The DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Fault Diagnosis for Electrical Systems and Power Networks: A Review
Abstract
In this paper, we review the state of the art in the detection, location, and diagnosis of faults in electrical wiring interconnection systems (EWIS) including in the electric power grid and vehicles and machines. Most electrical test methods rely on measurements of either currents and voltages or on high frequency reflections from impedance discontinuities. Of these high frequency test methods, we review phasor, travelling wave and reflectometry methods. The reflectometry methods summarized include time domain reflectometry (TDR), sequence time domain reflectometry (STDR), spread spectrum time domain reflectometry (SSTDR), orthogonal multi-tone reflectometry (OMTDR), noise domain reflectometry (NDR), chaos time domain reflectometry (CTDR), binary time domain reflectometry (BTDR), frequency domain reflectometry (FDR), multicarrier reflectometry (MCR), and time-frequency domain reflectometry (TFDR). All of these reflectometry methods result in complex data sets (reflectometry signatures) that are the result of reflections in the time/frequency/spatial domains. Automated analysis techniques are needed to detect, locate, and diagnose the fault including genetic algorithm (GA), neural networks (NN), particle swarm optimization, teaching-learning-based optimization, backtracking search optimization, inverse scattering, and iterative approaches. We summarize several of these methods including electromagnetic time-reversal (TR) and the matched-pulse (MP) approach. We also discuss the issue of soft faults (small impedance changes) and methods to augment their signatures, and the challenges of branched networks. We also suggest directions for future research and development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vibration Based Condition Monitoring: A Review
Carden, E. P., & Fanning, P. (2004) · Structural Health Monitoring · doi:10.1177/1475921704047500 · Cited by 1,543
A Summary Review of Wireless Sensors and Sensor Networks for Structural Health Monitoring
Lynch, J. P. (2006) · The Shock and Vibration Digest · doi:10.1177/0583102406061499 · Cited by 1,533
A review of structural health monitoring literature 1996-2001
Farrar, C. R., Czarnecki, J. J., Hoon Sohn, A., & Hemez, F. (2002) · Cited by 1,496
Guided wave based structural health monitoring: A review
Mitra, M., & Gopalakrishnan, S. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/5/053001 · Cited by 1,045
Fault Location on Power Networks
Saha, M. M., Iżykowski, J., & Rosołowski, E. (2009) · Power systems · doi:10.1007/978-1-84882-886-5 · Cited by 709
Development of a New Type Fault Locator Using the One-Terminal Voltage and Current Data
Takagi, T., Yamakoshi, Y., Yamaura, M., Kondow, R., & Matsushima, T. (1982) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1982.317615 · Cited by 635 · cited 1×
“, [20]–[23]), (ii) doubleend (two-terminal) measurement methods (e.”
Online Diagnosis of Induction Motors Using MCSA
Jung, J.-H., Lee, J.-J., & Kwon, B.-H. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.885131 · Cited by 570
Review of condition monitoring of rotating electrical machines
