The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Correction of intensity variations in MR images for computer-aided tissue classification
Abstract
A number of supervised and unsupervised pattern recognition techniques have been proposed in recent years for the segmentation and the quantitative analysis of MR images. However, the efficacy of these techniques is affected by acquisition artifacts such as inter-slice, intra-slice, and inter-patient intensity variations. Here a new approach to the correction of intra-slice intensity variations is presented. Results demonstrate that the correction process enhances the performance of backpropagation neural network classifiers designed for the segmentation of the images. Two slightly different versions of the method are presented. The first version fits an intensity correction surface directly to reference points selected by the user in the images. The second version fits the surface to reference points obtained by an intermediate classification operation. Qualitative and quantitative evaluation of both methods reveals that the first one leads to a better correction of the images than the second but that it is more sensitive to operator errors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Learning representations by back-propagating errors
Rumelhart, D. E., Hinton, G. E., & Williams, R. J. (1986) · Nature · doi:10.1038/323533a0 · Cited by 31,892
Multiquadric equations of topography and other irregular surfaces
Hardy, R. L. (1971) · Journal of Geophysical Research · doi:10.1029/jb076i008p01905 · Cited by 2,358
Scattered data interpolation: tests of some methods
Franke, R. (1982) · Mathematics of Computation · doi:10.1090/s0025-5718-1982-0637296-4 · Cited by 1,895
Numerical recipes: The art of scientific computing
DAVIDROPER, L. (1987) · Bulletin of Mathematical Biology · doi:10.1016/s0092-8240(87)90019-x · Cited by 1,424
Nonlinear anisotropic filtering of MRI data
Gerig, G., Kubler, O., Kikinis, R., & Jolesz, F. A. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.141646 · Cited by 1,149
Interpolation using surface splines.
HARDER, R. L., & DESMARAIS, R. N. (1972) · Journal of Aircraft · doi:10.2514/3.44330 · Cited by 770
Hall, L. O., Bensaid, A. M., Clarke, L. P., Velthuizen, R. P., Silbiger, M. S., & Bezdek, J. C. (1992) · IEEE Transactions on Neural Networks · doi:10.1109/72.159057 · Cited by 580
Interpolation des fonctions de deux variables suivant le principe de la flexion des plaques minces
Duchon, J. (1976) · Revue française d'automatique, informatique, recherche opérationnelle. Analyse numérique · doi:10.1051/m2an/197610r300051 · Cited by 484
Scattered Data Interpolation: Tests of Some Method
Franke, R. (1982) · Mathematics of Computation · doi:10.2307/2007474 · Cited by 443
Multivariate interpolation at arbitrary points made simple
Meinguet, J. (1979) · Zeitschrift für angewandte Mathematik und Physik ZAMP · doi:10.1007/bf01601941 · Cited by 413
Cited by
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
“This model has been widely used [14]–[16], [18] and is consistent with the multiplicative nonuniformity arising from variations in the sensitivity of the reception coil and to a lesser extent with the nonuniformity due to induced currents and nonuniform excitation.”
