The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
An axial velocity estimator for ultrasound blood flow imaging, based on a full evaluation of the Doppler equation by means of a two-dimensional autocorrelation approach
Abstract
This paper introduces a new velocity estimator, referred to as the 2D autocorrelator, which differs from conventional Doppler techniques in two respects: the derivation of axial velocity values by evaluating the Doppler equation using explicit estimates of both the mean Doppler and the mean RF frequency at each range gate location; and, the 2D nature (depth samples versus pulse transmissions) of processing within the range gate. The estimator's output can be calculated by evaluating the 2D autocorrelation function of the demodulated (baseband) backscattered echoes at two lags. A full derivation and mathematical description of the estimator is presented, based on the framework of the 2D Fourier transform. The same framework is adopted to analyze two other established velocity estimators (the conventional 1D autocorrelator and the crosscorrelator) in a unifying manner, and theoretical arguments as well as experimental results are used to highlight the common aspects of all three estimators. In addition, a thorough performance evaluation is carried out by means of extensive simulations, which document the effect of a number of factors (velocity spread, range gate length, ensemble length, noise level, transmitted bandwidth) and provide an insight into the optimum parameters and trade-offs associated with individual algorithms. Overall, the 2D autocorrelator is shown to offer the best performance in the context of the specific simulation conditions considered here. Its superiority over the crosscorrelator is restricted to cases of low signal-to-noise ratios. However, the 2D autocorrelator always outperforms the conventional 1D autocorrelator by a significant margin. These comparisons, when linked to the computational requirements of the proposed estimator, suggest that it combines the generally higher performance of 2D broadband time-domain techniques with the relatively modest complexity of 1D narrowband phase-domain velocity estimators.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Probability, Random Variables, and Stochastic Processes.
Abrahams, J., & Papoulis, A. (1984) · Journal of the American Statistical Association · doi:10.2307/2288754 · Cited by 16,226
The Fourier Transform and Its Applications
Bracewell, R., & Kahn, P. B. (1966) · American Journal of Physics · doi:10.1119/1.1973431 · Cited by 5,737
Random variables and stochastic processes
Larson, H. J., & Shubert, B. O. (1979) · Wiley eBooks · Cited by 4,640
Probability, random variables and stochastic processes
Proakis, J. (1985) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1985.1164715 · Cited by 4,568
Two-Dimensional Signal and Image Processing
Lim, J. S. (1989) · Medical Entomology and Zoology · Cited by 2,561
Engineering Applications of Correlation and Spectral Analysis.
Tolley, H. D., Bendat, J. S., & Piersol, A. G. (1982) · Journal of the American Statistical Association · doi:10.2307/2287747 · Cited by 1,678
Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique
Kasai, C., Namekawa, K., Koyano, A., & Omoto, R. (1985) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1985.31615 · Cited by 1,255
Coherence and time delay estimation
Carter, G. C. (1987) · Proceedings of the IEEE · doi:10.1109/proc.1987.13723 · Cited by 1,200
Image Reconstruction from Projections
(2004) · Biomedical Engineering · doi:10.1201/9780203492543.ch9 · Cited by 915
Engineering applications of correlation and spectral analysis
Robson, J. D. (1981) · Journal of Sound and Vibration · doi:10.1016/0022-460x(81)90424-7 · Cited by 827
Introduction to digital signal processing
(1988) · Choice Reviews Online · doi:10.5860/choice.26-0328 · Cited by 638
Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique
Kasai, C., & Namekawa, K. (1985) · IEEE 1985 Ultrasonics Symposium · doi:10.1109/ultsym.1985.198654 · Cited by 573
Discrete time techniques for time delay estimation
Jacovitti, G., & Scarano, G. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193195 · Cited by 433
Bonnefous, O. (1986) · Ultrasonic Imaging · doi:10.1016/0161-7346(86)90001-5 · Cited by 343
Hein, I. A., & O'Brien, W. D. (1993) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.212556 · Cited by 309
Doppler Ultrasound: Physics, Instrumentation and Clinical Applications
Ritenour, E. R. (1990) · Radiology · doi:10.1148/radiology.177.2.346 · Cited by 289
