The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Rapid prototyping of an EEG-based brain-computer interface (BCI)
Abstract
The electroencephalogram (EEG) is modified by motor imagery and can be used by patients with severe motor impairments (e.g., late stage of amyotrophic lateral sclerosis) to communicate with their environment. Such a direct connection between the brain and the computer is known as an EEG-based brain-computer interface (BCI). This paper describes a new type of BCI system that uses rapid prototyping to enable a fast transition of various types of parameter estimation and classification algorithms to real-time implementation and testing. Rapid prototyping is possible by using Matlab, Simulink, and the Real-Time Workshop. It is shown how to automate real-time experiments and perform the interplay between on-line experiments and offline analysis. The system is able to process multiple EEG channels on-line and operates under Windows 95 in real-time on a standard PC without an additional digital signal processor (DSP) board. The BCI can be controlled over the Internet, LAN or modem. This BCI was tested on 3 subjects whose task it was to imagine either left or right hand movement. A classification accuracy between 70% and 95% could be achieved with two EEG channels after some sessions with feedback using an adaptive autoregressive (AAR) model and linear discriminant analysis (LDA).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural networks for pattern recognition
(1994) · Choice Reviews Online · doi:10.5860/choice.31-5500 · Cited by 18,538
Haykin, S. (1986) · Cited by 12,603
Neural Networks for Pattern Recognition
Bishop, C. M. (1995) · doi:10.1093/oso/9780198538493.001.0001 · Cited by 12,287
Bellanger, M. (1987) · Signal Processing · doi:10.1016/0165-1684(87)90147-2 · Cited by 2,961
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
EEG analysis based on time domain properties
Hjorth, B. (1970) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(70)90143-4 · Cited by 1,504
Toward Direct Brain-Computer Communication
Vidal, J. J. (1973) · Annual Review of Biophysics and Bioengineering · doi:10.1146/annurev.bb.02.060173.001105 · Cited by 1,287
Motor imagery activates primary sensorimotor area in humans
Pfurtscheller, G., & Neuper, C. (1997) · Neuroscience Letters · doi:10.1016/s0304-3940(97)00889-6 · Cited by 1,051
Self-citationEEG-based discrimination between imagination of right and left hand movement
Pfurtscheller, G., Neuper, C., Flotzinger, D., & Pregenzer, M. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00080-1 · Cited by 904
Self-citationDesigning optimal spatial filters for single-trial EEG classification in a movement task
Müller-Gerking, J., Pfurtscheller, G., & Flyvbjerg, H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(98)00038-8 · Cited by 846
Self-citationPfurtscheller, G., Neuper, C., Schlogl, A., & Lugger, K. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.712230 · Cited by 553
Self-citationMultichannel EEG-based brain-computer communication
Wolpaw, J. R., & McFarland, D. J. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90135-x · Cited by 449
The brain response interface: communication through visually-induced electrical brain responses
Sutter, E. E. (1992) · Journal of Microcomputer Applications · doi:10.1016/0745-7138(92)90045-7 · Cited by 417
Kübler, A., Kotchoubey, B., Hinterberger, T., Ghanayim, N., Perelmouter, J., Schauer, M., Fritsch, C., Taub, E., & Birbaumer, N. (1999) · Experimental Brain Research · doi:10.1007/s002210050617 · Cited by 297
Enhancement of Left-Right Sensorimotor EEG Differences During Feedback-Regulated Motor Imagery
Neuper, C., Schlögl, A., & Pfurtscheller, G. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199907000-00010 · Cited by 225
Self-citationKalcher, J., Flotzinger, D., Neuper, C., Gölly, S., & Pfurtscheller, G. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02520010 · Cited by 168
Self-citationMcFarland, D. J., Lefkowicz, A. T., & Wolpaw, J. R. (1997) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03200585 · Cited by 167
EEG-based communication: prospects and problems
Vaughan, T. M., Wolpaw, J. R., & Donchin, E. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.547945 · Cited by 164
Sensory nerve recording for closed‐loop control to restore motor functions
Popovic, D. B., Stein, R. B., Jovanovic, K. L., Dai, R., Kostov, A., & Armstrong, W. W. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.247801 · Cited by 159
Pfurtscheller, G., Kalcher, J., Neuper, C., Flotzinger, D., & Pregenzer, M. (1996) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95689-8 · Cited by 118
Self-citationSchlögl, A., Flotzinger, D., & Pfurtscheller, G. (1997) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1997.42.6.162 · Cited by 112
Self-citationUsing adaptive autoregressive parameters for a brain-computer-interface experiment
Schlögl, A., Lugger, K., & Pfurtscheller, G. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1997.757002 · Cited by 92
Self-citationGuger, C., Schlögl, A., Walterspacher, D., & Pfurtscheller, G. (1999) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1999.44.1-2.12 · Cited by 44
Self-citationLugger, K., Flotzinger, D., Schlögl, A., et al. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02522476 · Cited by 43
Changes in EEG mean frequency and spectral purity during spontaneous alpha blocking
Goncharova, I. I., & Barlow, J. S. (1990) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(90)90015-c · Cited by 41
Cited by
BCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024
Motor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
Self-citationThe functional significance of mu rhythms: Translating “seeing” and “hearing” into “doing”
Pineda, J. A. (2005) · Brain Research Reviews · doi:10.1016/j.brainresrev.2005.04.005 · Cited by 1,016
How many people are able to control a P300-based brain-computer interface (BCI)?
Guger, C., Daban, S., Sellers, E., Holzner, C., Krausz, G., Carabalona, R., Gramatica, F., & Edlinger, G. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.06.045 · Cited by 652
Self-citationPfurtscheller, G., Müller, G. R., Pfurtscheller, J., Gerner, H. J., & Rupp, R. (2003) · Neuroscience Letters · doi:10.1016/s0304-3940(03)00947-9 · Cited by 548
Self-citation
Metadata
- Authors
- Guger, C., Schlogl, A., Neuper, C., Walterspacher, D., Strein, T., & Pfurtscheller, G.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2001-03
- Volume
- 9
- Issue
- 1
- Pages
- 49-58
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2095607795
- Cited by
- 311
- References
- 25
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.