The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Speckle reduction and contrast enhancement of echocardiograms via multiscale nonlinear processing
Open accessAbstract
This paper presents an algorithm for speckle reduction and contrast enhancement of echocardiographic images. Within a framework of multiscale wavelet analysis, we apply wavelet shrinkage techniques to eliminate noise while preserving the sharpness of salient features. In addition, nonlinear processing of feature energy is carried out to enhance contrast within local structures and along object boundaries. We show that the algorithm is capable of not only reducing speckle, but also enhancing features of diagnostic importance, such as myocardial walls in two-dimensional echocardiograms obtained from the parasternal short-axis view. Shrinkage of wavelet coefficients via soft thresholding within finer levels of scale is carried out on coefficients of logarithmically transformed echocardiograms. Enhancement of echocardiographic features is accomplished via nonlinear stretching followed by hard thresholding of wavelet coefficients within selected (midrange) spatial-frequency levels of analysis. We formulate the denoising and enhancement problem, introduce a class of dyadic wavelets, and describe our implementation of a dyadic wavelet transform. Our approach for speckle reduction and contrast enhancement was shown to be less affected by pseudo-Gibbs phenomena. We show experimentally that this technique produced superior results both qualitatively and quantitatively when compared to results obtained from existing denoising methods alone. A study using a database of clinical echocardiographic images suggests that such denoising and enhancement may improve the overall consistency of expert observers to manually defined borders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
De-noising by soft-thresholding
Donoho, D. L. (1995) · IEEE Transactions on Information Theory · doi:10.1109/18.382009 · Cited by 9,619
Orthonormal bases of compactly supported wavelets
Daubechies, I. (1988) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.3160410705 · Cited by 8,190
Fundamentals of digital image processing
Jain, A. K. (1988) · Cited by 7,111
Characterization of signals from multiscale edges
Mallat, S., & Zhong, S. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.142909 · Cited by 3,200
Some fundamental properties of speckle*
Goodman, J. W. (1976) · Journal of the Optical Society of America · doi:10.1364/josa.66.001145 · Cited by 2,125
Translation-Invariant De-Noising
Coifman, R. R., & Donoho, D. L. (1995) · Lecture Notes in Statistics · doi:10.1007/978-1-4612-2544-7_9 · Cited by 1,914
Mammographic feature enhancement by multiscale analysis
Laine, A. F., Schuler, S., Fan, J., & Huda, W. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363095 · Cited by 357
Self-citationA multiple active contour model for cardiac boundary detection on echocardiographic sequences
Chalana, V., Linker, D. T., Haynor, D. R., & Kim, Y. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.500138 · Cited by 305
Acoustic speckle: Theory and experimental analysis
Abbott, J. (1979) · Ultrasonic Imaging · doi:10.1016/0161-7346(79)90024-5 · Cited by 269
Acoustic Speckle: Theory and Experimental Analysis
Abbott, J. G., & Thurstone, F. L. (1979) · Ultrasonic Imaging · doi:10.1177/016173467900100402 · Cited by 250
Cited by
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157
Nonlocal means-based speckle filtering for ultrasound images
Coupe, P., Hellier, P., Kervrann, C., & Barillot, C. (2009) · IEEE Transactions on Image Processing · doi:10.1109/tip.2009.2024064 · Cited by 617
Novel Bayesian multiscale method for speckle removal in medical ultrasound images
Achim, A., Bezerianos, A., & Tsakalides, P. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.938245 · Cited by 592
SAR speckle reduction using wavelet denoising and Markov random field modeling
Xie, H., Pierce, L. E., & Ulaby, F. T. (2002) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2002.802473 · Cited by 416
Abd-Elmoniem, K. Z., Youssef, A.-B. M., & Kadah, Y. M. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.1028423 · Cited by 403
Oriented Speckle Reducing Anisotropic Diffusion
Krissian, K., Westin, C.-F., Kikinis, R., & Vosburgh, K. G. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.891803 · Cited by 377
An Experiment-Based Review of Low-Light Image Enhancement Methods
Wang, W., Wu, X., Yuan, X., & Gao, Z. (2020) · IEEE Access · doi:10.1109/access.2020.2992749 · Cited by 364
Comparative evaluation of despeckle filtering in ultrasound imaging of the carotid artery
Loizou, C. P., Pattichis, C. S., Christodoulou, C. I., Istepanian, R. S. H., Pantziaris, M., & Nicolaides, A. (2005) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1561621 · Cited by 323
Metadata
- Authors
- Zong, X., Laine, A. F., & Geiser, E. A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1998
- Volume
- 17
- Issue
- 4
- Pages
- 532-540
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2150737937
- Cited by
- 337
- References
- 14
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.