Time delay estimation via cross-correlation in the presence of large estimation errors
Ianniello, J. (1982) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1982.1163992 · Cited by 270
Flow velocity profile via time-domain correlation: error analysis and computer simulation
Foster, S. G., Embree, P. M., & O'Brien, W. D. (1990) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.55306 · Cited by 227
Loupas, T., Peterson, R. B., & Gill, R. W. (1995) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.393111 · Cited by 189
Self-citationde Jong, P. G. M., Arts, T. G. J., Hoeks, A. P. G., & Reneman, R. S. (1990) · Ultrasonic Imaging · doi:10.1177/016173469001200202 · Cited by 141
Special issue on time delay estimation
Carter, G. (1980) · Cited by 132
Volumetric blood flow via time-domain correlation: experimental verification
Embree, P. M., & O’Brien, W. D. (1990) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.55307 · Cited by 118
A new wideband spread target maximum likelihood estimator for blood velocity estimation. I. Theory
Ferrara, K. W., & Algazi, V. R. (1991) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.67829 · Cited by 114
Hoeks, A. P. G., Arts, T. G. J., Brands, P. J., et al. (1993) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(93)90090-b · Cited by 101
A note on the application of the Hilbert transform to time delay estimation
Cabot, R. (1981) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/tassp.1981.1163564 · Cited by 97
On the determination of the position of extrema of sampled correlators
Moddemeijer, R. (1991) · IEEE Transactions on Signal Processing · doi:10.1109/78.80788 · Cited by 87
On the simulation of a class of time delay estimation algorithms
Scarbrough, K., Ahmed, N., & Carter, G. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163615 · Cited by 79
Comparison of various time delay estimation methods by computer simulation
Fertner, A., & Sjölund, A. (1986) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/tassp.1986.1164930 · Cited by 76
A New Velocity Estimator for Color Flow Mapping
Bonnefous, O., Pesque, P., & Bernard, X. (1986) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.1986.198856 · Cited by 60
DEJONG, P., Arts, T. G. J., Hoeks, A. P. G., & Reneman, R. S. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90081-r · Cited by 54
A velocity evaluation phantom for colour and pulsed doppler instruments
Rickey, D. W., Rankin, R. N., & Fenster, A. (1992) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(92)90088-r · Cited by 53
Ferrara, K. W., & Algazi, V. R. (1991) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.67830 · Cited by 47
Loupas, T., & Gill, R. W. (1994) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.294114 · Cited by 32
Self-citationRange/velocity limitations for time-domain blood velocity estimation
Jensen, J. A. (1993) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(93)90091-2 · Cited by 31
A real-time ultrasound time-domain correlation blood flowmeter. I. Theory and design
Hein, I. A., Chen, J. T., Jenkins, W. K., et al. (1993) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.248222 · Cited by 27
Hein, I. A., & O’Brien, W. D. (1993) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.248223 · Cited by 25
Cited by
Ultrafast compound doppler imaging: providing full blood flow characterization
Bercoff, J., Montaldo, G., Loupas, T., Savery, D., Mézière, F., Fink, M., & Tanter, M. (2011) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.1780 · Cited by 510
Self-citationTwo-dimensional temperature estimation using diagnostic ultrasound
Simon, C., VanBaren, P., & Ebbini, E. S. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.710592 · Cited by 433
Speckle tracking methods for ultrasonic elasticity imaging using short-time correlation
Lubinski, M. A., Emelianov, S. Y., & O'Donnell, M. (1999) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.741427 · Cited by 379
Deep learning in ultrasound imaging
van Sloun, R. J. G., Cohen, R., & Eldar, Y. C. (2020) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2932116 · Cited by 316
Review of Photoacoustic Flow Imaging: Its Current State and Its Promises
van den Berg, P. J., Daoudi, K., & Steenbergen, W. (2015) · Photoacoustics · doi:10.1016/j.pacs.2015.08.001 · Cited by 84
Metadata
- Authors
- Loupas, T., Powers, J. T., & Gill, R. W.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 1995-07
- Volume
- 42
- Issue
- 4
- Pages
- 672-688
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2153608106
- Cited by
- 560
- References
- 36
- FWCI
- 6.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.