The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Survey: interpolation methods in medical image processing
Abstract
Image interpolation techniques often are required in medical imaging for image generation (e.g., discrete back projection for inverse Radon transform) and processing such as compression or resampling. Since the ideal interpolation function spatially is unlimited, several interpolation kernels of finite size have been introduced. This paper compares 1) truncated and windowed sinc; 2) nearest neighbor; 3) linear; 4) quadratic; 5) cubic B-spline; 6) cubic; g) Lagrange; and 7) Gaussian interpolation and approximation techniques with kernel sizes from 1 x 1 up to 8 x 8. The comparison is done by: 1) spatial and Fourier analyses; 2) computational complexity as well as runtime evaluations; and 3) qualitative and quantitative interpolation error determinations for particular interpolation tasks which were taken from common situations in medical image processing. For local and Fourier analyses, a standardized notation is introduced and fundamental properties of interpolators are derived. Successful methods should be direct current (DC)-constant and interpolators rather than DC-inconstant or approximators. Each method's parameters are tuned with respect to those properties. This results in three novel kernels, which are introduced in this paper and proven to be within the best choices for medical image interpolation: the 6 x 6 Blackman-Harris windowed sinc interpolator, and the C2-continuous cubic kernels with N = 6 and N = 8 supporting points. For quantitative error evaluations, a set of 50 direct digital X rays was used. They have been selected arbitrarily from clinical routine. In general, large kernel sizes were found to be superior to small interpolation masks. Except for truncated sinc interpolators, all kernels with N = 6 or larger sizes perform significantly better than N = 2 or N = 3 point methods (p << 0.005). However, the differences within the group of large-sized kernels were not significant. Summarizing the results, the cubic 6 x 6 interpolator with continuous second derivatives, as defined in (24), can be recommended for most common interpolation tasks. It appears to be the fastest six-point kernel to implement computationally. It provides eminent local and Fourier properties, is easy to implement, and has only small errors. The same characteristics apply to B-spline interpolation, but the 6 x 6 cubic avoids the intrinsic border effects produced by the B-spline technique. However, the goal of this study was not to determine an overall best method, but to present a comprehensive catalogue of methods in a uniform terminology, to define general properties and requirements of local techniques, and to enable the reader to select that method which is optimal for his specific application in medical imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the use of windows for harmonic analysis with the discrete Fourier transform
Harris, F. J. (1978) · Proceedings of the IEEE · doi:10.1109/proc.1978.10837 · Cited by 7,326 · cited 1×
“A systematic approach on the use of windows for harmonic analysis with the discrete Fourier transform is given by Harris who declared the Kaiser–Bessel and Blackman–Harris windows to be the top performers [27].”
MethodCubic convolution interpolation for digital image processing
Keys, R. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163711 · Cited by 3,255
Buckingham, R. A. (1966) · Cited by 2,899
Cubic splines for image interpolation and digital filtering
Hou, H., & Andrews, H. (1978) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1978.1163154 · Cited by 1,270
B-spline signal processing. I. Theory
Unser, M., Aldroubi, A., & Eden, M. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193220 · Cited by 940
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Comparison of Interpolating Methods for Image Resampling
Parker, J. A., Kenyon, R. V., & Troxel, D. E. (1983) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1983.4307610 · Cited by 829
B-spline signal processing. II. Efficiency design and applications
Unser, M., Aldroubi, A., & Eden, M. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193221 · Cited by 641
B-SPLINE SIGNAL PROCESSING: PART I-THEORY
Unser, M. A., Aldroubi, A., & Eden, M. (1993) · Cited by 626
A digital signal processing approach to interpolation
Schafer, R. W., & Rabiner, L. R. (1973) · Proceedings of the IEEE · doi:10.1109/proc.1973.9150 · Cited by 554
Cited by
Image registration methods: a survey
