A geometric snake model for segmentation of medical imagery
Abstract
In this note, we employ the new geometric active contour models formulated in [25] and [26] for edge detection and segmentation of magnetic resonance imaging (MRI), computed tomography (CT), and ultrasound medical imagery. Our method is based on defining feature-based metrics on a given image which in turn leads to a novel snake paradigm in which the feature of interest may be considered to lie at the bottom of a potential well. Thus, the snake is attracted very quickly and efficiently to the desired feature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kass, M., Witkin, A., & Terzopoulos, D. (1988) · International Journal of Computer Vision · doi:10.1007/bf00133570 · Cited by 17,070
Fronts propagating with curvature-dependent speed: Algorithms based on Hamilton-Jacobi formulations
Osher, S., & Sethian, J. A. (1988) · Journal of Computational Physics · doi:10.1016/0021-9991(88)90002-2 · Cited by 14,062
Scale-space and edge detection using anisotropic diffusion
Perona, P., & Malik, J. (1990) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.56205 · Cited by 12,119
User’s guide to viscosity solutions of second order partial differential equations
Crandall, M. G., Ishii, H., & Lions, P.-L. (1992) · Bulletin of the American Mathematical Society · doi:10.1090/s0273-0979-1992-00266-5 · Cited by 4,781
Differential geometry of curves and surfaces
(2011) · Choice Reviews Online · doi:10.5860/choice.48-3330 · Cited by 3,706
Numerical Methods for Conservation Laws
LeVeque, R. J. (1992) · Birkhäuser Basel eBooks · doi:10.1007/978-3-0348-8629-1 · Cited by 3,632
Maximum Principles in Differential Equations
Protter, M. H., & Weinberger, H. F. (1984) · Springer eBooks · doi:10.1007/978-1-4612-5282-5 · Cited by 3,578
A Comprehensive Introduction to Differential Geometry.
Kramer, A. D., & Spivak, M. (1973) · The American Mathematical Monthly · doi:10.2307/2319112 · Cited by 3,445
Shape modeling with front propagation: a level set approach
Malladi, R., Sethian, J. A., & Vemuri, B. C. (1995) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.368173 · Cited by 3,158
Eisenhart, L. P. (1950) · Princeton University Press eBooks · doi:10.1515/9781400884216 · Cited by 2,506
Cited by
Medical image analysis: progress over two decades and the challenges ahead
Duncan, J. S., & Ayache, N. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824822 · Cited by 4,140
Graph Cuts and Efficient N-D Image Segmentation
Boykov, Y., & Funka-Lea, G. (2006) · International Journal of Computer Vision · doi:10.1007/s11263-006-7934-5 · Cited by 1,910
A shape-based approach to the segmentation of medical imagery using level sets
Tsai, A., Yezzi, A., Wells, W., Tempany, C., Tucker, D., Fan, A., Grimson, W. E., & Willsky, A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.808355 · Cited by 894
Self-citationFast Global Minimization of the Active Contour/Snake Model
Bresson, X., Esedoḡlu, S., Vandergheynst, P., Thiran, J.-P., & Osher, S. (2007) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-007-0002-0 · Cited by 857
Tsai, A., Yezzi, A., & Willsky, A. S. (2001) · IEEE Transactions on Image Processing · doi:10.1109/83.935033 · Cited by 841
Self-citationA review of segmentation methods in short axis cardiac MR images
Petitjean, C., & Dacher, J.-N. (2011) · Medical Image Analysis · doi:10.1016/j.media.2010.12.004 · Cited by 737
State of the art survey on MRI brain tumor segmentation
Gordillo, N., Montseny, E., & Sobrevilla, P. (2013) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2013.05.002 · Cited by 697
“So, Kichenas-samy et al. [98] and Yezzi et al. [99] added a term to ef fi ciently attract the evolving contour to the desired feature.”
