The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Bayesian reconstructions from emission tomography data using a modified EM algorithm
Abstract
A novel method of reconstruction from single-photon emission computerized tomography data is proposed. This method builds on the expectation-maximization (EM) approach to maximum likelihood reconstruction from emission tomography data, but aims instead at maximum posterior probability estimation, which takes account of prior belief about smoothness in the isotope concentration. A novel modification to the EM algorithm yields a practical method. The method is illustrated by an application to data from brain scans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stochastic relaxation, gibbs distributions, and the bayesian restoration of images.
Geman, S., & Geman, D. (1984) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1984.4767596 · Cited by 17,949
Nelder, J. A., & Wedderburn, R. W. M. (1972) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2344614 · Cited by 7,194
Maximum likelihood estimation from incomplete data via the EM algorithm
Dempster, A. P. (1977) · Journal of the Royal Statistical Society Series A (Statistics in Society) · Cited by 4,543
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
A Statistical Model for Positron Emission Tomography
Vardi, Y., Shepp, L. A., & Kaufman, L. (1985) · Journal of the American Statistical Association · doi:10.1080/01621459.1985.10477119 · Cited by 863
Statistical methods for tomographic image reconstruction
Geman, S., & McClure, D. E. (1987) · Medical Entomology and Zoology · Cited by 579
Levitan, E., & Herman, G. T. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307826 · Cited by 445
On Use of the Em Algorithm for Penalized Likelihood Estimation
Green, P. J. (1990) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1990.tb01798.x · Cited by 417
Self-citationNon-parametric Roughness Penalty for Probability Densities
GOOD, I. J. (1971) · Nature Physical Science · doi:10.1038/physci229029a0 · Cited by 411
A Theoretical Study of Some Maximum Likelihood Algorithms for Emission and Transmission Tomography
Lange, K., Bahn, M., & Little, R. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307810 · Cited by 330
Nonparametric Roughness Penalties for Probability Densities
Good, I. J., & Gaskins, R. A. (1971) · Biometrika · doi:10.2307/2334515 · Cited by 315
Implementing and Accelerating the EM Algorithm for Positron Emission Tomography
Kaufman, L. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307796 · Cited by 293
The Use of Sieves to Stabilize Images Produced with the EM Algorithm for Emission Tomography
Snyder, D. L., & Miller, M. I. (1985) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1985.4334521 · Cited by 278
Silverman, B. W., Jones, M. C., Wilson, J. D., & Nychka, D. W. (1990) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1990.tb01788.x · Cited by 274
Stopping Rule for the MLE Algorithm Based on Statistical Hypothesis Testing
Veklerov, E., & Llacer, J. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307849 · Cited by 254
Inverse Monte Carlo: A Unified Reconstruction Algorithm for SPECT
Floyd, C. E., Jaszczak, R. J., & Coleman, R. E. (1985) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1985.4336940 · Cited by 196
Lewitt, R. M., & Muehllehner, G. (1986) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1986.4307734 · Cited by 155
Speed of Estimation in Positron Emission Tomography and Related Inverse Problems
Johnstone, I. M., & Silverman, B. W. (1990) · The Annals of Statistics · doi:10.1214/aos/1176347500 · Cited by 142
SPECT: Single Photon Emission Computed Tomography
Jaszczak, R. J., Coleman, R. E., & Lim, C. B. (1980) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1980.4330986 · Cited by 120
Veklerov, E., Llacer, J., & Hoffman, E. J. (1988) · IEEE Transactions on Nuclear Science · doi:10.1109/23.12795 · Cited by 89
Tanaka, E. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307809 · Cited by 81
Some properties of adding a smoothing step to the EM algorithm
Nychka, D. W. (1990) · Statistics & Probability Letters · doi:10.1016/0167-7152(92)90015-w · Cited by 40
New Insights into Emission Tomography Via Linear Programming
Shepp, L. A., & Vanderbei, R. J. (1992) · Springer eBooks · doi:10.1007/978-3-642-77888-9_3 · Cited by 8
Cited by
Bayesian image restoration, with two applications in spatial statistics
Besag, J., York, J., & Molli�, A. (1991) · Annals of the Institute of Statistical Mathematics · doi:10.1007/bf00116466 · Cited by 4,205
Accelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,711
Deterministic edge-preserving regularization in computed imaging
Charbonnier, P., Blanc-Feraud, L., Aubert, G., & Barlaud, M. (1997) · IEEE Transactions on Image Processing · doi:10.1109/83.551699 · Cited by 1,301
Percival, D. B. (1989) · Technometrics · doi:10.1080/00401706.1989.10488494 · Cited by 1,234
Ollinger, J. M., & Fessler, J. A. (1997) · IEEE Signal Processing Magazine · doi:10.1109/79.560323 · Cited by 1,167
Metadata
- Authors
- Green, P. J.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1990-03
- Volume
- 9
- Issue
- 1
- Pages
- 84-93
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2168530812
- Cited by
- 1,241
- References
- 24
- FWCI
- 18.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.