The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Landmark-based elastic registration using approximating thin-plate splines
Abstract
We consider elastic image registration based on a set of corresponding anatomical point landmarks and approximating thin-plate splines. This approach is an extension of the original interpolating thin-plate spline approach and allows to take into account landmark localization errors. The extension is important for clinical applications since landmark extraction is always prone to error. Our approach is based on a minimizing functional and can cope with isotropic as well as anisotropic landmark errors. In particular, in the latter case it is possible to include different types of landmarks, e.g., unique point landmarks as well as arbitrary edge points. Also, the scheme is general with respect to the image dimension and the order of smoothness of the underlying functional. Optimal affine transformations as well as interpolating thin-plate splines are special cases of this scheme. To localize landmarks we use a semi-automatic approach which is based on three-dimensional (3-D) differential operators. Experimental results are presented for two-dimensional as well as 3-D tomographic images of the human brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spline Models for Observational Data
Wahba, G. (1990) · doi:10.1137/1.9781611970128 · Cited by 4,184
Cited by
Image registration methods: a survey
Zitová, B., & Flusser, J. (2003) · Image and Vision Computing · doi:10.1016/s0262-8856(03)00137-9 · Cited by 6,423
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“Furthermore, TPS do not take into consideration possible errors in the estimation of the displacements in the landmark positions [110].”
BackgroundA new point matching algorithm for non-rigid registration
Chui, H., & Rangarajan, A. (2003) · Computer Vision and Image Understanding · doi:10.1016/s1077-3142(03)00009-2 · Cited by 1,560
A Review of Geometric Transformations for Nonrigid Body Registration
Holden, M. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.904691 · Cited by 369
Deformable 2D-3D Registration of Vascular Structures in a One View Scenario
Groher, M., Zikic, D., & Navab, N. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2011519 · Cited by 91
Metadata
- Authors
- Rohr, K., Stiehl, H. S., Sprengel, R., Buzug, T. M., Weese, J., & Kuhn, M. H.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2001-06
- Volume
- 20
- Issue
- 6
- Pages
- 526-534
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2125113735
- Cited by
- 424
- References
- 1
- FWCI
- 11.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Landmark-based elastic registration using approximating thin-plate splines. https://app.cochat.ai/papers/10.1109/42.929618
- The paper
- Rohr, K., Stiehl, H. S., Sprengel, R., Buzug, T. M., Weese, J., & Kuhn, M. H. (2001). Landmark-based elastic registration using approximating thin-plate splines. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.929618
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.