Unsynchronized two-terminal fault location estimation
Abstract
A technique for power system fault location estimation which uses data from both ends of a transmission line and which does not require the data to be synchronized is described. The technique fully utilizes the advantages of digital technology and numerical relaying which are available today and can easily be applied for offline analysis. This technique allows for accurate estimation of the fault location irrespective of the fault type, fault resistance, load currents, and source impedances. Use of two-terminal data allows the algorithm to eliminate previous assumptions in fault location estimation, thus increasing the accuracy of the estimate. The described scheme does not require real-time communications, only offline post-fault analysis. The paper also presents fault analysis techniques utilizing the additional communicated information.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of a New Type Fault Locator Using the One-Terminal Voltage and Current Data
Takagi, T., Yamakoshi, Y., Yamaura, M., Kondow, R., & Matsushima, T. (1982) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1982.317615 · Cited by 635
A new fault location technique for two- and three-terminal lines
Girgis, A. A., Hart, D. G., & Peterson, W. L. (1992) · IEEE Transactions on Power Delivery · doi:10.1109/61.108895 · Cited by 374
Self-citationSachdev, M. S., & Agarwal, R. (1988) · IEEE Transactions on Power Delivery · doi:10.1109/61.4237 · Cited by 235
Lawrence, D. J., Cabeza, L. Z., & Hochberg, L. T. (1992) · IEEE Transactions on Power Delivery · doi:10.1109/61.157001 · Cited by 53
Schweitzer, E. O. (1983) · Computers & Electrical Engineering · doi:10.1016/0045-7906(83)90013-7 · Cited by 52
Cited by
Smart Fault Location for Smart Grids
Kezunovic, M. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2118774 · Cited by 380
Time Synchronization Attack in Smart Grid: Impact and Analysis
Zhang, Z., Gong, S., Dimitrovski, A. D., & Li, H. (2013) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2227342 · Cited by 325
Fault Diagnosis for Electrical Systems and Power Networks: A Review
Furse, C. M., Kafal, M., Razzaghi, R., & Shin, Y.-J. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2987321 · Cited by 296
Metadata
- Authors
- Novosel, D., Hart, D. G., Udren, E., & Garitty, J.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 1996
- Volume
- 11
- Issue
- 1
- Pages
- 130-138
- ISSN
- 0885-8977 (ISSN-L)
- OpenAlex
- W2061108605
- Cited by
- 270
- References
- 5
- FWCI
- 8.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Unsynchronized two-terminal fault location estimation. https://app.cochat.ai/papers/10.1109/61.484009
- The paper
- Novosel, D., Hart, D. G., Udren, E., & Garitty, J. (1996). Unsynchronized two-terminal fault location estimation. IEEE Transactions on Power Delivery. https://doi.org/10.1109/61.484009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.