The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Automated model-based bias field correction of MR images of the brain
Abstract
We propose a model-based method for fully automated bias field correction of MR brain images. The MR signal is modeled as a realization of a random process with a parametric probability distribution that is corrupted by a smooth polynomial inhomogeneity or bias field. The method we propose applies an iterative expectation-maximization (EM) strategy that interleaves pixel classification with estimation of class distribution and bias field parameters, improving the likelihood of the model parameters at each iteration. The algorithm, which can handle multichannel data and slice-by-slice constant intensity offsets, is initialized with information from a digital brain atlas about the a priori expected location of tissue classes. This allows full automation of the method without need for user interaction, yielding more objective and reproducible results. We have validated the bias correction algorithm on simulated data and we illustrate its performance on various MR images with important field inhomogeneities. We also relate the proposed algorithm to other bias correction algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
(1975) · CERN Document Server (European Organization for Nuclear Research) · Cited by 5,958
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Self-citationMaximum likelihood estimation from incomplete data via the EM algorithm
Dempster, A. P. (1977) · Journal of the Royal Statistical Society Series A (Statistics in Society) · Cited by 4,543
Maximum Likelihood from Incomplete Data via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1976) · Cited by 4,517
On the Convergence Properties of the EM Algorithm
Wu, C. F. J. (1983) · The Annals of Statistics · doi:10.1214/aos/1176346060 · Cited by 3,269
The rician distribution of noisy mri data
Gudbjartsson, H., & Patz, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340618 · Cited by 2,494
Design and construction of a realistic digital brain phantom
Collins, D. L., Zijdenbos, A. P., Kollokian, V., Sled, J. G., Kabani, N. J., Holmes, C. J., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712135 · Cited by 1,822
3D statistical neuroanatomical models from 305 MRI volumes
Evans, A. C., Collins, D. L., Mills, S. R., Brown, E. D., Kelly, R. L., & Peters, T. M. (2005) · 1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference · doi:10.1109/nssmic.1993.373602 · Cited by 1,487
Sibson, R., & Hartigan, J. A. (1976) · Applied Statistics · doi:10.2307/2346526 · Cited by 1,435
Adaptive segmentation of MRI data
Wells, W. M., Grimson, W. E. L., Kikinis, R., & Jolesz, F. A. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.511747 · Cited by 1,277
Jähne, B. (1993) · Springer eBooks · doi:10.1007/978-3-662-21817-4 · Cited by 1,139
Automated model-based tissue classification of MR images of the brain
Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811270 · Cited by 1,024
Self-citationMulti-modality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1996) · Proceedings of the Workshop on Mathematical Methods in Biomedical Image Analysis · doi:10.1109/mmbia.1996.534053 · Cited by 795
Self-citationMarkov Random Field Segmentation of Brain MR Images
Held, K., Kops, E. R., Krause, B. J., Wells, W. M., III, Kikinis, R., & Müller-Gärtner, H.-W. (1997) · Cited by 484
Statistical Parametric Mapping
(2007) · Elsevier eBooks · doi:10.1016/b978-0-12-372560-8.x5000-1 · Cited by 387
Markov random field segmentation of brain MR images
Held, K., Kops, E. R., Krause, B. J., Wells, W. M., Kikinis, R., & Muller-Gartner, H.-W. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.650883 · Cited by 381
Estimating the bias field of MR images
Guillemaud, R., & Brady, M. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.585758 · Cited by 329
Correction of intensity variations in MR images for computer-aided tissue classification
Dawant, B. M., Zijdenbos, A. P., & Margolin, R. A. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.251128 · Cited by 291
An extensible MRI simulator for post-processing evaluation
Kwan, R. K. S., Evans, A. C., & Pike, G. B. (1996) · Lecture Notes in Computer Science · doi:10.1007/bfb0046947 · Cited by 284
Sources of intensity nonuniformity in spin echo images at 1.5 T
Simmons, A., Tofts, P. S., Barker, G. J., & Arridge, S. R. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320117 · Cited by 277
Polynomial modeling and reduction of RF body coil spatial inhomogeneity in MRI
Tincher, M., Meyer, C. R., Gupta, R., et al. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.232267 · Cited by 136
Non-rigid multimodal image registration using mutual information
Gaens, T., Maes, F., Vandermeulen, D., & Suetens, P. (1998) · Lecture notes in computer science · doi:10.1007/bfb0056299 · Cited by 123
Self-citationSurface coil MR imaging of the human brain with an analytic reception profile correction
Moyher, S. E., Vigneron, D. B., & Nelson, S. J. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050204 · Cited by 95
Compensation of spatial inhomogeneity in MRI based on a parametric bias estimate
Brechbühler, C., Gerig, G., & Székely, G. J. (1996) · Lecture notes in computer science · doi:10.1007/bfb0046948 · Cited by 60
Understanding intensity non-uniformity in MRI
Sled, J. G., & Pike, G. B. (1998) · Lecture notes in computer science · doi:10.1007/bfb0056247 · Cited by 49
A comparison of retrospective intensity non-uniformity correction methods for MRI
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1997) · Lecture notes in computer science · doi:10.1007/3-540-63046-5_43 · Cited by 48
Bias field correction of breast MR images
Gilles, S., Brady, M., Declerck, J. M., et al. (1996) · Lecture notes in computer science · doi:10.1007/bfb0046950 · Cited by 38
Cited by
Yushkevich, P. A., Piven, J., Hazlett, H. C., Smith, R. G., Ho, S., Gee, J. C., & Gerig, G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.015 · Cited by 8,868
Voxel-Based Morphometry—The Methods
Ashburner, J., & Friston, K. J. (2000) · NeuroImage · doi:10.1006/nimg.2000.0582 · Cited by 8,676
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507
The multimodal brain tumor image segmentation benchmark (BRATS)
Menze, B. H., Jakab, A., Bauer, S., Kalpathy-Cramer, J., Farahani, K., Kirby, J., Burren, Y., Porz, N., Slotboom, J., Wiest, R., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2377694 · Cited by 6,781
Self-citationMutual-information-based registration of medical images: a survey
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815867 · Cited by 2,890
Metadata
- Authors
- Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1999
- Volume
- 18
- Issue
- 10
- Pages
- 885-896
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2161591846
- Cited by
- 583
- References
- 29
- FWCI
- 14.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.