The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Three-dimensional computer-aided diagnosis scheme for detection of colonic polyps
Abstract
We have developed a three-dimensional (3-D) computer-aided diagnosis scheme for automated detection of colonic polyps in computed tomography (CT) colonographic data sets, and assessed its performance based on colonoscopy as the gold standard. In this scheme, a thick region encompassing the entire colonic wall is extracted from an isotropic volume reconstructed from the CT images in CT colonography. Polyp candidates are detected by first computing of 3-D geometric features that characterize polyps, folds, and colonic walls at each voxel in the extracted colon, and then segmenting of connected components corresponding to suspicious regions by hysteresis thresholding based on these geometric features. We apply fuzzy clustering to these connected components to obtain the polyp candidates. False-positive (FP) detections are then reduced by computation of several 3-D volumetric features characterizing the internal structures of the polyp candidates, followed by the application of discriminant analysis to the feature space generated by these volumetric features. The locations of the polyps detected by our computerized method were compared to the gold standard of conventional colonoscopy. The performance was evaluated based on 43 clinical cases, including 12 polyps determined by colonoscopy. Our computerized scheme was shown to have the potential to detect polyps in CT colonography with a clinically acceptable high sensitivity and a low FP rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Statistical Pattern Recognition
(1990) · Elsevier eBooks · doi:10.1016/c2009-0-27872-x · Cited by 11,031
The Jackknife, the Bootstrap and Other Resampling Plans
Efron, B. (1982) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9781611970319 · Cited by 8,120
Statistical pattern recognition: a review
Jain, A. K., Duin, P. W., & Mao, J. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824819 · Cited by 6,767
Foundations of Differential Geometry
Kobayashi, S., & Nomizu, K. (1963) · UCLA - Biblioteca de Ciencias y Tecnologia Felix Morales Bueno · Cited by 6,384
Three-dimensional computer vision: a geometric viewpoint
(1994) · Choice Reviews Online · doi:10.5860/choice.32-0357 · Cited by 3,030
On the foundations of differential geometry
Rubio, R. (1964) · Časopis pro pěstování matematiky · doi:10.21136/cpm.1964.117506 · Cited by 1,959
Colorectal cancer screening: Clinical guidelines and rationale
Winawer, S., Fletcher, R., Miller, L., Godlee, F., Stolar, M., Mulrow, C., Woolf, S., Glick, S., Ganiats, T., Bond, J., et al. (1997) · Gastroenterology · doi:10.1053/gast.1997.v112.agast970594 · Cited by 1,612
Some Practical Issues of Experimental Design and Data Analysis in Radiological ROC Studies
METZ, C. E. (1989) · Investigative Radiology · doi:10.1097/00004424-198903000-00012 · Cited by 859
Koenderink, J. J. (1990) · Cited by 827
O'Brien, M. J., Winawer, S. J., Zauber, A. G., Gottlieb, L. S., Sternberg, S. S., Diaz, B., Dickersin, G. R., Ewing, S., Geller, S., Kasimian, D., et al. (1990) · Gastroenterology · doi:10.1016/0016-5085(90)90827-n · Cited by 818
Metz, C. E., Herman, B. A., & Shen, J.-H. (1998) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19980515)17:9<1033::aid-sim784>3.0.co;2-z · Cited by 793
A Comparison of Virtual and Conventional Colonoscopy for the Detection of Colorectal Polyps
Fenlon, H. M., Nunes, D. P., Schroy, P. C., Barish, M. A., Clarke, P. D., & Ferrucci, J. T. (1999) · New England Journal of Medicine · doi:10.1056/nejm199911113412003 · Cited by 746
Flat and depressed colonic neoplasms: a prospective study of 1000 colonoscopies in the UK
Rembacken, B., Fujii, T., Cairns, A., Dixon, M., Yoshida, S., Chalmers, D., & Axon, A. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02086-9 · Cited by 656
COSMOS-A representation scheme for 3D free-form objects
Dorai, C., & Jain, A. K. (1997) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.625113 · Cited by 438
Perspective volume rendering of CT and MR images: applications for endoscopic imaging.
Rubin, G. D., Beaulieu, C. F., Argiro, V., Ringl, H., Norbash, A., Feller, J. F., Dake, M. D., Jeffrey, R. B., & Napel, S. A. (1996) · Radiology · doi:10.1148/radiology.199.2.8668772 · Cited by 397
Saitoh, Y., Waxman, I., West, A. B., Popnikolov, N. K., Gatalica, Z., Watari, J., Obara, T., Kohgo, Y., & Pasricha, P. J. (2001) · Gastroenterology · doi:10.1053/gast.2001.24886 · Cited by 369
Optimization of CT Colonography Technique: Prospective Trial in 180 Patients
Fletcher, J. G., Johnson, C. D., Welch, T. J., MacCarty, R. L., Ahlquist, D. A., Reed, J. E., Harmsen, W. S., & Wilson, L. A. (2000) · Radiology · doi:10.1148/radiology.216.3.r00au41704 · Cited by 342
Yoshida, H., Masutani, Y., MacEneaney, P., Rubin, D. T., & Dachman, A. H. (2002) · Radiology · doi:10.1148/radiol.2222010506 · Cited by 243
Self-citationAutomated Polyp Detector for CT Colonography: Feasibility Study
Summers, R. M., Beaulieu, C. F., Pusanik, L. M., Malley, J. D., Jeffrey, R. B., Glazer, D. I., & Napel, S. (2000) · Radiology · doi:10.1148/radiology.216.1.r00jl43284 · Cited by 213
A novel approach to extract colon lumen from CT images for virtual colonoscopy
Chen, D., Wax, M. R., Li, L. C., Liang, Z., Li, B., & Kaufman, A. E. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.897814 · Cited by 118
Quantitative surface characterization of pulmonary nodules based on thin-section CT images
Kawata, Y., Niki, N., Ohmatsu, H., Kakinuma, R., Eguchi, K., Kaneko, M., & Moriyama, N. (1998) · IEEE Transactions on Nuclear Science · doi:10.1109/23.708321 · Cited by 86
Näppi, J. J., Dachman, A. H., MacEneaney, P. M., & Yoshida, H. (2002) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200207000-00003 · Cited by 61
Self-citation
Cited by
Overview of deep learning in medical imaging
Suzuki, K. (2017) · Radiological Physics and Technology · doi:10.1007/s12194-017-0406-5 · Cited by 1,087
Machine learning and radiology
Wang, S., & Summers, R. M. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.02.005 · Cited by 697
Current status and future potential of computer-aided diagnosis in medical imaging
Doi, K. (2005) · The British Journal of Radiology · doi:10.1259/bjr/82933343 · Cited by 444
Content-based image retrieval in radiology: current status and future directions
Akgül, C. B., Rubin, D. L., Napel, S., Beaulieu, C. F., Greenspan, H., & Acar, B. (2011) · Journal of Digital Imaging · doi:10.1007/s10278-010-9290-9 · Cited by 388
Shape-Based Computer-Aided Detection of Lung Nodules in Thoracic CT Images
Ye, X., Lin, X., Dehmeshki, J., Slabaugh, G., & Beddoe, G. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2017027 · Cited by 297
Metadata
- Authors
- Yoshida, H., & Nappi, J.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2001
- Volume
- 20
- Issue
- 12
- Pages
- 1261-1274
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2038839211
- Cited by
- 343
- References
- 22
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.