The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Distribution system power flow analysis-a rigid approach
Abstract
This approach is oriented toward applications in three phase distribution system operational analysis rather than planning analysis. The solution method is the optimally ordered triangular factorization Y/sub BUS/ method (implicit Z/sub BUS/ Gauss method) which not only takes advantage of the sparsity of system equations but also has very good convergence characteristics on distribution problems. Detailed component models are needed for all system components in the simulation. Utilizing the phase frame representation for all network elements, a program called Generalized Distribution Analysis Systems, with a number of features and capabilities not found in existing packages, has been developed for large-scale distribution system simulations. The system being analyzed can be balanced or unbalanced and can be a radial, network, or mixed-type distribution system. Furthermore, because the individual phase representation is employed for both system and component models, the system can comprise single, double, and three-phase systems simultaneously.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Three-phase cogenerator and transformer models for distribution system analysis
Chen, T.-H., Chen, M.-S., Inoue, T., Kotas, P., & Chebli, E. A. (1991) · IEEE Transactions on Power Delivery · doi:10.1109/61.97706 · Cited by 290
Self-citationChen, M.-S., & Dillon, W. E. (1974) · Proceedings of the IEEE · doi:10.1109/proc.1974.9543 · Cited by 185
Self-citation
Cited by
A direct approach for distribution system load flow solutions
Teng, J.-H. (2003) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2003.813818 · Cited by 1,037
A three-phase power flow method for real-time distribution system analysis
Cheng, C. S., & Shirmohammadi, D. (1995) · IEEE Transactions on Power Systems · doi:10.1109/59.387902 · Cited by 854
A Review on Distribution System State Estimation
Primadianto, A., & Lu, C.-N. (2017) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2016.2632156 · Cited by 652
State estimation for real-time monitoring of distribution systems
Baran, M. E., & Kelley, A. W. (1994) · IEEE Transactions on Power Systems · doi:10.1109/59.336098 · Cited by 474
Distribution system state estimation
Lu, C. N., Teng, J. H., & Liu, W.-H. E. (1995) · IEEE Transactions on Power Systems · doi:10.1109/59.373946 · Cited by 449
Metadata
- Authors
- Chen, T.-H., Chen, M.-S., Hwang, K.-J., Kotas, P., & Chebli, E. A.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 1991-07
- Volume
- 6
- Issue
- 3
- Pages
- 1146-1152
- ISSN
- 0885-8977 (ISSN-L)
- OpenAlex
- W2031454011
- Cited by
- 495
- References
- 2
- FWCI
- 5.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.