Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 457

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

The distribution of target registration error in rigid-body point-based registration

Fitzpatrick, J.M., West, J.B.·2001·IEEE Transactions on Medical Imaging

Abstract

Guidance systems designed for neurosurgery, hip surgery, spine surgery and for approaches to other anatomy that is relatively rigid can use rigid-body transformations to accomplish image registration. These systems often rely on point-based registration to determine the transformation and many such systems use attached fiducial markers to establish accurate fiducial points for the registration, the points being established by some fiducial localization process. Accuracy is important to these systems, as is knowledge of the level of that accuracy. An advantage of marker-based systems, particularly those in which the markers are bone-implanted, is that registration error depends only on the fiducial localization and is, thus, to a large extent independent of the particular object being registered. Thus, it should be possible to predict the clinical accuracy of marker-based systems on the basis of experimental measurements made with phantoms or previous patients. For most registration tasks, the most important error measure is target registration error (TRE), which is the distance after registration between corresponding points not used in calculating the registration transform. In this paper, we derive an approximation to the distribution of TRE; this is an extension of previous work that gave the expected squared value of TRE. We show the distribution of the squared magnitude of TRE and that of the component of TRE in an arbitrary direction. Using numerical simulations, we show that our theoretical results are a close match to the simulated ones.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/42.952729

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 457

Metadata

Authors
Fitzpatrick, J. M., & West, J. B.
Venue
IEEE Transactions on Medical Imaging
Published
2001
Volume
20
Issue
9
Pages
917-927
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2113094491
Cited by
457
References
21
FWCI
9.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The distribution of target registration error in rigid-body point-based registration. https://app.cochat.ai/papers/10.1109/42.952729
The paper
Fitzpatrick, J. M., & West, J. B. (2001). The distribution of target registration error in rigid-body point-based registration. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.952729

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.