Classification of mass and normal breast tissue: a convolution neural network classifier with spatial domain and texture images
Abstract
The authors investigated the classification of regions of interest (ROI's) on mammograms as either mass or normal tissue using a convolution neural network (CNN). A CNN is a backpropagation neural network with two-dimensional (2-D) weight kernels that operate on images. A generalized, fast and stable implementation of the CNN was developed. The input images to the CNN were obtained from the ROI's using two techniques. The first technique employed averaging and subsampling. The second technique employed texture feature extraction methods applied to small subregions inside the ROI. Features computed over different subregions were arranged as texture images, which were subsequently used as CNN inputs. The effects of CNN architecture and texture feature parameters on classification accuracy were studied. Receiver operating characteristic (ROC) methodology was used to evaluate the classification accuracy. A data set consisting of 168 ROIs containing biopsy-proven masses and 504 ROI's containing normal breast tissue was extracted from 168 mammograms by radiologists experienced in mammography. This data set was used for training and testing the CNN. With the best combination of CNN architecture and texture feature parameters, the area under the test ROC curve reached 0.87, which corresponded to a true-positive fraction of 90% at a false positive fraction of 31%. The authors' results demonstrate the feasibility of using a CNN for classification of masses and normal tissue on mammograms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886
30 years of adaptive neural networks: perceptron, Madaline, and backpropagation
Widrow, B., & Lehr, M. A. (1990) · Proceedings of the IEEE · doi:10.1109/5.58323 · Cited by 2,242
Increased rates of convergence through learning rate adaptation
Jacobs, R. A. (1988) · Neural Networks · doi:10.1016/0893-6080(88)90003-2 · Cited by 1,806
ROC Methodology in Radiologic Imaging
METZ, C. E. (1986) · Investigative Radiology · doi:10.1097/00004424-198609000-00009 · Cited by 1,642
A Comparative Study of Texture Measures for Terrain Classification
Weszka, J. S., Dyer, C. R., & Rosenfeld, A. (1976) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1976.5408777 · Cited by 1,522
Boring, C. C., Squires, T. S., Tong, T., & Montgomery, S. (1994) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.44.1.7 · Cited by 1,315
Analysis of cancers missed at screening mammography.
Bird, R. E., Wallace, T. W., & Yankaskas, B. C. (1992) · Radiology · doi:10.1148/radiology.184.3.1509041 · Cited by 820
Neocognitron: A neural network model for a mechanism of visual pattern recognition
Fukushima, K., Miyake, S., & Ito, T. (1983) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1983.6313076 · Cited by 713
Wu, Y., Giger, M. L., Doi, K., Vyborny, C. J., Schmidt, R. A., & Metz, C. E. (1993) · Radiology · doi:10.1148/radiology.187.1.8451441 · Cited by 421
CHAN, H.-P., DOI, K., VYBRONY, C. J., SCHMIDT, R. A., METZ, C. E., LAM, K. L., OGURA, T., WU, Y., & MACMAHON, H. (1990) · Investigative Radiology · doi:10.1097/00004424-199010000-00006 · Cited by 359
Self-citationComputer-aided mammographic screening for spiculated lesions.
Kegelmeyer, W. P., Pruneda, J. M., Bourland, P. D., Hillis, A., Riggs, M. W., & Nipper, M. L. (1994) · Radiology · doi:10.1148/radiology.191.2.8153302 · Cited by 278
An approach to automated detection of tumors in mammograms
Brzakovic, D., Luo, X. M., & Brzakovic, P. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.57760 · Cited by 246
On techniques for detecting circumscribed masses in mammograms
Lai, S.-M., Li, X., & Biscof, W. F. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.41491 · Cited by 239
Chan, H.-P., Wei, D., Helvie, M. A., Sahiner, B., Adler, D. D., Goodsitt, M. M., & Petrick, N. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/5/010 · Cited by 208
Self-citationChan, H., Lo, S. B., Sahiner, B., Lam, K. L., & Helvie, M. A. (1995) · Medical Physics · doi:10.1118/1.597428 · Cited by 208
Self-citationComputerized detection of masses in digital mammograms: Analysis of bilateral subtraction images
Yin, F., Giger, M. L., Doi, K., Metz, C. E., Vyborny, C. J., & Schmidt, R. A. (1991) · Medical Physics · doi:10.1118/1.596610 · Cited by 196
Zhang, W., Doi, K., Giger, M. L., Wu, Y., Nishikawa, R. M., & Schmidt, R. A. (1994) · Medical Physics · doi:10.1118/1.597177 · Cited by 168
Wu, Y. C., Doi, K., Giger, M. L., et al. (1992) · Medical Physics · doi:10.1118/1.596845 · Cited by 143
Shih-Chung, B. L., Freedman, M. T., Lin, J.-S., & Mun, S. K. (1993) · Journal of Digital Imaging · doi:10.1007/bf03168418 · Cited by 94
Breast cancer detection: one versus two views.
Bassett, L. W., Bunnell, D. H., Jahanshahi, R., Gold, R. H., Arndt, R., & Linsman, J. (1987) · Radiology · doi:10.1148/radiology.165.1.3628795 · Cited by 77
Computer-assisted diagnosis of lung nodule detection using artificial convoultion neural network
Lo, S. B., Lin, J.-S., Freedman, M. T., & Mun, S. K. (1993) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.154572 · Cited by 64
Computer-assisted diagnosis for lung nodule detection using a neural network technique
Lo, S. B., Freedman, M. T., Lin, J.-S., Krasner, B. H., & Mun, S. K. (1992) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.59479 · Cited by 3
Cited by
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332
Artificial intelligence in cancer imaging: Clinical challenges and applications
Bi, W. L., Hosny, A., Schabath, M. B., Giger, M. L., Birkbak, N. J., Mehrtash, A., Allison, T., Arnaout, O., Abbosh, C., Dunn, I. F., et al. (2019) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21552 · Cited by 1,846
Greenspan, H., van Ginneken, B., & Summers, R. M. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2553401 · Cited by 1,700
Overview of deep learning in medical imaging
Suzuki, K. (2017) · Radiological Physics and Technology · doi:10.1007/s12194-017-0406-5 · Cited by 1,087
Large scale deep learning for computer aided detection of mammographic lesions
Kooi, T., Litjens, G., van Ginneken, B., Gubern-Mérida, A., Sánchez, C. I., Mann, R., den Heeten, A., & Karssemeijer, N. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.07.007 · Cited by 965
Metadata
- Authors
- Sahiner, B., Chan, H.-P., Petrick, N., Wei, D., Helvie, M. A., Adler, D. D., & Goodsitt, M. M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1996
- Volume
- 15
- Issue
- 5
- Pages
- 598-610
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W1988452762
- Cited by
- 420
- References
- 22
- FWCI
- 8.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.