Tavner, P. J. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070280 · Cited by 531
Structural Health Monitoring in mainland China: Review and Future Trends
Ou, J., & Li, H. (2010) · Structural Health Monitoring · doi:10.1177/1475921710365269 · Cited by 525
Recent developments of induction motor drives fault diagnosis using AI techniques
Filippetti, F., Franceschini, G., Tassoni, C., & Vas, P. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873207 · Cited by 511
Research works printed but not linked: 118
- 10.1109/PIERS-Spring46901.2019.9017914 · doi:10.1109/piers-spring46901.2019.9017914
- 10.1109/TIM.2019.2896369 · doi:10.1109/tim.2019.2896369
- 10.1109/JSEN.2013.2294193 · doi:10.1109/jsen.2013.2294193
- 10.1109/MEMC.2013.6512221 · doi:10.1109/memc.2013.6512221
- 10.1109/TAP.2010.2090462 · doi:10.1109/tap.2010.2090462
- 10.1063/1.2184600 · doi:10.1063/1.2184600
- 10.2528/PIER09071004 · doi:10.2528/pier09071004
- 10.1109/TPWRD.2004.834863 · doi:10.1109/tpwrd.2004.834863
- 10.1109/TSG.2016.2601379 · doi:10.1109/tsg.2016.2601379
- 10.1016/j.ijepes.2018.03.009 · doi:10.1016/j.ijepes.2018.03.009
- 10.1109/TPWRD.2008.2002698 · doi:10.1109/tpwrd.2008.2002698
- 10.1109/TPWRD.2005.858778 · doi:10.1109/tpwrd.2005.858778
- 10.1109/TEMC.2018.2830404 · doi:10.1109/temc.2018.2830404
- 10.1109/TMAG.2010.2089503 · doi:10.1109/tmag.2010.2089503
- shi, 2013, Identification of wire network topology using impedance spectroscopy, Proc 19th Symp IMEKO, 372
- 10.23919/EUSIPCO.2017.8081671 · doi:10.23919/eusipco.2017.8081671
- boudjefdjouf, 2016, Wire fault diagnosis based on time-domain reflectometry and backtracking search optimization algorithm, Appl Comput Electromagn Soc J, 31, 340
- 10.1080/02726343.2015.971659 · doi:10.1080/02726343.2015.971659
- 10.1016/j.compeleceng.2014.07.002 · doi:10.1016/j.compeleceng.2014.07.002
- 10.3233/JAE-2011-1320 · doi:10.3233/jae-2011-1320
- 10.1109/MSNA.2012.6324524 · doi:10.1109/msna.2012.6324524
- 10.1109/TPWRD.2010.2047412 · doi:10.1109/tpwrd.2010.2047412
- 10.1109/MPER.1985.5528881 · doi:10.1109/mper.1985.5528881
- 10.1109/TPWRD.2009.2031440 · doi:10.1109/tpwrd.2009.2031440
- 10.1109/TIM.2009.2014617 · doi:10.1109/tim.2009.2014617
- 10.1109/ITST.2009.5399294 · doi:10.1109/itst.2009.5399294
- hickman, 2009, An acoustic-based wiring diagnostic system for aircraft
- kafal, 2017, Baselining: A critical approach used for soft fault detection in wire networks, Proc 3rd Int Conf Elect Electron Eng Telecommun Eng Mechatronics (EEETEM)
- 10.1109/TASC.2016.2524520 · doi:10.1109/tasc.2016.2524520
- 10.1109/DIAGNOSTIKA.2018.8526121 · doi:10.1109/diagnostika.2018.8526121
- grégis, 2019, Real time detection and localization of self extinguishing defects on a MV network, Proc 25th Int Conf Electr Distrib (CIRED)
- 10.23919/PSCC.2018.8449024 · doi:10.23919/pscc.2018.8449024
- 10.1109/TEMC.2019.2904841 · doi:10.1109/temc.2019.2904841
- 10.1049/iet-gtd.2016.1215 · doi:10.1049/iet-gtd.2016.1215
- 10.1109/TPWRD.1986.4307961 · doi:10.1109/tpwrd.1986.4307961
- 10.1121/1.1738451 · doi:10.1121/1.1738451
- kafal, 2017, Soft fault diagnosis in wire networks using time reversal concept and subspace methods, Proc 3rd Int Conf Elect Electron Eng Telecommun Eng Mechatronics (EEETEM)
