The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Correction of intensity variations in MR images for computer-aided tissue classification
Abstract
A number of supervised and unsupervised pattern recognition techniques have been proposed in recent years for the segmentation and the quantitative analysis of MR images. However, the efficacy of these techniques is affected by acquisition artifacts such as inter-slice, intra-slice, and inter-patient intensity variations. Here a new approach to the correction of intra-slice intensity variations is presented. Results demonstrate that the correction process enhances the performance of backpropagation neural network classifiers designed for the segmentation of the images. Two slightly different versions of the method are presented. The first version fits an intensity correction surface directly to reference points selected by the user in the images. The second version fits the surface to reference points obtained by an intermediate classification operation. Qualitative and quantitative evaluation of both methods reveals that the first one leads to a better correction of the images than the second but that it is more sensitive to operator errors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Learning representations by back-propagating errors
Rumelhart, D. E., Hinton, G. E., & Williams, R. J. (1986) · Nature · doi:10.1038/323533a0 · Cited by 31,892
Multiquadric equations of topography and other irregular surfaces
Hardy, R. L. (1971) · Journal of Geophysical Research Atmospheres · doi:10.1029/jb076i008p01905 · Cited by 2,811
Scattered data interpolation: tests of some methods
Franke, R. (1982) · Mathematics of Computation · doi:10.1090/s0025-5718-1982-0637296-4 · Cited by 1,895
Numerical recipes: The art of scientific computing
DAVIDROPER, L. (1987) · Bulletin of Mathematical Biology · doi:10.1016/s0092-8240(87)90019-x · Cited by 1,424
Nonlinear anisotropic filtering of MRI data
Gerig, G., Kubler, O., Kikinis, R., & Jolesz, F. A. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.141646 · Cited by 1,149
Interpolation using surface splines.
HARDER, R. L., & DESMARAIS, R. N. (1972) · Journal of Aircraft · doi:10.2514/3.44330 · Cited by 770
Hall, L. O., Bensaid, A. M., Clarke, L. P., Velthuizen, R. P., Silbiger, M. S., & Bezdek, J. C. (1992) · IEEE Transactions on Neural Networks · doi:10.1109/72.159057 · Cited by 580
Interpolation des fonctions de deux variables suivant le principe de la flexion des plaques minces
Duchon, J. (1976) · Revue française d'automatique, informatique, recherche opérationnelle. Analyse numérique · doi:10.1051/m2an/197610r300051 · Cited by 484
Scattered Data Interpolation: Tests of Some Method
Franke, R. (1982) · Mathematics of Computation · doi:10.2307/2007474 · Cited by 443
Multivariate interpolation at arbitrary points made simple
Meinguet, J. (1979) · Zeitschrift für angewandte Mathematik und Physik ZAMP · doi:10.1007/bf01601941 · Cited by 413
Segmentation of MR Brain Images into Cerebrospinal Fluid Spaces, White and Gray Matter
Lim, K. O., & Pfefferbaum, A. (1989) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198907000-00006 · Cited by 309
Kohn, M. I., Tanna, N. K., Herman, G. T., Resnick, S. M., Mozley, P. D., Gur, R. E., Alavi, A., Zimmerman, R. A., & Gur, R. C. (1991) · Radiology · doi:10.1148/radiology.178.1.1984289 · Cited by 273
Multispectral analysis of magnetic resonance images.
Vannier, M. W., Butterfield, R. L., Jordan, D., Murphy, W. A., Levitt, R. G., & Gado, M. (1985) · Radiology · doi:10.1148/radiology.154.1.3964938 · Cited by 253
Intensity correction in surface-coil MR imaging
Axel, L., Costantini, J., & Listerud, J. (1987) · American Journal of Roentgenology · doi:10.2214/ajr.148.2.418 · Cited by 240
Neural-network-based segmentation of multi-modal medical images: a comparative and prospective study
Ozkan, M., Dawant, B. M., & Maciunas, R. J. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.241881 · Cited by 211
Self-citationOptimization neural networks for the segmentation of magnetic resonance images
Amartur, S. C., Piraino, D., & Takefuji, Y. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.141645 · Cited by 162
Comparison of Magnetic Resonance Imaging in Alzheimer’s Disease, Vascular Dementia and Normal Aging
Schmidt, R. (2008) · European Neurology · doi:10.1159/000116816 · Cited by 103
Correction for intensity falloff in surface coil magnetic resonance imaging
Brey, W. W., & Narayana, P. A. (1988) · Medical Physics · doi:10.1118/1.596255 · Cited by 89
Information Processing in Medical Imaging
Bacharach, S. L. (1986) · Springer eBooks · doi:10.1007/978-94-009-4261-5 · Cited by 68
Automatic detection of intracranial contours in MR images
Zijdenbos, A. P., Dawant, B. M., & Margolin, R. A. (1994) · Computerized Medical Imaging and Graphics · doi:10.1016/0895-6111(94)90057-4 · Cited by 37
Self-citation
Cited by
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
“This model has been widely used [14]–[16], [18] and is consistent with the multiplicative nonuniformity arising from variations in the sensitivity of the reception coil and to a lesser extent with the nonuniformity due to induced currents and nonuniform excitation.”
MethodSelf-citationCurrent Methods in Medical Image Segmentation
Pham, D. L., Xu, C., & Prince, J. L. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.315 · Cited by 2,341
A modified fuzzy c-means algorithm for bias field estimation and segmentation of MRI data
Ahmed, M. N., Yamany, S. M., Mohamed, N., Farag, A. A., & Moriarty, T. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.996338 · Cited by 1,792
Adaptive segmentation of MRI data
Wells, W. M., Grimson, W. E. L., Kikinis, R., & Jolesz, F. A. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.511747 · Cited by 1,277
Morphometric analysis of white matter lesions in MR images: method and validation
Zijdenbos, A. P., Dawant, B. M., Margolin, R. A., & Palmer, A. C. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363096 · Cited by 1,265
Self-citation
Metadata
- Authors
- Dawant, B. M., Zijdenbos, A. P., & Margolin, R. A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1993
- Volume
- 12
- Issue
- 4
- Pages
- 770-781
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2115772934
- Cited by
- 291
- References
- 20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.