MEG-based imaging of focal neuronal current sources
Abstract
We describe a new approach to imaging neural current sources from measurements of the magnetoencephalogram (MEG) associated with sensory, motor, or cognitive brain activation. Many previous approaches to this problem have concentrated on the use of weighted minimum norm (WMN) inverse methods. While these methods ensure a unique solution, they do not introduce information specific to the MEG inverse problem, often producing overly smoothed solutions and exhibiting severe sensitivity to noise. We describe a Bayesian formulation of the inverse problem in which a Gibbs prior is constructed to reflect the sparse focal nature of neural current sources associated with evoked response data. We demonstrate the method with simulated and experimental phantom data, comparing its performance with several WMN methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stochastic relaxation, gibbs distributions, and the bayesian restoration of images.
Geman, S., & Geman, D. (1984) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1984.4767596 · Cited by 17,949
Multiple emitter location and signal parameter estimation
Schmidt, R. (1986) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.1986.1143830 · Cited by 14,718 · cited 1×
“The multiple signal classification (MUSIC) algorithm [13] avoids some of the problems due to this nonconvexity through the use of signal subspace techniques [14].”
MethodStatistical Decision Theory and Bayesian Analysis
Berger, J. O. (1985) · Springer Series in Statistics · doi:10.1007/978-1-4757-4286-2 · Cited by 7,722
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Analysis of Discrete Ill-Posed Problems by Means of the L-Curve
Hansen, P. C. (1992) · SIAM Review · doi:10.1137/1034115 · Cited by 3,903
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Dale, A. M., & Sereno, M. I. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.2.162 · Cited by 2,003
Wang, J.-Z., Williamson, S. J., & Kaufman, L. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.142641 · Cited by 299
Selective minimum-norm solution of the biomagnetic inverse problem
Matsuura, K., & Okabe, Y. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.387200 · Cited by 243
Cited by
Brainstorm: A User-Friendly Application for MEG/EEG Analysis
Tadel, F., Baillet, S., Mosher, J. C., Pantazis, D., & Leahy, R. M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/879716 · Cited by 3,677
Self-citationBaillet, S., Mosher, J. C., & Leahy, R. M. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962275 · Cited by 1,692
Self-citationMichel, C. M., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & Grave de Peralta, R. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,655
Sparse solutions to linear inverse problems with multiple measurement vectors
Cotter, S. F., Rao, B. D., Engan, K., & Kreutz-Delgado, K. (2005) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2005.849172 · Cited by 1,393
Structured Compressed Sensing: From Theory to Applications
Duarte, M. F., & Eldar, Y. C. (2011) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2011.2161982 · Cited by 1,128
An Empirical Bayesian Strategy for Solving the Simultaneous Sparse Approximation Problem
Wipf, D. P., & Rao, B. D. (2007) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2007.894265 · Cited by 911
EEG and MEG: forward solutions for inverse methods
Mosher, J. C., Leahy, R. M., & Lewis, P. S. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.748978 · Cited by 839
Self-citationPascual-Marqui, R. D., Lehmann, D., Koenig, T., Kochi, K., Merlo, M. C. G., Hell, D., & Koukkou, M. (1999) · Psychiatry Research: Neuroimaging · doi:10.1016/s0925-4927(99)00013-x · Cited by 617
Linear and Nonlinear Current Density Reconstructions
Fuchs, M., Wagner, M., Köhler, T., & Wischmann, H.-A. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199905000-00006 · Cited by 436
A study of dipole localization accuracy for MEG and EEG using a human skull phantom
Leahy, R. M., Mosher, J. C., Spencer, M. E., Huang, M. X., & Lewine, J. D. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00057-1 · Cited by 383
Self-citationMonte Carlo simulation studies of EEG and MEG localization accuracy
Liu, A. K., Dale, A. M., & Belliveau, J. W. (2002) · Human Brain Mapping · doi:10.1002/hbm.10024 · Cited by 349
Mapping human brain function with MEG and EEG: methods and validation
Darvas, F., Pantazis, D., Kucukaltun-Yildirim, E., & Leahy, R. M. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.014 · Cited by 310
Self-citationReconstructing cortical current density by exploring sparseness in the transform domain
Ding, L. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/9/006 · Cited by 99
Electrophysiological Mapping and Neuroimaging
He, B., & Ding, L. (2013) · Neural Engineering · doi:10.1007/978-1-4614-5227-0_12 · Cited by 26
Metadata
- Authors
- Phillips, J. W., Leahy, R. M., & Mosher, J. C.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1997-06
- Volume
- 16
- Issue
- 3
- Pages
- 338-348
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2152652881
- Cited by
- 190
- References
- 9
- FWCI
- 4.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.