The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Automated detection of pulmonary nodules in helical CT images based on an improved template-matching technique
Open accessAbstract
The purpose of this study is to develop a technique for computer-aided diagnosis (CAD) systems to detect lung nodules in helical X-ray pulmonary computed tomography CT) images. We propose a novel template-matching technique based on a genetic algorithm (GA) template matching (GATM) for detecting nodules existing within the lung area; the GA was used to determine the target position in the observed image efficiently and to select an adequate template image from several reference patterns for quick template matching. In addition, a conventional template matching was employed to detect nodules existing on the lung wall area, lung wall template matching (LWTM), where semicircular models were used as reference patterns; the semicircular models were rotated according to the angle of the target point on the contour of the lung wall. After initial detecting candidates using the two template-matching methods, we extracted a total of 13 feature values and used them to eliminate false-positive findings. Twenty clinical cases involving a total of 557 sectional images were used in this study. 71 nodules out of 98 were correctly detected by our scheme (i.e., a detection rate of about 72%), with the number of false positives at approximately 1.1/sectional image. Our present results show that our scheme can be regarded as a technique for CAD systems to detect nodules in helical CT pulmonary images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886
Ballard, D. H., & Brown, C. M. (1982) · Cited by 5,303
Greenlee, R. T., Murray, T., Bolden, S., & Wingo, P. A. (2000) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.50.1.7 · Cited by 3,850
Genetic Algorithms + Data Structures = Evolution Programs
Michalewicz, Z. (1994) · Springer eBooks · doi:10.1007/978-3-662-07418-3 · Cited by 2,158
Jähne, B. (1991) · Springer eBooks · doi:10.1007/978-3-662-11565-7 · Cited by 1,222
de la Maza, M. (1993) · ACM SIGART Bulletin · doi:10.1145/152941.1064724 · Cited by 1,088
Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography.
Kaneko, M., Eguchi, K., Ohmatsu, H., Kakinuma, R., Naruke, T., Suemasu, K., & Moriyama, N. (1996) · Radiology · doi:10.1148/radiology.201.3.8939234 · Cited by 831
Texture features for classification of ultrasonic liver images
Wu, C.-M., Chen, Y.-C., & Hsieh, K.-S. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.141636 · Cited by 476
Computerized Detection of Pulmonary Nodules on CT Scans
Armato, S. G., Giger, M. L., Moran, C. J., Blackburn, J. T., Doi, K., & MacMahon, H. (1999) · Radiographics · doi:10.1148/radiographics.19.5.g99se181303 · Cited by 380
Computerized Detection of Pulmonary Nodules in Computed Tomography Images
GIGER, M. L., BAE, K. T., & MacMAHON, H. (1994) · Investigative Radiology · doi:10.1097/00004424-199404000-00013 · Cited by 200
McNitt‐Gray, M. F., Hart, E. M., Wyckoff, N., Sayre, J. W., Goldin, J. G., & Aberle, D. R. (1999) · Medical Physics · doi:10.1118/1.598603 · Cited by 184
Vessel tree reconstruction in thoracic CT scans with application to nodule detection
Gady Agam, B., Armato, S. G., & Wu, C. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.844167 · Cited by 174
Non-small-cell lung cancer: results of the New York screening program.
Heelan, R. T., Flehinger, B. J., Melamed, M. R., Zaman, M., Perchick, W. B., Caravelli, J. F., & Martini, N. (1984) · Radiology · doi:10.1148/radiology.151.2.6324279 · Cited by 152
Quantitative surface characterization of pulmonary nodules based on thin-section CT images
Kawata, Y., Niki, N., Ohmatsu, H., Kakinuma, R., Eguchi, K., Kaneko, M., & Moriyama, N. (1998) · IEEE Transactions on Nuclear Science · doi:10.1109/23.708321 · Cited by 86
Cited by
A review on genetic algorithm: past, present, and future
Katoch, S., Chauhan, S. S., & Kumar, V. (2021) · Multimedia Tools and Applications · doi:10.1007/s11042-020-10139-6 · Cited by 4,655
CE-Net: Context Encoder Network for 2D Medical Image Segmentation
Gu, Z., Cheng, J., Fu, H., Zhou, K., Hao, H., Zhao, Y., Zhang, T., Gao, S., & Liu, J. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2903562 · Cited by 2,267
Computer analysis of computed tomography scans of the lung: a survey
Sluimer, I., Schilham, A., Prokop, M., & van Ginneken, B. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.862753 · Cited by 556
Current status and future potential of computer-aided diagnosis in medical imaging
Doi, K. (2005) · The British Journal of Radiology · doi:10.1259/bjr/82933343 · Cited by 444
A new computationally efficient CAD system for pulmonary nodule detection in CT imagery
Messay, T., Hardie, R. C., & Rogers, S. K. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.02.004 · Cited by 439
Metadata
- Authors
- Lee, Y., Hara, T., Fujita, H., Itoh, S., & Ishigaki, T.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2001-07
- Volume
- 20
- Issue
- 7
- Pages
- 595-604
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2109711012
- Cited by
- 457
- References
- 14
- FWCI
- 14.27
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.