The DOI matches its Crossref record.
A preliminary evaluation of the effects of primary and secondary radiation forces on acoustic contrast agents
Abstract
Primary and secondary radiation forces result from pressure gradients in the incident and scattered ultrasonic fields. These forces and their dependence on experimental parameters are described, and the theory for primary radiation force is extended to consider a pulsed traveling wave. Both primary and secondary radiation forces are shown to have a significant effect on the flow of microbubbles through a small vessel during insonation. The primary radiation force produces displacement of microspheres across a 100 micron vessel radius for a small transmitted acoustic pressure. The displacement produced by primary radiation force is shown to display the expected linear dependence on the pulse repetition frequency and a nonlinear dependence on transmitted pressure. The secondary radiation force produces a reversible attraction and aggregation of microspheres with a significant attraction over a distance of approximately 100 microns. The magnitude of the secondary radiation force is proportional to the inverse of the squared separation distance, and thus two aggregates accelerate as they approach one another. We show that this force is sufficient to produce aggregates that remain intact for a physiologically appropriate shear rate. Brief interruption of acoustic transmission allows an immediate disruption of the aggregate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microbubbles in ultrasound-triggered drug and gene delivery
Hernot, S., & Klibanov, A. L. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.005 · Cited by 990
Self-citationMicrobubble compositions, properties and biomedical applications
Sirsi, S. R., & Borden, M. A. (2009) · Bubble Science, Engineering & Technology · doi:10.1179/175889709x446507 · Cited by 594
Ultrasound contrast microbubbles in imaging and therapy: physical principles and engineering
Qin, S., Caskey, C. F., & Ferrara, K. W. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/6/r01 · Cited by 453
Self-citationMicrobubble ultrasound contrast agents: A review
Stride, E., & Saffari, N. (2003) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544110360729072 · Cited by 337
Acoustic radiation force in vivo: a mechanism to assist targeting of microbubbles
Dayton, P., Klibanov, A., Brandenburger, G., & Ferrara, K. (1999) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00062-9 · Cited by 330
Self-citation
Metadata
- Authors
- Dayton, P. A., Morgan, K. E., Klibanov, A. L., Brandenburger, G., Nightingale, K. R., & Ferrara, K. W.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 1997-11
- Volume
- 44
- Issue
- 6
- Pages
- 1264-1277
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2004205666
- Cited by
- 231
- References
- 0
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A preliminary evaluation of the effects of primary and secondary radiation forces on acoustic contrast agents. https://app.cochat.ai/papers/10.1109/58.656630
- The paper
- Dayton, P. A., Morgan, K. E., Klibanov, A. L., Brandenburger, G., Nightingale, K. R., & Ferrara, K. W. (1997). A preliminary evaluation of the effects of primary and secondary radiation forces on acoustic contrast agents. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. https://doi.org/10.1109/58.656630
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.