Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Analysis of the Accuracy and Robustness of the Leap Motion Controller

Open access

Abstract

The Leap Motion Controller is a new device for hand gesture controlled user interfaces with declared sub-millimeter accuracy. However, up to this point its capabilities in real environments have not been analyzed. Therefore, this paper presents a first study of a Leap Motion Controller. The main focus of attention is on the evaluation of the accuracy and repeatability. For an appropriate evaluation, a novel experimental setup was developed making use of an industrial robot with a reference pen allowing a position accuracy of 0.2 mm. Thereby, a deviation between a desired 3D position and the average measured positions below 0.2mmhas been obtained for static setups and of 1.2mmfor dynamic setups. Using the conclusion of this analysis can improve the development of applications for the Leap Motion controller in the field of Human-Computer Interaction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s130506380

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1. Visualization of a (a) Real (using Infrared Imaging) and (b) Schematic View of Leap Motion Controller.
Figure 1. Visualization of a (a) Real (using Infrared Imaging) and (b) Schematic View of Leap Motion Controller.CC BY · PubMed Central
Figure 2. Visualization of the Robot Cell Consisting of the Leap Motion Controller, an Industrial Robot (Kuka Robot KR 125/3) with a Reference Pen: (a) Front View and (b) Schematic View with a Coordinate System.
Figure 2. Visualization of the Robot Cell Consisting of the Leap Motion Controller, an Industrial Robot (Kuka Robot KR 125/3) with a Reference Pen: (a) Front View and (b) Schematic View with a Coordinate System.CC BY · PubMed Central
Figure 3. Visualization of the Basic Test Cases: (a) Positions in the xy-, xz- and yz-Plane and (b) Positions on a Sinus Function Within the xy-Plane.
Figure 3. Visualization of the Basic Test Cases: (a) Positions in the xy-, xz- and yz-Plane and (b) Positions on a Sinus Function Within the xy-Plane.CC BY · PubMed Central
Figure 4. Analysis of the Accuracy and the Repeatability: Deviation between a desired 3D Position and the Measured Positions for a Static Position, (a) xy-Variation; (b) xz-Variation; (c) yz-Variation.
Figure 4. Analysis of the Accuracy and the Repeatability: Deviation between a desired 3D Position and the Measured Positions for a Static Position, (a) xy-Variation; (b) xz-Variation; (c) yz-Variation.CC BY · PubMed Central
Figure 5. Box-and-whisker Plots for different Tool Diameters: d = 3 mm, d = 4 mm, d = 5 mm, d = 6 mm, d = 8 mm, d = 10 mm of the average Deviation concerning (a) x-; (b) y- and (c) z-Axis.
Figure 5. Box-and-whisker Plots for different Tool Diameters: d = 3 mm, d = 4 mm, d = 5 mm, d = 6 mm, d = 8 mm, d = 10 mm of the average Deviation concerning (a) x-; (b) y- and (c) z-Axis.CC BY · PubMed Central
Figure 6. Long Time Measurement: Change of (a) x-, (b) y- and (c) z-Coordinate over Time.
Figure 6. Long Time Measurement: Change of (a) x-, (b) y- and (c) z-Coordinate over Time.CC BY · PubMed Central
Figure 7. Analysis of Accuracy: Deviation between a Desired 3D Position and the Median of the Measured Positions, (a) xy-Plane; (b) xz-Plane; (c) yz-Plane.
Figure 7. Analysis of Accuracy: Deviation between a Desired 3D Position and the Median of the Measured Positions, (a) xy-Plane; (b) xz-Plane; (c) yz-Plane.CC BY · PubMed Central
Figure 8. Analysis of Accuracy of the Measured Positions. The fixed Orientations are marked in red. (a) xy-Plane; (b) xz-Plane; (c) yz-Plane.
Figure 8. Analysis of Accuracy of the Measured Positions. The fixed Orientations are marked in red. (a) xy-Plane; (b) xz-Plane; (c) yz-Plane.CC BY · PubMed Central
Figure 9. Analysis of Accuracy as Bland-Altman Plots for the three axis-aligned movements of the Test Bar of the Robot for a measuring range from −100 mm to 100 mm. (a) x-axis; (b) y-axis; (c) z-axis.
Figure 9. Analysis of Accuracy as Bland-Altman Plots for the three axis-aligned movements of the Test Bar of the Robot for a measuring range from −100 mm to 100 mm. (a) x-axis; (b) y-axis; (c) z-axis.CC BY · PubMed Central
Figure 10. Analysis of Accuracy as Bland-Altman Plots for a Sinus Shaped Motion of the Test Bar of the Robot for a measuring range from − 25 mm to 25 mm. (a) x-Deviation; (b) y-Deviation; (c) z-Deviation.
Figure 10. Analysis of Accuracy as Bland-Altman Plots for a Sinus Shaped Motion of the Test Bar of the Robot for a measuring range from − 25 mm to 25 mm. (a) x-Deviation; (b) y-Deviation; (c) z-Deviation.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Research works printed but not linked: 1

  1. Limited, P. (1977). Exploratory Data Analysis, Addison-Wesley Publishing.

Cited by

See all 913

Metadata

Authors
Weichert, F., Bachmann, D., Rudak, B., & Fisseler, D.
Affiliations
TU Dortmund University (DE)
Corresponding author
Weichert, Frank
Venue
Sensors
Publisher
MDPI AG
Published
2013-05-14
Volume
13
Issue
5
Pages
6380-6393
ISSN
1424-8220 (ISSN-L)
OpenAlex
W2039604658
Cited by
913
References
24
Citations by year
2026: 28 · 2025: 31 · 2024: 31 · 2023: 50 · 2022: 51 · 2021: 84 · 2020: 84 · 2019: 100 · 2018: 111 · 2017: 113 · 2016: 94 · 2015: 80 · 2014: 51 · 2013: 5
FWCI
139.03
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Computer Science › Human-Computer Interaction › Hand Gesture Recognition Systems
  • Physical Sciences › Computer Science › Human-Computer Interaction › Interactive and Immersive Displays
  • Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
Keywords
Leap Motion, hand gesture recognition, 3D position tracking, tracking accuracy, repeatability, human-computer interaction, dynamic tracking

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analysis of the Accuracy and Robustness of the Leap Motion Controller. https://app.cochat.ai/papers/10.3390/s130506380
The paper
Weichert, F., Bachmann, D., Rudak, B., & Fisseler, D. (2013). Analysis of the Accuracy and Robustness of the Leap Motion Controller. Sensors. https://doi.org/10.3390/s130506380

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.