The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Linear and Nonlinear Current Density Reconstructions
Abstract
Minimum norm algorithms for EEG source reconstruction are studied in view of their spatial resolution, regularization, and lead-field normalization properties, and their computational efforts. Two classes of minimum norm solutions are examined: linear least squares methods and nonlinear L1-norm approaches. Two special cases of linear algorithms, the well known Minimum Norm Least Squares and an implementation with Laplacian smoothness constraints, are compared to two nonlinear algorithms comprising sparse and standard L1-norm methods. In a signal-to-noise-ratio framework, two of the methods allow automatic determination of the optimum regularization parameter. Compensation methods for the different depth dependencies of all approaches by lead-field normalization are discussed. Simulations with tangentially and radially oriented test dipoles at two different noise levels are performed to reveal and compare the properties of all approaches. Finally, cortically constrained versions of the algorithms are applied to two epileptic spike data sets and compared to results of single equivalent dipole fits and spatiotemporal source models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simplex Method for Function Minimization
Nelder, J. A., & Mead, R. (1965) · The Computer Journal · doi:10.1093/comjnl/7.4.308 · Cited by 28,905
Analysis of Discrete Ill-Posed Problems by Means of the L-Curve
Hansen, P. C. (1992) · SIAM Review · doi:10.1137/1034115 · Cited by 3,903
Automatic 3D intersubject registration of MR volumetric data in standardized Talairach space
Collins, D. L., Neelin, P., Peters, T. M., & Evans, A. C. (1994) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199403000-00005 · Cited by 3,431
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Dale, A. M., & Sereno, M. I. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.2.162 · Cited by 2,003
Interpreting magnetic fields of the brain: minimum norm estimates
Hämäläinen, M. S., & Ilmoniemi, R. J. (1994) · Medical & Biological Engineering & Computing · doi:10.1007/bf02512476 · Cited by 1,995
Multiple dipole modeling and localization from spatio-temporal MEG data
Mosher, J. C., Lewis, P. S., & Leahy, R. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141192 · Cited by 1,048
Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989
Numerical Applications of a Formalism for Geophysical Inverse Problems
Backus, G. E., & Gilbert, J. F. (1967) · Geophysical Journal International · doi:10.1111/j.1365-246x.1967.tb02159.x · Cited by 943
Two bilateral sources of the late AEP as identified by a spatio-temporal dipole model
Scherg, M., & Von Cramon, D. (1985) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(85)90033-4 · Cited by 683
Cited by
Spatiotemporal Analysis of Multichannel EEG: CARTOOL
Brunet, D., Murray, M. M., & Michel, C. M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/813870 · Cited by 731
Multiple sparse priors for the M/EEG inverse problem.
Friston, K., Harrison, L., Daunizeau, J., Kiebel, S., Phillips, C., Trujillo-Barreto, N., Henson, R., Flandin, G., & Mattout, J. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.09.048 · Cited by 589
The time course of visual word recognition as revealed by linear regression analysis of ERP data
Hauk, O., Davis, M. H., Ford, M., Pulvermüller, F., & Marslen-Wilson, W. D. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.11.048 · Cited by 586
Triggering sleep slow waves by transcranial magnetic stimulation
Massimini, M., Ferrarelli, F., Esser, S. K., Riedner, B. A., Huber, R., Murphy, M., Peterson, M. J., & Tononi, G. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0702495104 · Cited by 489
Lin, F.-H., Witzel, T., Ahlfors, S. P., Stufflebeam, S. M., Belliveau, J. W., & Hämäläinen, M. S. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.11.054 · Cited by 505
Metadata
- Authors
- Fuchs, M., Wagner, M., Köhler, T., & Wischmann, H.-A.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 1999-05
- Volume
- 16
- Issue
- 3
- Pages
- 267-295
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2081465201
- Cited by
- 436
- References
- 28
- FWCI
- 10.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Linear and Nonlinear Current Density Reconstructions. https://app.cochat.ai/papers/10.1097/00004691-199905000-00006
- The paper
- Fuchs, M., Wagner, M., Köhler, T., & Wischmann, H.-A. (1999). Linear and Nonlinear Current Density Reconstructions. Journal of Clinical Neurophysiology. https://doi.org/10.1097/00004691-199905000-00006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.