Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 314

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Multiple sclerosis lesion quantification using fuzzy-connectedness principles

Udupa, J.K., Wei, L., Samarasekera, S., Miki, Y., van Buchem, M.A., Grossman, R.I.·1997·IEEE Transactions on Medical Imaging

Abstract

Multiple sclerosis (MS) is a disease of the white matter. Magnetic resonance imaging (MRI) is proven to be a sensitive method of monitoring the progression of this disease and of its changes due to treatment protocols. Quantification of the severity of the disease through estimation of MS lesion volume via MR imaging is vital for understanding and monitoring the disease and its treatment. This paper presents a novel methodology and a system that can be routinely used for segmenting and estimating the volume of MS lesions via dual-echo fast spin-echo MR imagery. A recently developed concept of fuzzy objects forms the basis of this methodology. An operator indicates a few points in the images by pointing to the white matter, the grey matter, and the cerebro-spinal fluid (CSF). Each of these objects is then detected as a fuzzy connected set. The holes in the union of these objects correspond to potential lesion sites which are utilized to detect each potential lesion as a three-dimensional (3-D) fuzzy connected object. These objects are presented to the operator who indicates acceptance/rejection through the click of a mouse button. The number and volume of accepted lesions is then computed and output. Based on several evaluation studies, we conclude that the methodology is highly reliable and consistent, with a coefficient of variation (due to subjective operator actions) of 0.9% (based on 20 patient studies, three operators, and two trials) for volume and a mean false-negative volume fraction of 1.3%, with a 95% confidence interval of 0%-2.8% (based on ten patient studies).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/42.640750

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 314

Metadata

Authors
Udupa, J. K., Wei, L., Samarasekera, S., Miki, Y., van Buchem, M. A., & Grossman, R. I.
Venue
IEEE Transactions on Medical Imaging
Published
1997
Volume
16
Issue
5
Pages
598-609
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2170750629
Cited by
314
References
1
FWCI
22.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multiple sclerosis lesion quantification using fuzzy-connectedness principles. https://app.cochat.ai/papers/10.1109/42.640750
The paper
Udupa, J. K., Wei, L., Samarasekera, S., Miki, Y., van Buchem, M. A., & Grossman, R. I. (1997). Multiple sclerosis lesion quantification using fuzzy-connectedness principles. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.640750

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.