- 10.1109/TIM.2016.2578578 · doi:10.1109/tim.2016.2578578
- 10.1109/TMAG.2017.2765463 · doi:10.1109/tmag.2017.2765463
- 10.1016/0165-2125(94)90039-6 · doi:10.1016/0165-2125(94)90039-6
- 10.1109/AUTEST.2018.8532546 · doi:10.1109/autest.2018.8532546
- walker, 1921, The Diagnosing of Troubles in Electrical Machines
- 1990, Institute of Electrical and Electronics Engineers Recommended Practice for Design of Reliable Industrial and Commercial Power Systems (IEEE Gold Book)
- 10.1109/HOLM.2012.6336569 · doi:10.1109/holm.2012.6336569
- 10.1109/TIM.2012.2187246 · doi:10.1109/tim.2012.2187246
- 10.2528/PIERM13032801 · doi:10.2528/pierm13032801
- 10.1109/TPAS.1985.318906 · doi:10.1109/tpas.1985.318906
- 10.1109/TPWRD.2006.878091 · doi:10.1109/tpwrd.2006.878091
- 10.1109/61.108901 · doi:10.1109/61.108901
- 10.1109/TPWRD.2012.2190528 · doi:10.1109/tpwrd.2012.2190528
- 10.1109/61.296245 · doi:10.1109/61.296245
- 10.1177/1475921705049764 · doi:10.1177/1475921705049764
- 10.1109/TDEI.2008.4543119 · doi:10.1109/tdei.2008.4543119
- 10.1109/6.898797 · doi:10.1109/6.898797
- 1997, Lectromec Report Aging Measurements of Operating Aircraft Wiring Implications for Specification Writing and Aircraft Reliability
- yang, 2006, Accurate data collection: Roadmap to proactive aircraft wiring maintenance, Proc 9th Joint FAA/DoD/NASA Conf Aging Aircr
- 2000, Review of federal programs for wire system safety
- 10.1109/ICEAA.2019.8879093 · doi:10.1109/iceaa.2019.8879093
- 10.1109/AUTEST.2018.8532500 · doi:10.1109/autest.2018.8532500
- hassen, 2019, A damaged twisted pair cable modeling for fault detection and characterization using OMTDR and particle swarm algorithm, Sens Transducers, 236, 7
- 10.1109/AUTOTESTCON43700.2019.8961070 · doi:10.1109/autotestcon43700.2019.8961070
- 10.1109/TEMC.2019.2911035 · doi:10.1109/temc.2019.2911035
- 10.1109/AUTEST.2018.8532521 · doi:10.1109/autest.2018.8532521
- 10.1109/AUTEST.2017.8080495 · doi:10.1109/autest.2017.8080495
- 10.1109/JSEN.2005.858900 · doi:10.1109/jsen.2005.858900
- 10.1109/ICSENS.2017.8234208 · doi:10.1109/icsens.2017.8234208
- 10.1109/LSENS.2019.2916636 · doi:10.1109/lsens.2019.2916636
- 10.1109/JSEN.2005.858964 · doi:10.1109/jsen.2005.858964
- 10.1109/ECCE.2013.6646814 · doi:10.1109/ecce.2013.6646814
- shuxu, 2014, Railway signal section cable fault detection based on improved second correlation, J Data Acquisition Process, 23
- 10.1109/ECCE.2014.6953848 · doi:10.1109/ecce.2014.6953848
- 10.1109/HOLM.2010.5619539 · doi:10.1109/holm.2010.5619539
- 10.1109/TAES.2014.120556 · doi:10.1109/taes.2014.120556
- 10.1109/HOLM.2007.4318203 · doi:10.1109/holm.2007.4318203
- 10.1109/JSEN.2009.2019309 · doi:10.1109/jsen.2009.2019309
- 10.1109/TMAG.2010.2043720 · doi:10.1109/tmag.2010.2043720
- 10.12989/sss.2006.2.1.025 · doi:10.12989/sss.2006.2.1.025
- 10.1109/JSEN.2006.874017 · doi:10.1109/jsen.2006.874017
- 10.1109/TEMC.2004.837842 · doi:10.1109/temc.2004.837842
- 2019, Campbell Scientific TDR100 Instruction Manual
- 10.1109/ECCE.2012.6342450 · doi:10.1109/ecce.2012.6342450
- 10.1002/mop.10241 · doi:10.1002/mop.10241
- 10.1109/JSEN.2019.2956942 · doi:10.1109/jsen.2019.2956942
- 10.1109/AUTEST.2018.8532526 · doi:10.1109/autest.2018.8532526
- 10.1109/TIM.2018.2851646 · doi:10.1109/tim.2018.2851646
