The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Tissue elasticity reconstruction using linear perturbation method
Abstract
A new method to reconstruct the elastic modulus of soft tissue subjected to an external static compression is presented. In this approach the Newton-Raphson method is used to vary a finite element (FE) model of the elasticity equations to fit, in a least squared sense, a set of axial tissue displacement fields estimated using a correlation technique applied to ultrasound signals. The ill-conditioning of the Hessian matrix is eliminated using the Tikhonov regularization technique. This regularization provides a compromise between fidelity to the observed data and a priori information of the solution. Using an echographic image formation model, it is shown that the method converges within a few iterations (8-10) and that strain images artifacts which are common in elastography are significantly reduced after the resolution of the inverse problem.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cross validatory choice and assessment of statistical predictions
Stone, M. (1974) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1974.tb00994.x · Cited by 10,881
Levary, R. R. (1982) · European Journal of Operational Research · doi:10.1016/0377-2217(82)90093-5 · Cited by 4,158
Generalized Cross-Validation as a Method for Choosing a Good Ridge Parameter
Golub, G. H., Heath, M., & Wahba, G. (1979) · Technometrics · doi:10.1080/00401706.1979.10489751 · Cited by 3,934
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Introduction to the Finite Element Method
(2021) · Finite Element Method for Solids and Structures · doi:10.1017/9781108683982.002 · Cited by 2,933
Numerical Solution of Partial Differential Equations, Finite Difference Methods.
T., V., & Smith, G. D. (1987) · Mathematics of Computation · doi:10.2307/2007849 · Cited by 2,016
Ill-posed problems in early vision
Bertero, M., Poggio, T. A., & Torre, V. (1988) · Proceedings of the IEEE · doi:10.1109/5.5962 · Cited by 723
Internal displacement and strain imaging using ultrasonic speckle tracking
O'Donnell, M., Skovoroda, A. R., Shapo, B. M., & Emelianov, S. Y. (1994) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.285465 · Cited by 699
Image reconstruction and restoration: overview of common estimation structures and problems
Demoment, G. (1989) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/29.45551 · Cited by 647
Comparing Reconstruction Algorithms for Electrical Impedance Tomography
Yorkey, T. J., Webster, J. G., & Tompkins, W. J. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326032 · Cited by 596
Galatsanos, N. P., & Katsaggelos, A. K. (1992) · IEEE Transactions on Image Processing · doi:10.1109/83.148606 · Cited by 500
Tissue response to mechanical vibrations for “sonoelasticity imaging”
Parker, K. J., Huang, S. R., Musulin, R. A., & Lerner, R. M. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90003-u · Cited by 478
Elastography: Elasticity Imaging Using Ultrasound with Application to Muscle and Breast In Vivo
Cespedes, I. (1993) · Ultrasonic Imaging · doi:10.1006/uimg.1993.1007 · Cited by 414
Fundamental limitations in passive time delay estimation--Part I: Narrow-band systems
Weiss, A., & Weinstein, E. (1983) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1983.1164061 · Cited by 348
Hein, I. A., & O'Brien, W. D. (1993) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.212556 · Cited by 309
A study of methods of choosing the smoothing parameter in image restoration by regularization
Thompson, A. M., Brown, J. C., Kay, J. W., & Titterington, D. M. (1991) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.88568 · Cited by 305
Elastography: Ultrasonic imaging of tissue strain and elastic modulus in vivo
Ophir, J., Cespedes, I., Garra, B., Ponnekanti, H., Huang, Y., & Maklad, N. (1996) · European Journal of Ultrasound · doi:10.1016/0929-8266(95)00134-4 · Cited by 287
Ultrasonic B-scanning: a computer simulation
Bamber, J. C., & Dickinson, R. J. (1980) · Physics in Medicine & Biology · doi:10.1088/0031-9155/25/3/006 · Cited by 223
Fundamental limitations in passive time-delay estimation--Part II: Wide-band systems
Weinstein, E., & Weiss, A. (1984) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1984.1164429 · Cited by 222
Reduction of Image Noise in Elastography
Céspedes, I., & Ophir, J. (1993) · Ultrasonic Imaging · doi:10.1177/016173469301500202 · Cited by 199
Ultrasonic texture motion analysis: theory and simulation
Meunier, J., & Bertrand, M. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.387711 · Cited by 191
Self-citationNashed, M. (1981) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.1981.1142564 · Cited by 167
The inverse problem in electrocardiography: solutions in terms of equivalent sources.
Gulrajani, R. M., Savard, P., & ROBERGE, F. A. (1988) · PubMed · Cited by 59
A note on strain estimation using correlation techniques [tissue]
Kallel, F., & Bertrand, M. (1993) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.1993.339664 · Cited by 8
Self-citation
Cited by
Magnetic resonance elastography: Non-invasive mapping of tissue elasticity
Manduca, A., Oliphant, T. E., Dresner, M. A., Mahowald, J. L., Kruse, S. A., Amromin, E., Felmlee, J. P., Greenleaf, J. F., & Ehman, R. L. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00039-6 · Cited by 1,103
Elastography: Ultrasonic estimation and imaging of the elastic properties of tissues
Ophir, J., Alam, S. K., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., & Varghese, T. (1999) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411991534933 · Cited by 784
Self-citationSelected Methods for Imaging Elastic Properties of Biological Tissues
Greenleaf, J. F., Fatemi, M., & Insana, M. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121623 · Cited by 671
Phantom materials for elastography
Hall, T. J., Bilgen, M., Insana, M. F., & Krouskop, T. A. (1997) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.656639 · Cited by 516
Konofagou, E., & Ophir, J. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00109-4 · Cited by 444
Metadata
- Authors
- Kallel, F., & Bertrand, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1996-06
- Volume
- 15
- Issue
- 3
- Pages
- 299-313
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2139465203
- Cited by
- 329
- References
- 24
- FWCI
- 9.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.