The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Multiple sclerosis lesion quantification using fuzzy-connectedness principles
Abstract
Multiple sclerosis (MS) is a disease of the white matter. Magnetic resonance imaging (MRI) is proven to be a sensitive method of monitoring the progression of this disease and of its changes due to treatment protocols. Quantification of the severity of the disease through estimation of MS lesion volume via MR imaging is vital for understanding and monitoring the disease and its treatment. This paper presents a novel methodology and a system that can be routinely used for segmenting and estimating the volume of MS lesions via dual-echo fast spin-echo MR imagery. A recently developed concept of fuzzy objects forms the basis of this methodology. An operator indicates a few points in the images by pointing to the white matter, the grey matter, and the cerebro-spinal fluid (CSF). Each of these objects is then detected as a fuzzy connected set. The holes in the union of these objects correspond to potential lesion sites which are utilized to detect each potential lesion as a three-dimensional (3-D) fuzzy connected object. These objects are presented to the operator who indicates acceptance/rejection through the click of a mouse button. The number and volume of accepted lesions is then computed and output. Based on several evaluation studies, we conclude that the methodology is highly reliable and consistent, with a coefficient of variation (due to subjective operator actions) of 0.9% (based on 20 patient studies, three operators, and two trials) for volume and a mean false-negative volume fraction of 1.3%, with a 95% confidence interval of 0%-2.8% (based on ten patient studies).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rating neurologic impairment in multiple sclerosis: An expanded disability status scale (EDSS)
Kurtzke, J. F. (1983) · Neurology · doi:10.1212/wnl.33.11.1444 · Cited by 15,011
On the Statistical Analysis of Dirty Pictures
Besag, J. (1986) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1986.tb01412.x · Cited by 4,191
Paty, D. W., Li, D. K. B., the UBC MS/MRI Study Group, & the IFNB Multiple Sclerosis Study Group (1993) · Neurology · doi:10.1212/wnl.43.4.662 · Cited by 1,967
Adaptive segmentation of MRI data
Wells, W. M., Grimson, W. E. L., Kikinis, R., & Jolesz, F. A. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.511747 · Cited by 1,277
Morphometric analysis of white matter lesions in MR images: method and validation
Zijdenbos, A. P., Dawant, B. M., Margolin, R. A., & Palmer, A. C. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363096 · Cited by 1,265
Girard, M., Duquette, P., & Sibley, W. A. (1993) · Cited by 1,196
Review of MR image segmentation techniques using pattern recognition
Bezdek, J. C., Hall, L. O., & Clarke, L. P. (1993) · Medical Physics · doi:10.1118/1.597000 · Cited by 953
Moment-preserving thresolding: A new approach
Tsai, W.-H. (1985) · Computer Vision, Graphics, and Image Processing · doi:10.1016/0734-189x(85)90133-1 · Cited by 909
Udupa, J. K., & Samarasekera, S. (1996) · Graphical Models and Image Processing · doi:10.1006/gmip.1996.0021 · Cited by 839
Self-citationMRI segmentation: Methods and applications
Clarke, L. P., Velthuizen, R. P., Camacho, M. A., Heine, J. J., Vaidyanathan, M., Hall, L. O., Thatcher, R. W., & Silbiger, M. L. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)00124-l · Cited by 695
Dousset, V, Grossman, R. I., Ramer, K. N., Schnall, M. D., Young, L. H., Gonzalez-Scarano, F., Lavi, E., & Cohen, J. A. (1992) · Radiology · doi:10.1148/radiology.182.2.1732968 · Cited by 690
Self-citationUser-Steered Image Segmentation Paradigms: Live Wire and Live Lane
Falcão, A. X., Udupa, J. K., Samarasekera, S., Sharma, S., Hirsch, B. E., & Lotufo, R. D. A. (1998) · Graphical Models and Image Processing · doi:10.1006/gmip.1998.0475 · Cited by 481
Self-citationNUCLEAR MAGNETIC RESONANCE IMAGING OF THE BRAIN IN MULTIPLE SCLEROSIS
Young, I. R., Hall, A. S., Pallis, C. A., Bydder, G. M., Legg, N. J., & Steiner, R. E. (1981) · The Lancet · doi:10.1016/s0140-6736(81)91273-3 · Cited by 470
Three-Dimensional Segmentation of MR Images of the Head Using Probability and Connectivity
Cline, H. E., Lorensen, W. E., Kikinis, R., & Jolesz, F. (1990) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199011000-00041 · Cited by 359
Segmentation of MR Brain Images into Cerebrospinal Fluid Spaces, White and Gray Matter
Lim, K. O., & Pfefferbaum, A. (1989) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198907000-00006 · Cited by 309
van Walderveen, M. A. A., Barkhof, F., Hommes, O. R., Polman, C. H., Tobi, H., Frequin, S. T. F. M., & Valk, J. (1995) · Neurology · doi:10.1212/wnl.45.9.1684 · Cited by 294
Multiple sclerosis: gadolinium enhancement in MR imaging.
