The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Homodyne detection in magnetic resonance imaging
Abstract
Magnetic detection of complex images in magnetic resonance imaging (MRI) is immune to the effects of incidental phase variations, although in some applications information is lost or images are degraded. It is suggested that synchronous detection or demodulation can be used in MRI systems in place of magnitude detection to provide complete suppression of undesired quadrature components, to preserve polarity and phase information, and to eliminate the biases and reduction in signal-to-noise ratio (SNR) and contrast in low SNR images. The incidental phase variations in an image are removed through the use of a homodyne demodulation reference, which is derived from the image or the object itself. Synchronous homodyne detection has been applied to the detection of low SNR images, the reconstruction of partial k-space images, the simultaneous detection of water and lipid signals in quadrature, and the preservation of polarity in inversion-recovery images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Fourier Transform and Its Applications
Bracewell, R., & Kahn, P. B. (1966) · American Journal of Physics · doi:10.1119/1.1973431 · Cited by 5,737
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
An Introduction to Statistical Communication Theory
Middleton, D. (2009) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470544112.part1 · Cited by 1,127
Statistical Properties of a Sine Wave Plus Random Noise
Rice, S. O. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb01334.x · Cited by 909
An introduction to statistical communication theory
Siebert, W. M. (1961) · Journal of the Franklin Institute · doi:10.1016/0016-0032(61)90153-3 · Cited by 703
Ziemer, R. E., & Tranter, W. H. (1976) · Cited by 304
Halving MR imaging time by conjugation: demonstration at 3.5 kG.
Feinberg, D. A., Hale, J. D., Watts, J. C., Kaufman, L., & Mark, A. (1986) · Radiology · doi:10.1148/radiology.161.2.3763926 · Cited by 259
(1986) · Ophthalmology · doi:10.1016/s0161-6420(86)33832-6 · Cited by 184
Research works printed but not linked: 24
- 10.1002/mrm.1910140107 · doi:10.1002/mrm.1910140107
- 10.1002/mrm.1910030104 · doi:10.1002/mrm.1910030104
- 10.1002/mrm.1910110202 · doi:10.1002/mrm.1910110202
- margosian, 1986, Faster MR imaging: Imaging with half the data, Health Care Instrum, 1, 195
- 10.1002/mrm.1910080112 · doi:10.1002/mrm.1910080112
- 10.1109/IEMBS.1989.95888 · doi:10.1109/iembs.1989.95888
- 10.1016/0730-725X(87)90402-4 · doi:10.1016/0730-725x(87)90402-4
- oh, 1987, Faster magnetic resonance imaging by use of 3-quarter matrix data, Proc 7th Annu Meet Soc Magn Res Med, 455
- 10.1016/0730-725X(88)90444-4 · doi:10.1016/0730-725x(88)90444-4
- 10.1097/00004728-198805010-00022 · doi:10.1097/00004728-198805010-00022
- 10.1002/mrm.1910020110 · doi:10.1002/mrm.1910020110
- macovski, 1988, Applications of homodyne detection using separate reference acquisition, Proc 7th Annu Meet Soc Magn Res Med, 983
- 10.1002/mrm.1910040506 · doi:10.1002/mrm.1910040506
- macovski, 1988, Homodyne detection for improved SNR and partiak �-space reconstructions, Proc 7th Annu Meet Soc Magn Res Med, 815
- 10.1109/TMI.1984.4307681 · doi:10.1109/tmi.1984.4307681
- taub, 1986, Principles of Communication Systems
- meyer, 1987, Square spiral fast imaging: Interleaving and off-resonance effects, ?roc 6th Ann Meet Soc Mag Res Med, 230
- 10.1118/1.596304 · doi:10.1118/1.596304
- 10.1118/1.595732 · doi:10.1118/1.595732
- 10.1002/mrm.1910100207 · doi:10.1002/mrm.1910100207
- glasford, 1955, Fundamentals of Television Engineering
- paltiel, 1985, Separate water and lipid images obtained by a single scan, Proc 4th Annu Meet Soc Magn Res Med, 172
- patrick, 1985, Water/fat separation and chemical shift artifact correction using a single scan, Proc 4th Annu Meet Soc Magn Res Med, 174
- 10.1016/0730-725X(86)90921-5 · doi:10.1016/0730-725x(86)90921-5
Cited by
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Schweser, F., Deistung, A., Lehr, B. W., & Reichenbach, J. R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.070 · Cited by 710
Reeder, S. B., Pineda, A. R., Wen, Z., Shimakawa, A., Yu, H., Brittain, J. H., Gold, G. E., Beaulieu, C. H., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20624 · Cited by 706
Wavelet-based Rician noise removal for magnetic resonance imaging
Nowak, R. D. (1999) · IEEE Transactions on Image Processing · doi:10.1109/83.791966 · Cited by 620
Dixon techniques for water and fat imaging
Ma, J. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21492 · Cited by 610
Metadata
- Authors
- Noll, D. C., Nishimura, D. G., & Macovski, A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1991-06
- Volume
- 10
- Issue
- 2
- Pages
- 154-163
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2106263593
- Cited by
- 514
- References
- 8
- FWCI
- 3.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.