0 · Cited by 1,898
Sequential Operations in Digital Picture Processing
Rosenfeld, A., & Pfaltz, J. L. (1966) · Journal of the ACM · doi:10.1145/321356.321357 · Cited by 1,675
Drebin, R. A., Carpenter, L., & Hanrahan, P. (1988) · ACM SIGGRAPH Computer Graphics · doi:10.1145/378456.378484 · Cited by 1,612
Digital topology: Introduction and survey
Kong, T. Y., & Rosenfeld, A. (1989) · Computer Vision, Graphics, and Image Processing · doi:10.1016/0734-189x(89)90147-3 · Cited by 1,010
Partial volume tissue classification of multichannel magnetic resonance images-a mixel model
Choi, H. S., Haynor, D. R., & Kim, Y. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97590 · Cited by 282
3-D segmentation of MR images of the head for 3-D display
Bomans, M., Hohne, K.-H., Tiede, U., & Riemer, M. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.56342 · Cited by 281
Anatomic segmentation and volumetric calculations in nuclear magnetic resonance imaging
Kennedy, D. N., Filipek, P. A., & Caviness, V. S. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.20356 · Cited by 270
A multiresolution hierarchical approach to image segmentation based on intensity extrema
Lifshitz, L. M., & Pizer, S. M. (1990) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.56189 · Cited by 223
Eigenimage Filtering in MR Imaging
Windham, J. P., Abdallah, M. A., Reimann, D. A., et al. (1988) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198801000-00001 · Cited by 126
Surface of the brain: three-dimensional MR images created with volume rendering.
Levin, D. N., Hu, X. P., Tan, K. K., & Galhotra, S. (1989) · Radiology · doi:10.1148/radiology.171.1.2928539 · Cited by 101
Sexual Dimorphism, Brain Morphology, and Schizophrenia
Lewine, R. R. J., Gulley, L. R., Risch, S. C., Jewart, R. D., & Houpt, J. L. (1990) · Schizophrenia Bulletin · doi:10.1093/schbul/16.2.195 · Cited by 76
Self-citationTissue boundary refinement in magnetic resonance images using contour-based scale space matching
Raman, S. V., Sarkar, S., & Boyer, K. L. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.79468 · Cited by 26
Cited by
Fast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496
The rician distribution of noisy mri data
Gudbjartsson, H., & Patz, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340618 · Cited by 2,494
Morphometric analysis of white matter lesions in MR images: method and validation
Zijdenbos, A. P., Dawant, B. M., Margolin, R. A., & Palmer, A. C. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363096 · Cited by 1,265
Magnetic Resonance Image Tissue Classification Using a Partial Volume Model
Shattuck, D. W., Sandor-Leahy, S. R., Schaper, K. A., Rottenberg, D. A., & Leahy, R. M. (2001) · NeuroImage · doi:10.1006/nimg.2000.0730 · Cited by 950
Automatic "pipeline" analysis of 3-D MRI data for clinical trials: application to multiple sclerosis
Zijdenbos, A. P., Forghani, R., & Evans, A. C. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.806283 · Cited by 761
Metadata
- Authors
- Brummer, M. E., Mersereau, R. M., Eisner, R. L., & Lewine, R. R. J.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1993-06
- Volume
- 12
- Issue
- 2
- Pages
- 153-166
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2132499268
- Cited by
- 297
- References
- 18
- FWCI
- 16.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.