Grossman, R. I., Gonzalez-Scarano, F., Atlas, S. W., Galetta, S., & Silberberg, D. H. (1986) · Radiology · doi:10.1148/radiology.161.3.3786722 · Cited by 289
Self-citationKohn, M. I., Tanna, N. K., Herman, G. T., Resnick, S. M., Mozley, P. D., Gur, R. E., Alavi, A., Zimmerman, R. A., & Gur, R. C. (1991) · Radiology · doi:10.1148/radiology.178.1.1984289 · Cited by 273
Segmentation of multiple sclerosis lesions in intensity corrected multispectral MRI
Johnston, B., Atkins, M. S., Mackiewich, B., & Anderson, M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.491417 · Cited by 260
Method for Quantification of Brain, Ventricular, and Subarachnoid CSF Volumes from MR Images
DeCarli, C., Maisog, J., Murphy, D. G. M., Teichberg, D., Rapoport, S. I., & Horwitz, B. (1992) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199203000-00018 · Cited by 259
Routine quantitative analysis of brain and cerebrospinal fluid spaces with MR imaging
Kikinis, R., Shenton, M. E., Gerig, G., Martin, J., Anderson, M., Metcalf, D., Guttmann, C. R. G., McCarley, R. W., Jolesz, F. A., Lorensen, W., et al. (1992) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880020603 · Cited by 237
Alzheimer disease: measuring loss of cerebral gray matter with MR imaging.
Rusinek, H., de Leon, M. J., George, A. E., Stylopoulos, L. A., Chandra, R., Smith, G., Rand, T., Mourino, M., & Kowalski, H. (1991) · Radiology · doi:10.1148/radiology.178.1.1984287 · Cited by 218
Model-based 3-D segmentation of multiple sclerosis lesions in magnetic resonance brain images
Kamber, M., Shinghal, R., Collins, D. L., Francis, G. S., & Evans, A. C. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.414608 · Cited by 211
Nuclear magnetic resonance imaging in multiple sclerosis
Lukes, S. A., Crooks, L. E., Aminoff, M. J., Kaufman, L., Panitch, H. S., Mills, C., & Norman, D. (1983) · Annals of Neurology · doi:10.1002/ana.410130603 · Cited by 200
Quantitative assessment of MRI lesion load in monitoring the evolution of multiple sclerosis
Filippi, M., Horsfield, M. A., Tofts, P. S., Barkhof, F., Thompson, A. J., & Miller, D. H. (1995) · Brain · doi:10.1093/brain/118.6.1601 · Cited by 178
Retrospective correction of intensity inhomogeneities in MRI
Meyer, C. R., Bland, P. H., & Pipe, J. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.370400 · Cited by 176
Udupa, J. K., Odhner, D., Samarasekera, S., Gonçalves, R. J., Iyer, K., Venugopal, K. P., & Furuie, S. S. (1994) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.174042 · Cited by 131
Self-citationIntra- and inter-observer agreement of brain MRI lesion volume measurements in multiple sclerosis
Filippi, M., Horsfield, M. A., Bressi, S., et al. (1995) · Brain · doi:10.1093/brain/118.6.1593 · Cited by 124
Volume measurement of multiple sclerosis lesions with magnetic resonance images
Wicks, D., Tofts, P. S., Miller, D. H., du Boulay, G. H., Feinstein, A., Sacares, R. P., Harvey, I., Brenner, R., & McDonald, W. I. (1992) · Neuroradiology · doi:10.1007/bf00598953 · Cited by 105
