The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Survey: interpolation methods in medical image processing
Abstract
Image interpolation techniques often are required in medical imaging for image generation (e.g., discrete back projection for inverse Radon transform) and processing such as compression or resampling. Since the ideal interpolation function spatially is unlimited, several interpolation kernels of finite size have been introduced. This paper compares 1) truncated and windowed sinc; 2) nearest neighbor; 3) linear; 4) quadratic; 5) cubic B-spline; 6) cubic; g) Lagrange; and 7) Gaussian interpolation and approximation techniques with kernel sizes from 1 x 1 up to 8 x 8. The comparison is done by: 1) spatial and Fourier analyses; 2) computational complexity as well as runtime evaluations; and 3) qualitative and quantitative interpolation error determinations for particular interpolation tasks which were taken from common situations in medical image processing. For local and Fourier analyses, a standardized notation is introduced and fundamental properties of interpolators are derived. Successful methods should be direct current (DC)-constant and interpolators rather than DC-inconstant or approximators. Each method's parameters are tuned with respect to those properties. This results in three novel kernels, which are introduced in this paper and proven to be within the best choices for medical image interpolation: the 6 x 6 Blackman-Harris windowed sinc interpolator, and the C2-continuous cubic kernels with N = 6 and N = 8 supporting points. For quantitative error evaluations, a set of 50 direct digital X rays was used. They have been selected arbitrarily from clinical routine. In general, large kernel sizes were found to be superior to small interpolation masks. Except for truncated sinc interpolators, all kernels with N = 6 or larger sizes perform significantly better than N = 2 or N = 3 point methods (p << 0.005). However, the differences within the group of large-sized kernels were not significant. Summarizing the results, the cubic 6 x 6 interpolator with continuous second derivatives, as defined in (24), can be recommended for most common interpolation tasks. It appears to be the fastest six-point kernel to implement computationally. It provides eminent local and Fourier properties, is easy to implement, and has only small errors. The same characteristics apply to B-spline interpolation, but the 6 x 6 cubic avoids the intrinsic border effects produced by the B-spline technique. However, the goal of this study was not to determine an overall best method, but to present a comprehensive catalogue of methods in a uniform terminology, to define general properties and requirements of local techniques, and to enable the reader to select that method which is optimal for his specific application in medical imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the use of windows for harmonic analysis with the discrete Fourier transform
Harris, F. J. (1978) · Proceedings of the IEEE · doi:10.1109/proc.1978.10837 · Cited by 7,326 · cited 1×
“A systematic approach on the use of windows for harmonic analysis with the discrete Fourier transform is given by Harris who declared the Kaiser–Bessel and Blackman–Harris windows to be the top performers [27].”
MethodCubic convolution interpolation for digital image processing
Keys, R. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163711 · Cited by 3,255
Buckingham, R. A. (1966) · Cited by 2,899
Cubic splines for image interpolation and digital filtering
Hou, H., & Andrews, H. (1978) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1978.1163154 · Cited by 1,270
B-spline signal processing. I. Theory
Unser, M., Aldroubi, A., & Eden, M. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193220 · Cited by 940
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Comparison of Interpolating Methods for Image Resampling
Parker, J. A., Kenyon, R. V., & Troxel, D. E. (1983) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1983.4307610 · Cited by 829
B-spline signal processing. II. Efficiency design and applications
Unser, M., Aldroubi, A., & Eden, M. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193221 · Cited by 641
B-SPLINE SIGNAL PROCESSING: PART I-THEORY
Unser, M. A., Aldroubi, A., & Eden, M. (1993) · Cited by 626
A digital signal processing approach to interpolation
Schafer, R. W., & Rabiner, L. R. (1973) · Proceedings of the IEEE · doi:10.1109/proc.1973.9150 · Cited by 554
A Bayesian approach to image expansion for improved definition
Schultz, R. R., & Stevenson, R. L. (1994) · IEEE Transactions on Image Processing · doi:10.1109/83.287017 · Cited by 535
B-SPLINE SIGNAL PROCESSING: PART II-EFFICIENT DESIGN AND APPLICATIONS
Unser, M. A., Aldroubi, A., & Eden, M. (1993) · Cited by 463
Reconstruction filters in computer-graphics
Mitchell, D. P., & Netravali, A. N. (1988) · ACM SIGGRAPH Computer Graphics · doi:10.1145/378456.378514 · Cited by 383
Image reconstruction by parametric cubic convolution
Park, S. K., & Schowengerdt, R. A. (1983) · Computer Vision Graphics and Image Processing · doi:10.1016/0734-189x(83)90026-9 · Cited by 371
Quadratic interpolation for image resampling
Dodgson, N. A. (1997) · IEEE Transactions on Image Processing · doi:10.1109/83.623195 · Cited by 212
Bildverarbeitung für die Medizin
Lehmann, T., Oberschelp, W., Pelikan, E., & Repges, R. (1997) · Springer eBooks · doi:10.1007/978-3-642-60487-4 · Cited by 207
Self-citationRecursive regularization filters: design, properties, and applications
Unser, M., Aldroubi, A., & Eden, M. (1991) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.75514 · Cited by 193
An objective comparison of 3-D image interpolation methods
Grevera, G. J., & Udupa, J. K. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730408 · Cited by 180
Computer implementation of image reconstruction formulas
Rowland, S. W. (1979) · Topics in applied physics · doi:10.1007/3-540-09417-2_2 · Cited by 150
Unser, M. A., Aldroubi, A., & Eden, M. (1992) · IEEE Transactions on Information Theory · doi:10.1109/18.108253 · Cited by 129
Analysis of Interpolation Effects in the Reslicing of Functional MR Images
Ostuni, J. L., Santha, A. K. S., Mattay, V. S., Weinberger, D. R., Levin, R. L., & Frank, J. A. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199709000-00029 · Cited by 62
A new approach to the interpolation of sampled data
Appledorn, C. R. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.500145 · Cited by 45
Cited by
Image registration methods: a survey
Zitová, B., & Flusser, J. (2003) · Image and Vision Computing · doi:10.1016/s0262-8856(03)00137-9 · Cited by 6,423
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
An edge-guided image interpolation algorithm via directional filtering and data fusion
Zhang, L., & Wu, X. (2006) · IEEE Transactions on Image Processing · doi:10.1109/tip.2006.877407 · Cited by 1,020
A chronology of interpolation: from ancient astronomy to modern signal and image processing
Meijering, E. (2002) · Proceedings of the IEEE · doi:10.1109/5.993400 · Cited by 662
Channel estimation for wireless ofdm systems
Ozdemir, M., & Arslan, H. (2007) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2007.382406 · Cited by 641
Metadata
- Authors
- Lehmann, T. M., Gonner, C., & Spitzer, K.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1999
- Volume
- 18
- Issue
- 11
- Pages
- 1049-1075
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2113524221
- Cited by
- 1,340
- References
- 22
- FWCI
- 15.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.