Zitová, B., & Flusser, J. (2003) · Image and Vision Computing · doi:10.1016/s0262-8856(03)00137-9 · Cited by 6,423
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
An edge-guided image interpolation algorithm via directional filtering and data fusion
Zhang, L., & Wu, X. (2006) · IEEE Transactions on Image Processing · doi:10.1109/tip.2006.877407 · Cited by 1,020
A chronology of interpolation: from ancient astronomy to modern signal and image processing
Meijering, E. (2002) · Proceedings of the IEEE · doi:10.1109/5.993400 · Cited by 662
Channel estimation for wireless ofdm systems
Ozdemir, M., & Arslan, H. (2007) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2007.382406 · Cited by 641
Scattered data interpolation methods for electronic imaging systems: a survey
Amidror, I. (2002) · Journal of Electronic Imaging · doi:10.1117/1.1455013 · Cited by 637
AI-assisted CT imaging analysis for COVID-19 screening: Building and deploying a medical AI system
Wang, B., Jin, S., Yan, Q., Xu, H., Luo, C., Wei, L., Zhao, W., Hou, X., Ma, W., Xu, Z., et al. (2021) · Applied Soft Computing · doi:10.1016/j.asoc.2020.106897 · Cited by 538
Stalder, A. F., Russe, M. F., Frydrychowicz, A., Bock, J., Hennig, J., & Markl, M. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21778 · Cited by 474
Radiomics in Oncology: A Practical Guide
Shur, J. D., Doran, S. J., Kumar, S., ap Dafydd, D., Downey, K., O’Connor, J. P. B., Papanikolaou, N., Messiou, C., Koh, D.-M., & Orton, M. R. (2021) · RadioGraphics · doi:10.1148/rg.2021210037 · Cited by 378
Spatially isotropic four-dimensional imaging with dual-view plane illumination microscopy
Wu, Y., Wawrzusin, P., Senseney, J., Fischer, R. S., Christensen, R., Santella, A., York, A. G., Winter, P. W., Waterman, C. M., Bao, Z., et al. (2013) · Nature Biotechnology · doi:10.1038/nbt.2713 · Cited by 322
Image super-resolution: A comprehensive review, recent trends, challenges and applications
Lepcha, D. C., Goyal, B., Dogra, A., & Goyal, V. (2023) · Information Fusion · doi:10.1016/j.inffus.2022.10.007 · Cited by 305
Data hiding method using image interpolation
Jung, K.-H., & Yoo, K.-Y. (2009) · Computer Standards & Interfaces · doi:10.1016/j.csi.2008.06.001 · Cited by 288
Brain Functional Localization: A Survey of Image Registration Techniques
Gholipour, A., Kehtarnavaz, N., Briggs, R., Devous, M., & Gopinath, K. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.892508 · Cited by 274
Manjón, J. V., Coupé, P., Buades, A., Fonov, V., Louis Collins, D., & Robles, M. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.05.010 · Cited by 271
A Survey of Medical Image Registration on Multicore and the GPU
Shams, R., Sadeghi, P., Kennedy, R., & Hartley, R. (2010) · IEEE Signal Processing Magazine · doi:10.1109/msp.2009.935387 · Cited by 198
Evaluating fMRI preprocessing pipelines
Strother, S. C. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1607667 · Cited by 169
“Whether one of these schemes or some other is used, most interpolation approaches leave residual errors in the realigned volumes [28], [43] (trilinear interpolation leaves much larger residual errors than sinc-related and Bspline schemes [41], [42]).”
BackgroundGPU Accelerated Generation of Digitally Reconstructed Radiographs for 2-D/3-D Image Registration
Dorgham, O. M., Laycock, S. D., & Fisher, M. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2207898 · Cited by 56
Fusing multi-scale information in convolution network for MR image super-resolution reconstruction
Liu, C., Wu, X., Yu, X., Tang, Y., Zhang, J., & Zhou, J. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0546-9 · Cited by 47
Kernel regression estimation of fiber orientation mixtures in diffusion MRI
Cabeen, R. P., Bastin, M. E., & Laidlaw, D. H. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.11.061 · Cited by 37
Effects of data count and image scaling on Deep Learning training
Hirahara, D., Takaya, E., Takahara, T., & Ueda, T. (2020) · PeerJ Computer Science · doi:10.7717/peerj-cs.312 · Cited by 27
Effect of the Pixel Interpolation Method for Downsampling Medical Images on Deep Learning Accuracy
Hirahara, D., Takaya, E., Kadowaki, M., Kobayashi, Y., & Ueda, T. (2021) · Journal of Computer and Communications · doi:10.4236/jcc.2021.911010 · Cited by 24
(2025) · doi:10.4103/jiaps.jiaps_168_24 · Cited by 8
Metadata
- Authors
- Lehmann, T. M., Gonner, C., & Spitzer, K.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1999
- Volume
- 18
- Issue
- 11
- Pages
- 1049-1075
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2113524221
- Cited by
- 1,340
- References
- 22
- FWCI
- 15.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.