The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Adaptive fuzzy segmentation of magnetic resonance images
Abstract
An algorithm is presented for the fuzzy segmentation of two-dimensional (2-D) and three-dimensional (3-D) multispectral magnetic resonance (MR) images that have been corrupted by intensity inhomogeneities, also known as shading artifacts. The algorithm is an extension of the 2-D adaptive fuzzy C-means algorithm (2-D AFCM) presented in previous work by the authors. This algorithm models the intensity inhomogeneities as a gain field that causes image intensities to smoothly and slowly vary through the image space. It iteratively adapts to the intensity inhomogeneities and is completely automated. In this paper, we fully generalize 2-D AFCM to three-dimensional (3-D) multispectral images. Because of the potential size of 3-D image data, we also describe a new faster multigrid-based algorithm for its implementation. We show, using simulated MR data, that 3-D AFCM yields lower error rates than both the standard fuzzy C-means (FCM) algorithm and two other competing methods, when segmenting corrupted images. Its efficacy is further demonstrated using real 3-D scalar and multispectral MR brain images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Density Estimation for Statistics and Data Analysis
Silverman, B. W. (2018) · Routledge eBooks · doi:10.1201/9781315140919 · Cited by 15,796
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Cited by 15,411
A Fuzzy Relative of the ISODATA Process and Its Use in Detecting Compact Well-Separated Clusters
Dunn, J. C. (1973) · Journal of Cybernetics · doi:10.1080/01969727308546046 · Cited by 5,049
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731 · cited 3×
“In addition, error measures were also computed for a segmentation obtained by first applying the inhomogeneity correction software [12] obtained from the Montreal Neurological Institute, then applying FCM.”
BackgroundMethodFuzzy clustering with a fuzzy covariance matrix
Gustafson, D., & Kessel, W. (1978) · 1978 IEEE Conference on Decision and Control including the 17th Symposium on Adaptive Processes · doi:10.1109/cdc.1978.268028 · Cited by 1,978
Briggs, W. L. (1987) · Cited by 1,868
Adaptive segmentation of MRI data
Wells, W. M., Grimson, W. E. L., Kikinis, R., & Jolesz, F. A. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.511747 · Cited by 1,277
Bottomley, P. A., Foster, T. H., Argersinger, R. E., & Pfeifer, L. M. (1984) · Medical Physics · doi:10.1118/1.595535 · Cited by 1,192
A Convergence Theorem for the Fuzzy ISODATA Clustering Algorithms
Bezdek, J. C. (1980) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1980.4766964 · Cited by 980
Review of MR image segmentation techniques using pattern recognition
Bezdek, J. C., Hall, L. O., & Clarke, L. P. (1993) · Medical Physics · doi:10.1118/1.597000 · Cited by 953
B-spline signal processing. I. Theory
Unser, M., Aldroubi, A., & Eden, M. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193220 · Cited by 940
Udupa, J. K., & Samarasekera, S. (1996) · Graphical Models and Image Processing · doi:10.1006/gmip.1996.0021 · Cited by 839
Statistical approach to segmentation of single-channel cerebral MR images
Rajapakse, J. C., Giedd, J. N., & Rapoport, J. L. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563663 · Cited by 678
B-SPLINE SIGNAL PROCESSING: PART I-THEORY
Unser, M. A., Aldroubi, A., & Eden, M. (1993) · Cited by 626
An adaptive clustering algorithm for image segmentation
Pappas, T. N. (1992) · IEEE Transactions on Signal Processing · doi:10.1109/78.127962 · Cited by 589
Hall, L. O., Bensaid, A. M., Clarke, L. P., Velthuizen, R. P., Silbiger, M. S., & Bezdek, J. C. (1992) · IEEE Transactions on Neural Networks · doi:10.1109/72.159057 · Cited by 580
Pham, D. L., & Prince, J. L. (1999) · Pattern Recognition Letters · doi:10.1016/s0167-8655(98)00121-4 · Cited by 472
Self-citationEstimating the bias field of MR images
Guillemaud, R., & Brady, M. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.585758 · Cited by 329
Segmentation of MR Brain Images into Cerebrospinal Fluid Spaces, White and Gray Matter
Lim, K. O., & Pfefferbaum, A. (1989) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198907000-00006 · Cited by 309
An Image-Processing System for Qualitative and Quantitative Volumetric Analysis of Brain Images
Goldszal, A. F., Davatzikos, C., Pham, D. L., Yan, M. X. H., Bryan, R. N., & Resnick, S. M. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199809000-00030 · Cited by 295
Self-citationCorrection of intensity variations in MR images for computer-aided tissue classification
Dawant, B. M., Zijdenbos, A. P., & Margolin, R. A. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.251128 · Cited by 291
Sources of intensity nonuniformity in spin echo images at 1.5 T
Simmons, A., Tofts, P. S., Barker, G. J., & Arridge, S. R. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320117 · Cited by 277
Segmentation of multiple sclerosis lesions in intensity corrected multispectral MRI
Johnston, B., Atkins, M. S., Mackiewich, B., & Anderson, M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.491417 · Cited by 260
Density Estimation for Statistics and Data Analysis.
Kemp, C. D., & Silverman, B. W. (1987) · The Statistician · doi:10.2307/2348849 · Cited by 252
Optimized homomorphic unsharp masking for MR grayscale inhomogeneity correction
Brinkmann, B. H., Manduca, A., & Robb, R. A. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.700729 · Cited by 213
Retrospective correction of intensity inhomogeneities in MRI
Meyer, C. R., Bland, P. H., & Pipe, J. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.370400 · Cited by 176
Brandt, M. E., Bohant, T. P., Kramer, L. A., & Fletcher, J. M. (1994) · Computerized Medical Imaging and Graphics · doi:10.1016/0895-6111(94)90058-2 · Cited by 139
Liang, Z., Jaszczak, R. J., & Coleman, R. E. (1992) · IEEE Transactions on Nuclear Science · doi:10.1109/23.159772 · Cited by 136
Image non-uniformity in magnetic resonance imaging: its magnitude and methods for its correction
Condon, B. R., Patterson, J. C., Wyper, D., Jenkins, A., & Hadley, D. M. (1987) · British Journal of Radiology · doi:10.1259/0007-1285-60-709-83 · Cited by 120
Optimal space-varying regularization in iterative image restoration
Reeves, S. J. (1994) · IEEE Transactions on Image Processing · doi:10.1109/83.287028 · Cited by 50
Post‐acquisition correction of MR inhomogeneities
Lee, S., & Vannier, M. W. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360215 · Cited by 42
Cited by
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507
Brain development in children and adolescents: Insights from anatomical magnetic resonance imaging
Lenroot, R. K., & Giedd, J. N. (2006) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2006.06.001 · Cited by 1,863
A modified fuzzy c-means algorithm for bias field estimation and segmentation of MRI data
Ahmed, M. N., Yamany, S. M., Mohamed, N., Farag, A. A., & Moriarty, T. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.996338 · Cited by 1,792
Fuzzy c-means clustering with spatial information for image segmentation
Chuang, K.-S., Tzeng, H.-L., Chen, S., Wu, J., & Chen, T.-J. (2006) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2005.10.001 · Cited by 1,323
HAMMER: hierarchical attribute matching mechanism for elastic registration
Shen, D., & Davatzikos, C. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.803111 · Cited by 1,083
Metadata
- Authors
- Pham, D. L., & Prince, J. L.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1999
- Volume
- 18
- Issue
- 9
- Pages
- 737-752
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2108707886
- Cited by
- 805
- References
- 31
- FWCI
- 18.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.