Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 264

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Control scheme in hybrid synchronous stationary frame for PWM AC/DC converter under generalized unbalanced operating conditions

Yongsug Suh, Lipo, T.A.·2006·IEEE Transactions on Industry Applications

Abstract

This paper proposes a new control scheme of improved transient response for the pulsewidth-modulation ac/dc converter under generalized unbalanced operating conditions. The overall-bandwidth diminishing filter/functional block for extracting positive and negative sequence components has been avoided by employing dual current regulators in positive- and negative-rotating synchronous frames. The steady-state error due to 120-Hz ac signals has been reduced by employing a resonant-gain path in the current regulator. This paper also proposes simplified current-reference calculation scheme in the regulation of instantaneous active/reactive power. Compared to the previous works, the proposed control method has better transient response in compensation for generalized unbalanced operating conditions (unbalanced input supply and unbalanced input impedances) of wide range while still satisfying unity input power-factor correction and ripple-free dc-output-voltage regulation without adding any external hardware. The proposed control system has been analyzed and tuned based on the ac small signal perturbed model under unbalance. Simulation and experimental results confirm the proposed control method under severe unbalanced operating conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tia.2006.873673

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 264

Metadata

Authors
Suh, Y., & Lipo, T. A.
Venue
IEEE Transactions on Industry Applications
Published
2006-05
Volume
42
Issue
3
Pages
825-835
ISSN
0093-9994 (ISSN-L)
OpenAlex
W2122605594
Cited by
264
References
9
FWCI
12.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Control scheme in hybrid synchronous stationary frame for PWM AC/DC converter under generalized unbalanced operating conditions. https://app.cochat.ai/papers/10.1109/tia.2006.873673
The paper
Suh, Y., & Lipo, T. A. (2006). Control scheme in hybrid synchronous stationary frame for PWM AC/DC converter under generalized unbalanced operating conditions. IEEE Transactions on Industry Applications. https://doi.org/10.1109/tia.2006.873673

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.