- 10.1109/TEMC.2005.847403 · doi:10.1109/temc.2005.847403
- 10.1109/TEMC.2003.811305 · doi:10.1109/temc.2003.811305
- 10.1109/JSEN.2006.874018 · doi:10.1109/jsen.2006.874018
- 10.1109/TIM.2005.858115 · doi:10.1109/tim.2005.858115
- 2019, NASA SWR Technology Finds Cable Faults—http //www eclypse org
- 10.1109/JSEN.2005.858894 · doi:10.1109/jsen.2005.858894
- 10.1049/iet-spr.2009.0137 · doi:10.1049/iet-spr.2009.0137
- 10.1109/TEMC.2008.2007964 · doi:10.1109/temc.2008.2007964
- 10.1109/TPWRD.2017.2680459 · doi:10.1109/tpwrd.2017.2680459
- 10.1109/TIM.2010.2058730 · doi:10.1109/tim.2010.2058730
- 10.1109/TIE.2018.2881937 · doi:10.1109/tie.2018.2881937
- 10.1109/ICD.2018.8468508 · doi:10.1109/icd.2018.8468508
- 10.1109/TIM.2017.2664578 · doi:10.1109/tim.2017.2664578
- 1974, Report on reliability survey of industrial plants, parts I,II,III, IEEE Trans Ind Appl, ia 10, 201
- 10.1109/TASC.2017.2650405 · doi:10.1109/tasc.2017.2650405
- 10.1109/TASC.2017.2652330 · doi:10.1109/tasc.2017.2652330
- 10.1109/JSEN.2006.886866 · doi:10.1109/jsen.2006.886866
- 10.1002/stc.69 · doi:10.1002/stc.69
- 10.1109/JPHOTOV.2019.2953392 · doi:10.1109/jphotov.2019.2953392
- 10.1109/JPHOTOV.2019.2953392 · doi:10.1109/jphotov.2019.2953392
- 2019, Live Cable Fault Detection by LiveWire Innovation
- 10.1109/ISSNIP.2013.6529826 · doi:10.1109/issnip.2013.6529826
- 10.1109/AIEEPAS.1957.4499601 · doi:10.1109/aieepas.1957.4499601
- 10.1109/TEMC.2004.842109 · doi:10.1109/temc.2004.842109
- 10.2528/PIERM12111707 · doi:10.2528/pierm12111707
- 10.1109/ICIEA.2015.7334396 · doi:10.1109/iciea.2015.7334396
- 10.1155/2015/538643 · doi:10.1155/2015/538643
- 10.1109/ICSENS.2017.8234174 · doi:10.1109/icsens.2017.8234174
- 10.1109/AUTEST.2018.8532560 · doi:10.1109/autest.2018.8532560
- 10.1007/s11071-014-1888-x · doi:10.1007/s11071-014-1888-x
- 10.1049/el.2015.3456 · doi:10.1049/el.2015.3456
- 10.1109/JSEN.2016.2606567 · doi:10.1109/jsen.2016.2606567
- 10.1109/LSP.2009.2021378 · doi:10.1109/lsp.2009.2021378
Cited by
Alhamrouni, I., Abdul Kahar, N. H., Salem, M., Swadi, M., Zahroui, Y., Kadhim, D. J., Mohamed, F. A., & Alhuyi Nazari, M. (2024) · Applied Sciences · doi:10.3390/app14146214 · Cited by 217
Tariq, R., Alhamrouni, I., Rehman, A. U., Tag Eldin, E., Shafiq, M., Ghamry, N. A., & Hamam, H. (2022) · Energies · doi:10.3390/en15176468 · Cited by 30
Metadata
- Authors
- Furse, C. M., Kafal, M., Razzaghi, R., & Shin, Y.-J.
- Venue
- IEEE Sensors Journal
- Published
- 2021-01-15
- Volume
- 21
- Issue
- 2
- Pages
- 888-906
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W3016541735
- Cited by
- 296
- References
- 62
- FWCI
- 10.46
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Funders
- U.S. Department of Energy’s Office of Energy Efficiency and Renewable Energy (EERE) through Solar Energy Technologies Office (DE-EE0008169)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fault Diagnosis for Electrical Systems and Power Networks: A Review. https://app.cochat.ai/papers/10.1109/jsen.2020.2987321
- The paper
- Furse, C. M., Kafal, M., Razzaghi, R., & Shin, Y.-J. (2021). Fault Diagnosis for Electrical Systems and Power Networks: A Review. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2020.2987321
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.