BackgroundBlood vessel segmentation algorithms — Review of methods, datasets and evaluation metrics
Moccia, S., De Momi, E., El Hadji, S., & Mattos, L. S. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.02.001 · Cited by 567
Computing geodesics and minimal surfaces via graph cuts
Boykov, & Kolmogorov (2003) · Proceedings Ninth IEEE International Conference on Computer Vision · doi:10.1109/iccv.2003.1238310 · Cited by 555
Three-dimensional modeling for functional analysis of cardiac images, a review
Frangi, A. F., Niessen, W. J., & Viergever, M. A. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906421 · Cited by 533
Xing, F., & Yang, L. (2016) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2016.2515127 · Cited by 519
Topology preserving level set method for geometric deformable models
Han, X., Xu, C., & Prince, J. L. (2003) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2003.1201824 · Cited by 492
Geometric Applications of the Split Bregman Method: Segmentation and Surface Reconstruction
Goldstein, T., Bresson, X., & Osher, S. (2010) · Journal of Scientific Computing · doi:10.1007/s10915-009-9331-z · Cited by 452
Conformal curvature flows: From phase transitions to active vision
Kichenassamy, S., Kumar, A., Olver, P., Tannenbaum, A., & Yezzi, A. (1996) · Archive for Rational Mechanics and Analysis · doi:10.1007/bf00379537 · Cited by 418
Self-citationUsing Prior Shapes in Geometric Active Contours in a Variational Framework
Chen, Y., Tagare, H. D., Thiruvenkadam, S., Huang, F., Wilson, D., Gopinath, K. S., Briggs, R. W., & Geiser, E. A. (2002) · International Journal of Computer Vision · doi:10.1023/a:1020878408985 · Cited by 406
Deformable models in medical image analysis
McInerney, T., & Terzopoulos, D. (1996) · Proceedings of the Workshop on Mathematical Methods in Biomedical Image Analysis · doi:10.1109/mmbia.1996.534069 · Cited by 329
Image Segmentation Using Active Contours Driven by the Bhattacharyya Gradient Flow
Michailovich, O., Rathi, Y., & Tannenbaum, A. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.908073 · Cited by 320
Self-citationShape recovery algorithms using level sets in 2-D/3-D medical imagery: a state-of-the-art review
Suri, J. S., Liu, K., Singh, S., Laxminarayan, S. N., Zeng, X., & Reden, L. (2002) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.992158 · Cited by 312
A Fully Global Approach to Image Segmentation via Coupled Curve Evolution Equations
Yezzi, A., Tsai, A., & Willsky, A. (2002) · Journal of Visual Communication and Image Representation · doi:10.1006/jvci.2001.0500 · Cited by 304
Self-citationKim, J., Fisher, J. W., Yezzi, A., Cetin, M., & Willsky, A. S. (2005) · IEEE Transactions on Image Processing · doi:10.1109/tip.2005.854442 · Cited by 301
Self-citationImage-guided control of a robot for medical ultrasound
Abolmaesumi, P., Salcudean, S. E., Zhu, W.-H., Sirouspour, M. R., & DiMaio, S. P. (2002) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.988970 · Cited by 296
Automatic breast ultrasound image segmentation: a survey
Xian, M., Zhang, Y., Cheng, H. D., Xu, F., Zhang, B., & Ding, J. (2018) · Pattern Recognition · doi:10.1016/j.patcog.2018.02.012 · Cited by 284
“In edge-based DMs, [42, 50, 52, 56 - 59, 61 - 63], image gradient is applied to constructing the external force or speed function of the evolving curve; as discussed in section 3.”
BackgroundMethodInfluentialArea and length minimizing flows for shape segmentation
Siddiqi, K., Lauziere, Y. B., Tannenbaum, A., & Zucker, S. W. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.661193 · Cited by 261
Self-citationA comparative study of deformable contour methods on medical image segmentation
He, L., Peng, Z., Everding, B., Wang, X., Han, C. Y., Weiss, K. L., & Wee, W. G. (2008) · Image and Vision Computing · doi:10.1016/j.imavis.2007.07.010 · Cited by 257
On the relationship between parametric and geometric active contours
Xu, C., Yezzi, A., & Prince, J. L. (2002) · Conference Record of the Thirty-Fourth Asilomar Conference on Signals, Systems and Computers (Cat. No.00CH37154) · doi:10.1109/acssc.2000.911003 · Cited by 252
Self-citationA Likelihood and Local Constraint Level Set Model for Liver Tumor Segmentation from CT Volumes
Li, C., Wang, X., Eberl, S., Fulham, M., Yin, Y., Chen, J., & Feng, D. D. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2267212 · Cited by 139
Multi-classifier framework for atlas-based image segmentation
Rohlfing, T., & Maurer, C. R. (2005) · Pattern Recognition Letters · doi:10.1016/j.patrec.2005.03.017 · Cited by 80
Metadata
- Authors
- Yezzi, A., Kichenassamy, S., Kumar, A., Olver, P., & Tannenbaum, A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1997-04
- Volume
- 16
- Issue
- 2
- Pages
- 199-209
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2161237731
- Cited by
- 581
- References
- 35
- FWCI
- 17.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.