MethodSelf-citationCurrent Methods in Medical Image Segmentation
Pham, D. L., Xu, C., & Prince, J. L. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.315 · Cited by 2,341
A modified fuzzy c-means algorithm for bias field estimation and segmentation of MRI data
Ahmed, M. N., Yamany, S. M., Mohamed, N., Farag, A. A., & Moriarty, T. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.996338 · Cited by 1,792
Adaptive segmentation of MRI data
Wells, W. M., Grimson, W. E. L., Kikinis, R., & Jolesz, F. A. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.511747 · Cited by 1,277
Morphometric analysis of white matter lesions in MR images: method and validation
Zijdenbos, A. P., Dawant, B. M., Margolin, R. A., & Palmer, A. C. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363096 · Cited by 1,265
Self-citationAutomated model-based tissue classification of MR images of the brain
Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811270 · Cited by 1,024
Magnetic Resonance Image Tissue Classification Using a Partial Volume Model
Shattuck, D. W., Sandor-Leahy, S. R., Schaper, K. A., Rottenberg, D. A., & Leahy, R. M. (2001) · NeuroImage · doi:10.1006/nimg.2000.0730 · Cited by 950
A Review of Methods for Correction of Intensity Inhomogeneity in MRI
Vovk, U., Pernus, F., & Likar, B. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.891486 · Cited by 851
Adaptive fuzzy segmentation of magnetic resonance images
Pham, D. L., & Prince, J. L. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.802752 · Cited by 805
Automatic "pipeline" analysis of 3-D MRI data for clinical trials: application to multiple sclerosis
Zijdenbos, A. P., Forghani, R., & Evans, A. C. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.806283 · Cited by 761
Self-citationMRI simulation-based evaluation of image-processing and classification methods
Kwan, R. K.-S., Evans, A. C., & Pike, G. B. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.816072 · Cited by 709
MRI segmentation: Methods and applications
Clarke, L. P., Velthuizen, R. P., Camacho, M. A., Heine, J. J., Vaidyanathan, M., Hall, L. O., Thatcher, R. W., & Silbiger, M. L. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)00124-l · Cited by 695
Statistical approach to segmentation of single-channel cerebral MR images
Rajapakse, J. C., Giedd, J. N., & Rapoport, J. L. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563663 · Cited by 678
Automated model-based bias field correction of MR images of the brain
Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811268 · Cited by 583
Symmetric Atlasing and Model Based Segmentation: An Application to the Hippocampus in Older Adults
Grabner, G., Janke, A. L., Budge, M. M., Smith, D., Pruessner, J., & Collins, D. L. (2006) · Lecture Notes in Computer Science · doi:10.1007/11866763_8 · Cited by 549
A novel kernelized fuzzy C-means algorithm with application in medical image segmentation
Zhang, D.-Q., & Chen, S.-C. (2004) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2004.01.012 · Cited by 544
Parametric estimate of intensity inhomogeneities applied to MRI
Styner, M., Brechbuhler, C., Szckely, G., & Gerig, G. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845174 · Cited by 527
Pham, D. L., & Prince, J. L. (1999) · Pattern Recognition Letters · doi:10.1016/s0167-8655(98)00121-4 · Cited by 472
Li, C., Gore, J. C., & Davatzikos, C. (2014) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.03.010 · Cited by 371
Estimating the bias field of MR images
Guillemaud, R., & Brady, M. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.585758 · Cited by 329
Detection and Mapping of Abnormal Brain Structure with a Probabilistic Atlas of Cortical Surfaces
Thompson, P. M., MacDonald, D., Mega, M. S., Holmes, C. J., Evans, A. C., & Toga, A. W. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00008 · Cited by 322
An adaptive spatial fuzzy clustering algorithm for 3-D MR image segmentation
Liew, A. W.-C., & Yan, H. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.816956 · Cited by 316
An Image-Processing System for Qualitative and Quantitative Volumetric Analysis of Brain Images
Goldszal, A. F., Davatzikos, C., Pham, D. L., Yan, M. X. H., Bryan, R. N., & Resnick, S. M. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199809000-00030 · Cited by 295
Reddick, W. E., Glass, J. O., Cook, E. N., Elkin, T. D., & Deaton, R. J. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.650887 · Cited by 290
Retrospective correction of MR intensity inhomogeneity by information minimization
Likar, B., Viergever, M. A., & Pernus, F. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974934 · Cited by 267
Segmentation of multiple sclerosis lesions in intensity corrected multispectral MRI
Johnston, B., Atkins, M. S., Mackiewich, B., & Anderson, M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.491417 · Cited by 260
A review of Methods for Bias Correction in Medical Images
Song, S., Zheng, Y., & He, Y. (2017) · Biomedical Engineering Review · doi:10.18103/bme.v3i1.1550 · Cited by 62
Metadata
- Authors
- Dawant, B. M., Zijdenbos, A. P., & Margolin, R. A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1993
- Volume
- 12
- Issue
- 4
- Pages
- 770-781
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2115772934
- Cited by
- 291
- References
- 20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.