Frank, J. A., Stone, L. A., Smith, M. E., Albert, P. S., Maloni, H. W., & McFarland, H. F. (1994) · Annals of Neurology · doi:10.1002/ana.410360719 · Cited by 92
Magnetic resonance imaging in the evaluation of clinical trials in multiple sclerosis
Paty, D. W., Li, D. K. B., Oger, J. J.-F., Kastrukoff, L. F., Koopmans, R. A., Tanton, E., & Zhao, G. J. (1994) · Annals of Neurology · doi:10.1002/ana.410360721 · Cited by 90
Model-based segmentation of individual brain structures from MRI data
Collins, D. L., Peters, T. M., Dai, W., & Evans, A. C. (1992) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.131063 · Cited by 86
Mitchell, J. R., Karlik, S. J., Lee, D. H., & Fenster, A. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040218 · Cited by 84
Accuracy and Reproducibility in Volumetric Analysis of Multiple Sclerosis Lesions
Jackson, E. F., Narayana, P. A., Wolinsky, J. S., & Doyle, T. J. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199303000-00007 · Cited by 79
Uhlenbrock, D., & Sehlen, S. (1989) · Neuroradiology · doi:10.1007/bf00344344 · Cited by 77
The variability of manual and computer assisted quantification of multiple sclerosis lesion volumes
Mitchell, J. R., Karlik, S. J., Lee, D. H., Eliasziw, M., Rice, G. P., & Fenster, A. (1996) · Medical Physics · doi:10.1118/1.597685 · Cited by 72
MR imaging of multiple sclerosis: comparison with clinical and CT examinations in 74 patients
Jj, S., Siddharthan, R., Tobias, J. K., Sheremata, W. A., Soila, K., & Viamonte, M. I. (1985) · American Journal of Roentgenology · doi:10.2214/ajr.145.5.957 · Cited by 65
Filippi, M., Rovaris, M., Campi, A., et al. (2009) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.1996.tb00166.x · Cited by 32
Gonzalez, C. F., Swirsky-Sacchetti, T., Mitchell, D., LUBLIN, F. D., Knobler, R. L., & Ehrlich, S. M. (1994) · Journal of Neuroimaging · doi:10.1111/jon199444188 · Cited by 23
Cited by
New variants of a method of MRI scale standardization
Nyul, L. G., Udupa, J. K., & Zhang, X. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.836373 · Cited by 956
Self-citationMiller, D. H. (2002) · Brain · doi:10.1093/brain/awf177 · Cited by 631
On standardizing the MR image intensity scale
Ny�l, L. G., & Udupa, J. K. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199912)42:6<1072::aid-mrm11>3.0.co;2-m · Cited by 583
Self-citationThe role of magnetic resonance techniques in understanding and managing multiple sclerosis
Miller, D. (1998) · Brain · doi:10.1093/brain/121.1.3 · Cited by 556
Automated segmentation of multiple sclerosis lesions by model outlier detection
Van Leemput, K., Maes, F., Vandermeulen, D., Colchester, A., & Suetens, P. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.938237 · Cited by 489
Metadata
- Authors
- Udupa, J. K., Wei, L., Samarasekera, S., Miki, Y., van Buchem, M. A., & Grossman, R. I.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1997
- Volume
- 16
- Issue
- 5
- Pages
- 598-609
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2170750629
- Cited by
- 314
- References
- 39
- FWCI
- 22.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.