The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A new technique for fully autonomous and efficient 3D robotics hand/eye calibration
Abstract
The authors describe a novel technique for computing position and orientation of a camera relative to the last joint of a robot manipulator in an eye-on-hand configuration. It takes only about 100+64N arithmetic operations to compute the hand/eye relationship after the robot finishes the movement, and incurs only additional 64 arithmetic operations for each additional station. The robot makes a series of automatically planned movements with a camera rigidly mounted at the gripper. At the end of each move, it takes a total of 90 ms to grab an image, extract image feature coordinates, and perform camera extrinsic calibration. After the robot finishes all the movements, it takes only a few milliseconds to do the calibration. A series of generic geometric properties or lemmas are presented, leading to the derivation of the final algorithms, which are aimed at simplicity, efficiency, and accuracy while giving ample geometric and algebraic insights. Critical factors influencing the accuracy are analyzed, and procedures for improving accuracy are introduced. Test results of both simulation and real experiments on an IBM Cartesian robot are reported and analyzed.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tsai, R. (1987) · IEEE Journal on Robotics and Automation · doi:10.1109/jra.1987.1087109 · Cited by 5,838
Self-citationRobotics: Control, Sensing, Vision, and Intelligence
Fu, K., González, R. C., & Lee, C. S. G. (1987) · Cited by 1,629
Mathematical elements for computer graphics
Rogers, D. F., & Adams, J. A. (1976) · CERN Document Server (European Organization for Nuclear Research) · Cited by 1,072
Cited by
A tutorial on visual servo control
Hutchinson, S., Hager, G. D., & Corke, P. I. (1996) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.538972 · Cited by 3,528
Visual servo control. II. Advanced approaches [Tutorial]
Chaumette, F., & Hutchinson, S. (2007) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2007.339609 · Cited by 1,032
Analysis of the Accuracy and Robustness of the Leap Motion Controller
Weichert, F., Bachmann, D., Rudak, B., & Fisseler, D. (2013) · Sensors · doi:10.3390/s130506380 · Cited by 913
Hand-Eye Calibration Using Dual Quaternions
Daniilidis, K. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922066213 · Cited by 729
Using vanishing points for camera calibration
Caprile, B., & Torre, V. (1990) · International Journal of Computer Vision · doi:10.1007/bf00127813 · Cited by 711
Metadata
- Authors
- Tsai, R. Y., & Lenz, R. K.
- Venue
- IEEE Transactions on Robotics and Automation
- Published
- 1989-06
- Volume
- 5
- Issue
- 3
- Pages
- 345-358
- ISSN
- 1042-296X (ISSN-L)
- OpenAlex
- W2150382645
- Cited by
- 1,398
- References
- 3
- FWCI
- 12.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.