The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Bayesian reconstructions from emission tomography data using a modified EM algorithm
Abstract
A novel method of reconstruction from single-photon emission computerized tomography data is proposed. This method builds on the expectation-maximization (EM) approach to maximum likelihood reconstruction from emission tomography data, but aims instead at maximum posterior probability estimation, which takes account of prior belief about smoothness in the isotope concentration. A novel modification to the EM algorithm yields a practical method. The method is illustrated by an application to data from brain scans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
A Statistical Model for Positron Emission Tomography
Vardi, Y., Shepp, L. A., & Kaufman, L. (1985) · Journal of the American Statistical Association · doi:10.1080/01621459.1985.10477119 · Cited by 863
Cited by
Constrained restoration and the recovery of discontinuities
Geman, D., & Reynolds, G. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.120331 · Cited by 1,085
Nonlinear image recovery with half-quadratic regularization
Geman, D., & Yang, C. (1995) · IEEE Transactions on Image Processing · doi:10.1109/83.392335 · Cited by 1,000
Fully 3-D PET reconstruction with system matrix derived from point source measurements
Panin, V. Y., Kehren, F., Michel, C., & Casey, M. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.876171 · Cited by 536
STIR: software for tomographic image reconstruction release 2
Thielemans, K., Tsoumpas, C., Mustafovic, S., Beisel, T., Aguiar, P., Dikaios, N., & Jacobson, M. W. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/4/867 · Cited by 466
Socioeconomic status determines COVID-19 incidence and related mortality in Santiago, Chile
Mena, G. E., Martinez, P. P., Mahmud, A. S., Marquet, P. A., Buckee, C. O., & Santillana, M. (2021) · Science · doi:10.1126/science.abg5298 · Cited by 431
Metadata
- Authors
- Green, P. J.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1990-03
- Volume
- 9
- Issue
- 1
- Pages
- 84-93
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2168530812
- Cited by
- 1,241
- References
- 2
- FWCI
- 18.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bayesian reconstructions from emission tomography data using a modified EM algorithm. https://app.cochat.ai/papers/10.1109/42.52985
- The paper
- Green, P. J. (1990). Bayesian reconstructions from emission tomography data using a modified EM algorithm. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.52985
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.